Adhesive Tape Tack Measurement Device

The adhesive tape viscosity tester measures the peeling force by separating pressure-sensitive adhesive tape from a standard steel plate at a fixed pressure and speed, converting it into viscosity values. It is used for quality inspection of tape adhesion, monitoring adhesive performance during tape production and usage.
Selection
When selecting, consider the thickness range of the adhesive tape being tested to match the instrument's measurement range and roller pressure. Confirm the temperature and humidity control requirements, and check the adjustability of the peel speed. Verify the material of the standard steel plate and the compatibility of the fixtures, and ensure that the data output method meets the recording requirements.

Terms

Standards

Instruments

The equipment tests the initial Tack by short contact between steel ball and adhesive tape sample at a small pressure, adjustable tilt angle 0~ 60 °, rolling ball range 1/32 inch to 1 inch, suitable for a variety of material adhesion evaluation.

$ 240.00

Using 2000g +/- 5g roller load and 300mm/min rolling speed to ensure that the adhesive tape sample is flat and evenly adhered to the standard substrate, in line with CNS-11888 and PSTC-8 design standards.

$ 524.00

The adhesive force of the tape is 4.3N/cm, and the principle of cross-cut method is adopted, which is suitable for adhesion testing. The performance is stable and non-degumming, and the test results are accurate and reliable.

$ 166.00

Tack is good and non-degumming, adhesion reaches 7.6 N/cm, mass performance is stable, suitable for cross-cut adhesion testing, to ensure accurate film integrity assessment.

$ 174.00

Adopting the test principle of inclined rolling ball method, the tilt angle adjustment range is 0~ 40 °, equipped with 32 GCr15 bearing steel balls, and the shape tolerance accuracy exceeds GB/T308 level 40 to achieve accurate initial Tack evaluation.

$ 296.00

With a 5/10 station design and room temperature range, multiple samples can be tested simultaneously, and the adhesion and durability performance can be accurately evaluated through the suspension weight measurement of the displacement or complete disengagement time.

$ 427.00

Equipped with 10-station synchronous test capability, 1000g weight and 1-999999 minute Timer, using SUS #304 steel plate to ensure test accuracy, and automatically recording tape peeling time.

$ 748.00

Adopting the principle of the inclined rolling ball method, the adhesion is measured by the short contact between the steel ball and the sample, the adjustment range of the tilt angle is 0-60 °, and the rolling ball of 1/32 to 1 inch is supported. The width of the test area is 80mm.

$ 338.00

With 5 groups of independent testing capabilities, the temperature control range is from room temperature to 70 ° C, and the hot air circulation method is used to ensure Temperature uniformity.

$ 1284.00

Measurement accuracy of 0.007mm, Graduation of 0.001mm, probe diaMeter Φ 5mm, maximum measurement depth 45mm, suitable for on-site rapid thickness detection.

$ 251.00

Measured value 500N, suitable for tape, PCB, adhesive tape and other materials disbonding force test, supporting the Force Gauge test bench.

$ 89.00

Six-station synchronous test, timing accuracy of 99 hours 59 minutes 59 seconds, using imported proximity switch and laser cross-cut test board to ensure accurate and reliable data, with automatic timing and anti-data loss function.

$ 812.00

Tack testing to assess adhesion by measurement of displacement or peeling time under specified weight. With thermostatic test chamber, multi-national standards are supported and the operation process is clear.

$ 2090.00

Equipped with 1000g weight and 1~ 999999 minute Timer, using SUS #304 steel plate to ensure test accuracy and meet a number of national standards.

$ 414.00

Three stations can be tested simultaneously, with a maximum time of 99 hours, 59 minutes and 59 seconds. Imported proximity switches and laser cross-cut test boards are used to ensure data accuracy and equipment durability.

$ 620.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.