Ammonia Leak Concentration Detector

Ammonia gas leak concentration detectors use electrochemical sensors to detect changes in the concentration of ammonia molecules in the air. When ammonia reacts with the electrolyte inside the sensor to generate an electrical signal, the instrument displays the concentration value and triggers an alarm. They are used in places such as cold storage facilities and chemical plants to monitor pipeline leaks and air safety.
Selection
Ensure the detection range covers 0-100 ppm during selection, with audible and visual alarms and data logging capabilities. The sensor lifespan should exceed 2 years. Consider the explosion-proof rating to suit the on-site environment, perform regular calibration to ensure accuracy, and compare response times and maintenance costs across different brands.

Terms

Standards

Instruments

Frequency range 20KHz to 100KHz, Sensitivity indicated by LED and sound, weight of only 140 grams for portable, suitable for a variety of gas and air leak detection scenarios.

$ 301.00

Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.

$ 209.00

Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.

$ 1806.00

250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.

$ 127.00

Colorimetric measurement based on Nasler method, Measurement range 0.00-10 mg/L, providing 100 tests, accurate determination of ammonia nitrogen concentration by Color intensity change.

$ 212.00

Electrochemical sensor technology, detection accuracy +/- 2% F. S, Response Time less than 10 seconds. With Intrinsic Safety (IS) design, support RS485 and 4-20mA dual output, equipped with 2.5 inch color screen display real-time concentration, Temperature Humidity paraMeters.

$ 630.00

Colorimetric measurement using Nessler method. Measurement range is 0.0~ 100.0 ppm ammonium. 100 tests are provided. Yellow shade is generated for concentration determination.

$ 257.00

Electrochemical sensor, Response Time ≤ 20 seconds, range 0-100ppm, resolution 0.1ppm, waterproof, dustproof and explosion-proof design, support sound and light vibration triple alarm and Sensor fault self-check function.

$ 202.00

Colorimetric measurements using the Nessler method are fast. Measurement range is 0.0 to 100.0 mg/L, providing 300 tests, ensuring accurate determination of ammonium Ion concentration and supporting unit conversion.

$ 567.00

Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.

$ 110.00

Pump suction sampling, Response Time T90 ≤ 20 seconds, detection accuracy ≤ +/- 3%, equipped with dust Filter, suitable for harsh environments, support Data storage 120000 groups.

$ 507.00

Using pump-suction sampling and imported Electrochemical sensor, Response Time ≤ 20 seconds, detection accuracy ≤ +/- 3%, support 1-4 Sensor expansion, Protection Rating IP65 for harsh environments.

$ 527.00

Electrochemical sensor for rapid Response, detection accuracy of +/- 2% F. S, with Intrinsic Safety (IS) design and a variety of signal output interfaces, support remote monitoring and data transmission, adapt to -30~ 50 ℃ working environment.

$ 888.00

The MCU chip is used to achieve low power consumption operation, the detection error is ≤ +/- 3% F. S, the Response Time is ≤ 30 seconds, and it supports a variety of signal output and remote alarm functions to meet the needs of complex industrial applications.

$ 267.00

Electrochemical sensor for rapid Response, detection accuracy of +/- 2% F. S, with RS485 and 4-20mA output, explosion-proof design for hazardous environments, support for remote monitoring and multi-system compatibility.

$ 630.00

Articles

How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Selection Basis for Karl Fischer Titration: Volumetric vs. Coulometric Methods
There are two methods for Karl Fischer moisture titrators: volumetric and coulometric. The volumetric method calculates moisture by measuring the volume of a reagent with a known concentration that is consumed, making it suitable for samples with higher moisture content, such as those in the range of a few thousandths or more.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Valley Beater in Pulp Laboratory Beating
The Valley beater is a device used in laboratories to simulate industrial beating processes. It modifies the morphology of pulp fibers through mechanical action, thereby influencing paper properties. During operation, parameters such as beating pressure, pulp consistency, and beating time must be controlled, with the beating degree serving as a quantitative measure of the effect.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
The role of a reflection densitometer in controlling printing ink concentration.
The reflection densitometer measures the light reflectance of the ink layer and converts it into a density value, thereby objectively reflecting the thickness and concentration of the ink layer. In printing, it is used to monitor solid density, ensuring stable ink supply, replacing subjective judgment, and enabling data-driven control.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
Application of Salt Spray Test Chambers in Corrosion Resistance Testing of Automotive Components
The salt spray test chamber simulates a salty and humid environment to accelerate the testing of the corrosion resistance of automotive components. Its principle is based on electrochemical corrosion, allowing for the control of key parameters such as salt concentration and temperature.
If the standard disintegrator procedure for fiber dissociation is not done correctly, the first step of paper strength testing is already compromised.
Fiber disintegration is the first step in paper strength testing. If the operation is not standardized, such as inaccurate concentration, excessive time, or incorrect rotational speed, it can lead to fiber breakage or uneven dispersion, resulting in inaccurate strength data for the prepared hand sheets.