Laboratory Vacuum Planetary Mixer

The laboratory vacuum planetary mixer mixes materials in a vacuum environment through the planetary motion of revolution and rotation. This structure allows the materials to tumble without dead corners while removing bubbles. It is used for the uniform mixing and debubbling of high-viscosity materials such as coatings and inks.
Selection
When selecting, consider the viscosity of the material to match the motor power, ensure the vacuum level meets degassing requirements, and choose a stirrer blade material that is corrosion-resistant. Select the model based on the container capacity, observe the durability of the sealing components, and configure temperature control as needed.

Terms

Standards

Instruments

Adopt biaxial planetary motion structure, revolution 0-70rpm and rotation 0-80rpm adjustable, equipped with automatic wall scraping device to achieve no dead point mixing, Total Power 6.75kw to meet a variety of material handling needs.

$ 7303.00

Adopting a planetary two-way swirl/spin structure, the mixing arm runs in reverse with the basket to achieve rapid mixing, with a maximum load of 300g and a speed range of 400-2800rpm. The equilibrate is quiet and can be operated directly in the syringe or test bottle.

$ 5237.00

Adopting a six-axis planetary stirring structure, including two sets of high-speed dispersers and low-speed twist paddles, with a revolution speed of 0-80rpm and a rotation speed of 0-3800rpm, it can achieve no dead-angle mixing, with a Vacuum Level of -0.098MPa, suitable for materials with a viscosity of up to 1 million mPa · s.

$ 14274.00

Adopting the principle of planetary motion, the grinding time only takes 15-20 minutes, the discharge particle size reaches 0.1 micron, supports dry grinding, wet grinding, vacuum grinding and other methods, and is equipped with a 200CFM heat dissipation system and a low center of gravity design to ensure stable operation.

$ 1573.00

360 degree tumbling structure combined with planetary disk swirl/spin, maximum Processing capacity 80L, minimum discharge particle size 0.1μm, support dry grinding, wet grinding, vacuum and other grinding methods, equipped with a variety of materials ball mill Tank to adapt to different samples.

$ 14482.00

The 360-degree tumbling structure combined with planetary disk motion, the maximum Processing capacity is 40L, and it supports various methods such as dry grinding and wet grinding vacuum grinding, which can reach 0.1 μm discharge particle size and improve grinding uniformity and efficiency.

$ 8614.00

Using the principle of planetary motion, the grinding time is only 15-20 minutes, and the discharge particle size is up to 0.1 micron; it supports dry grinding, wet grinding, vacuum grinding and other methods, equipped with four-station design, Rotation speed 800rpm, suitable for various sample characteristics.

$ 1499.00

360 ° tumbling structure combined with planetary disk swirl/spin, maximum Processing capacity 16L, support dry and wet grinding vacuum grinding, can reach 0.1 μm discharge particle size, with a variety of ball mill Tank material and grinding mode selection.

$ 5798.00

Six-axis planetary stirring structure, equipped with high-speed disperser and low-speed twist paddle, Rotation speed 0-90rpm, dispersion Rotation speed 0-3800rpm, can achieve no dead angle mixing of materials, and has an online temperature measurement system, temperature error less than 1 ℃.

$ 82694.00

The total grinding volume is 100L, and the maximum can be configured with 4 25L ball milling cans; with dry grinding, wet grinding, vacuum grinding and other grinding methods; using the principle of planetary motion, grinding ball high-speed collision friction material; the core components choose high-quality inverters and motors, stable and durable performance.

$ 11841.00

Adopting the principle of planetary motion, the particle size of grinding discharge can reach 0.1 μm, supporting dry grinding, wet grinding, vacuum grinding and other methods, with four stations and 800rpm Rotation speed, safe and stable operation.

$ 1866.00

The rectangular vacuum Chamber improves space utilization, Vacuum Level up to 133Pa, is equipped with double-decked tempered Glass doors for easy observation, supports program control of heating and vacuum holding time, and improves processing conformity.

$ 2939.00

The built-in vacuum pump realizes 0~ -80kPa Vacuum Level, the fully transparent vacuum Chamber can hold 12 samples, the program control supports 80 sets of paraMeter storage, and the vacuum cycle operation is automatically completed.

$ 4108.00

360 ° tumbling structure combined with planetary disk swirl/spin, maximum Processing capacity 12L, minimum discharge particle size 0.1μm, support a variety of grinding methods and materials, easy operation and power-off protection function.

$ 4213.00

Vacuum chuck area of 300 * 400mm, equipped with 150W vacuum pump, aperture 0.8mm to ensure uniform adsorption, improve Spreader accuracy and Stability.

$ 638.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Vacuum adsorption coating machine solves the flatness challenge in the transfer of ultra-thin graphene films.
The vacuum adsorption coating machine transfers graphene films smoothly onto target substrates through controlled negative pressure, solving issues such as wrinkling, tearing, and contamination often encountered with traditional methods.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Vacuum adsorption coating machine is used for the coating of proton exchange membrane fuel cell electrodes.
This article introduces the application of vacuum adsorption coating machines in the coating of proton exchange membrane fuel cell electrodes.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Sealing Tester Measures Leak Points in Flexible Packaging Bags.
This article introduces how a seal tester detects air leak points in flexible packaging bags. It primarily identifies leaks through changes in pressure or vacuum, and the operation involves preparing samples, setting parameters, and conducting standardized testing.
Vacuum adsorption coating of perovskite precursors on flexible substrates.
This article introduces the process of vacuum adsorption coating for perovskite precursors on flexible substrates.
Vacuum adsorption coating table solves the problem of film substrate wrinkling.
The vacuum adsorption coating platform uses a microporous array connected to a vacuum system beneath the tabletop to create a pressure difference, tightly adsorbing the film substrate. This ensures it remains flat during the coating process, preventing wrinkles that could lead to uneven coating.
How to Utilize a Vacuum Adsorption Coating Machine to Solve the Slippage Issue During Coating on Flexible PET Substrates
The vacuum adsorption coating machine stabilizes the flexible PET substrate on the coating platform through negative pressure, effectively addressing the slipping issue during the coating process. Slipping is primarily caused by factors such as the smooth surface of PET, insufficient friction, and interference from coating pressure, which can lead to uneven coatings.
Application of Vacuum Heating Integrated Coating Machine in the Preparation of High-Temperature Curing Coating Samples
This article introduces the application of the vacuum heating integrated film coater in the preparation of samples for high-temperature curing coatings. The equipment reduces bubbles in the coating by creating a vacuum environment and integrates programmable heating and curing functions, enabling precise temperature control to promote the chemical cross-linking of the coating and form a uniform film.
Negative Pressure Method Sealing Tester for Detecting Leakage in Food Packaging
The negative pressure method seal tester creates a pressure difference inside and outside the packaging by evacuating air to detect leaks in food packaging. If there is a leak in the packaging, water will enter the packaging or produce continuous bubbles under the pressure difference, thereby determining the seal integrity. The test requires controlling parameters such as vacuum level and time, and should be conducted in accordance with relevant standards.
Principle and Application of Vacuum Decay Leak Testing Equipment
The vacuum decay leak tester is a non-destructive detection device that quantitatively detects leaks by monitoring minute pressure changes in the test chamber after vacuum evacuation.
Key Points for Operating Vacuum Adsorption Coating Machines on Flexible Substrates
Vacuum adsorption coating technology is a key process in flexible electronics, functional coatings, and the preparation of new materials. This technique uses vacuum negative pressure to ensure that flexible substrates are smoothly and evenly adsorbed onto the coating platform. Combined with precision coating, it effectively reduces defects such as wrinkles and bubbles, thereby enhancing the uniformity and consistency of the coating.
Detailed Explanation of Laboratory Vacuum Adsorption Platform: Flatness is the Cornerstone of Successful Coating
The vacuum adsorption platform is a key device in coating experiments, which stabilizes the substrate by negative pressure adsorption, providing a reference plane for coating. The flatness of the platform surface is crucial, as even minor deviations can lead to defects such as uneven coating thickness or the appearance of streaks.
What are the differences between a vacuum oven and a conventional oven?
The main difference between a vacuum oven and a conventional oven lies in their working pressure. Conventional ovens operate at atmospheric pressure, heating through air convection, making them suitable for routine drying tasks. In contrast, vacuum ovens are evacuated to low pressure to reduce air presence, primarily relying on thermal radiation for heat transfer. This makes them ideal for processing heat-sensitive, oxidation-prone materials or those requiring thorough drying.