With indoor and outdoor temperature measurement function, the range covers -50 ° C to 99 ° C, the humidity measurement accuracy reaches +/- 5% RH, the maximum and minimum temperature and humidity values can be recorded, and the base and wall mounting are supported.
Using split Sensor design, the temperature range covers -50~ 70 ℃, Humidity Measurement range 20%~ 99% RH, supports ℃/F unit conversion, which is convenient for indoor and outdoor environment monitoring.
Adopting stainless steel frame and 10mm float plate Glass structure, the gas leakage rate is less than 0.5% of the box volume at 1000 Pa per minute, and the surface is smooth and clean without adsorption, ensuring accurate and reliable test data.
It can be tested in the sewage environment, the speed range is 0.01-10 m/s, the error is less than or equal to 1.5%, the measuring Rod positioning measurement method is adopted, the structure is simple and light, the Degree of automation is high and stable and reliable.
Temperature range -5~ 99.99 ℃, Temperature Fluctuation +/- 0.05 ℃, Temperature resolution 0.01 ℃, support internal and external circulation system, Tank volume 5/6L, provide a stable environment for temperature sensitive experiments.
It can simultaneously detect 7 paraMeters such as PM2.5, formaldehyde, and TVOC, with an accuracy of +/- 10%. It is equipped with a 2.8-inch true color screen to display real-time trend charts, and supports 5000 data records and dual national standard selection.
Temperature range RT + 3~ 65 ℃, accuracy +/- 0.3 ℃, equipped with ultraviolet sterilization lamp and deoxygenation catalyst, can quickly form an anaerobic environment and maintain more than 12 hours, the operation room is made of stainless steel, flexible and convenient to use special gloves.
Using irreversible discoloration technology, Measuring temperature 80 ℃, 15 * 15mm square design, single piece single temperature measurement, suitable for indoor environment use.
Vacuum environment significantly reduces the boiling point of liquid, suitable for heat-sensitive substances; drying Temperature range RT + 50~ 200 ℃, Vacuum Level < 133Pa; inert conditions prevent oxide explosion, powder sample stability does not move.
Using double-decked Vacuum Glass observation window and SUS304 stainless steel inner box, temperature control accuracy +/- 0.5 ℃, support programmed test and multi-stage programming, with Data storage and communication functions to meet the demanding environment testing needs.
Using irreversible discoloration technology, temperature measurement accuracy to 70 ℃, square 15 * 15mm small size design, suitable for indoor environment monitoring, easy and reliable operation.
Using irreversible discoloration technology, accurate measurement of 60 ° C temperature, 15 * 15mm square design for easy observation, suitable for indoor environment use.
Adopting double-decked Vacuum Reinforced Glass observation window and SUS304 stainless steel inner box, the temperature control accuracy reaches +/- 0.5 ℃, supports program test and Data storage function, and meets the strict environment Reliability verification requirements.
Maximum temperature of 1700 ℃, Furnace volume of 12 liters, using silicon molybdenum Rod heating and aluminum oxide fiber Furnace to ensure uniform heating and durability, support inert or reducing gas environment, suitable for high temperature material processing.
Using irreversible discoloration method, Measuring temperature 70 ℃, circular design diaMeter 1.5 cm, single temperature per piece, suitable for indoor environment use, no anti-fouling protective film.