Multifunctional gas chromatography instrument

The multifunctional gas chromatograph carries the sample through the chromatographic column using a carrier gas, achieving separation by leveraging the differential adsorption capabilities of the stationary phase for various components. The detector converts concentration signals into electrical signals. It is used to detect volatile organic compound content, solvent residues, and more, enabling qualitative and quantitative analysis in fields such as chemical engineering, environmental protection, and food safety.
Selection
Select the type of chromatographic column based on the boiling point and polarity of the substance to be detected, choose detectors such as FID or ECD according to detection limit requirements, determine the injection method based on the sample form, decide on the automatic injection function based on analysis throughput needs, and consider laboratory space and carrier gas supply conditions to determine instrument size and gas source configuration.

Standards

Instruments

Maximum 4 kinds of gas simultaneous detection, integrated temperature and Humidity compensation, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.

$ 693.00

250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.

$ 127.00

Support 4 kinds of gas detection at the same time, integrated Humidity monitoring function, dual temperature Humidity compensation design, with 10 Meters visual distance high definition color screen, Protection Rating up to IP66, Operating temperature range -40~ 55 ℃.

$ 819.00

Frequency range starts to 300 times/minute stepless speed regulation, swing amplitude 20mm, low noise and low power consumption, suitable for a variety of experimental environments.

$ 451.00

Maximum load 5KN, suitable for a variety of material testing, multi-functional design can be adapted to different samples, stable and reliable clamping, to meet the laboratory's diverse mechanical properties testing needs.

$ 332.00

Operating temperature up to 1400 ℃, Furnace volume of 12 liters, using silicon carbon Rod heating element and double chill down system, support inert gas and reducing gas environment material sintering process.

$ 4285.00

Cuboid studios improve volume utilization and reduce drying time by more than 40% compared with traditional equipment; stainless steel studios and double-decked Glass doors, Vacuum Level up to 133Pa, support inert gas environment operation.

$ 975.00

Support simultaneous detection of 4 gas paraMeters, integrated temperature and Humidity detection function, with Internet of Things remote monitoring capability, Response Time T90 meets national standards, Protection Rating up to IP66, adapt to -40~ 55 ℃ working environment.

$ 328.00

With double Tank grinding ability, vibration speed 60-1800rpm, discharge particle size 5~ 10μm, support low temperature treatment of heat sensitive materials and low liquid nitrogen consumption, can handle more than 10 samples at a time.

$ 5737.00

Using 60-1800rpm vibration speed, the discharge particle size can reach 5~ 10μm, support dry grinding, wet grinding and low temperature grinding, suitable for heat-sensitive materials and minimal liquid nitrogen consumption, can handle more than 10 samples at a time.

$ 5610.00

With 60-1800R/min vibration speed and 1-30Hz Frequency range, support dry grinding, wet grinding and low temperature grinding, can handle feed ≤ 8mm sample to 5~ 10μm particle size, suitable for thermal materials and low liquid nitrogen consumption.

$ 5665.00

Operating temperature of 1400 ℃, Furnace volume of 36 liters, aluminum oxide fiber Furnace and double chill down system, support material sintering process in inert gas environment.

$ 4914.00

The horizontal and vertical combined oscillation mode is adopted, and any mode can be used alone. The stepless speed regulation range starts to 300 times/min, and the pendulum amplitude is 20mm, which has the characteristics of low noise and long life.

$ 490.00

Dual gas source dynamic Gas chromatography, CG, 4 station design test efficiency, each sample only 5-7 minutes, measurement error ≤ +/- 1%, high Sensitivity Detector to ensure accurate and reliable data.

$ 10562.00

Support 4 kinds of gas simultaneous detection, integrated temperature Humidity monitoring, physical + software double revisit Humidity compensation, with zero automatic correction function, Response Time T90 ≤ national standard, detection accuracy ≤ +/- 3% FS.

$ 1050.00