Hydrogen ion Detector

A hydrogen ion detector forms a galvanic cell using a glass electrode and a reference electrode to measure the potential difference in a solution, which is then converted to pH. It is used to monitor the acidity or alkalinity of liquids, controlling reaction conditions and product quality in fields such as chemical engineering, environmental protection, and food production.
Selection
When selecting, consider the measurement accuracy and range to match the sample characteristics. The electrode material must be corrosion-resistant, and check for temperature compensation functionality. Compare the calibration stability across different brands, confirm that the protection rating is suitable for the usage environment, and evaluate maintenance costs and consumable supply.

Terms

Standards

Instruments

Electrochemical sensor, detecting phosphating hydrogen gas, range 0-20ppm, resolution 0.1ppm, with sound, light, vibration triple alarm, IP65 Protection Rating, suitable for harsh environments.

$ 235.00

Industrial grade Sensor, detection of phosphating hydrogen 0-20ppm range, resolution of 0.1ppm, Response Time less than 30 seconds, explosion-proof structure to ensure safe operation of hazardous environment, support a variety of Gas detection.

$ 251.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 1% F. S, suitable for a variety of Ion concentration detection.

$ 864.00

Electrochemical sensor technology, detection accuracy +/- 2% F. S, Response Time less than 10 seconds. With intrinsically safe circuit design and explosion-proof certification, support a variety of signal output and remote monitoring functions, adapt to various industrial environments.

$ 441.00

Concentration 1000ppm of copper ion standard solution, PTFE bottle Encasement, capacity 480mL, suitable for daily ion calibrating applications.

$ 135.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 0.5% F. S, suitable for a variety of Ion concentration detection.

$ 864.00

Universal ion standard solution concentration 1000ppm, suitable for daily ion calibrating, PTFE bottle Encasement, capacity 480mL, to ensure calibrating accuracy and Stability.

$ 135.00

Imported Electrochemical sensor, Response Time less than 10 seconds, detection accuracy +/- 2% F.S. With intrinsically safe circuit design and IP66 Protection Rating, support a variety of signal output and remote monitoring, automatic zero tracking to prevent drift.

$ 630.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and explosion-proof certification, support RS485 and 4-20mA standard signal output, suitable for real-time monitoring of various industrial environments.

$ 630.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ElectRode, Measurement accuracy +/- 0.5% F.S., can store 1000 sets of data, suitable for a variety of Ion concentration detection.

$ 864.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, expands memory to store 1000 sets of data, Measurement accuracy of +/- 1% F.S.

$ 864.00

Measurement range of 1~ 2 × 10, using BNC plug design, matching pH and ion Meter, easy operation and fast Response, suitable for accurate Ion concentration detection.

$ 191.00

General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.

$ 135.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 1% F.S.

$ 864.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds. With Intrinsic Safety (IS) design and a variety of signal output interfaces, support remote monitoring and data transmission, strong anti-interference ability Stability.

$ 441.00

Articles

Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Heating and blade coating of gel electrolyte films for zinc-ion batteries.
This article introduces the heating doctor-blade coating method for preparing gel electrolyte films in zinc-ion batteries. The method involves spreading a slurry onto a substrate using a doctor blade, followed by heating to evaporate the solvent and form a film.
Uniform coating of lithium-ion battery cathode slurry on aluminum foil.
This article primarily discusses how to uniformly coat the positive electrode slurry onto aluminum foil in lithium-ion battery manufacturing. The slurry itself exhibits shear-thinning properties, making it suitable for coating applications.
The film coater achieves controllable coating of lithium-ion battery anode slurry on copper foil.
This article explores how coating machines control the application process of the negative electrode slurry onto copper foil in the manufacturing of lithium-ion batteries.
The film coater is used for experimental-grade uniform coating of lithium-ion battery cathode slurry on aluminum foil.
This article explores the technique of uniformly coating lithium-ion battery cathode slurry on aluminum foil using a laboratory-grade coating machine.
Heating coating machine is used for the doctor-blade coating of gel electrolyte films in zinc-ion batteries.
This article introduces the blade coating process for preparing gel electrolyte films for zinc-ion batteries using a heated coating mechanism. By controlling parameters such as temperature, coating speed, and gap height, this method enables the fabrication of films with uniform thickness and smooth surfaces.
BET surface area analyzer evaluates the pore structure of ion exchange resins
This article introduces how to use a specific surface area analyzer to evaluate the pore structure of ion exchange resins.
Automatic Potentiometric Titration for Rapid Detection of Chloride Ion Content in Cement
This article introduces a method for rapidly detecting the chloride ion content in cement using an automatic potentiometric titrator. Excessive chloride ions can corrode steel reinforcement and affect the lifespan of concrete, making accurate detection crucial.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.