High Temperature Thermostatic Circulator

The high-temperature constant temperature circulating bath uses electric heating and a circulation pump to maintain a stable high temperature and uniform flow of the liquid inside the bath. It is used in scenarios such as constant temperature heating of laboratory samples, temperature control for reactors, and material testing to ensure temperature consistency.
Selection
When selecting, consider that the temperature range must cover experimental requirements, the temperature control accuracy should match application standards, the tank capacity should accommodate sample sizes, the material's corrosion resistance should align with the characteristics of the medium, safety protection features should be comprehensive, and the operation interface should be simple and reliable.

Terms

Standards

Instruments

With heating and cooling functions, Temperature range -20~ 100 ℃, Fluctuation +/- 0.05~ 0.1 ℃, can be 10-stage program control, to achieve timing thermostatic, heating and cooling.

$ 1372.00

With heating and cooling functions, Temperature range -10~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, support 10-stage program control and external communication, pump Flow rate 12L/min, suitable for internal and external circulation applications.

$ 1146.00

Adopt proportional refrigeration and PID control technology, support 30-stage program control, Temperature Fluctuation +/- 0.05K, with multiple safety protections such as water shortage protection and overheating and overflow, and the pump Flow rate reaches 12L/min.

$ 1519.00

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, using proportional refrigeration technology and PID control, support internal and external circulation and programmed operation, with low liquid level and over temperature protection, suitable for a variety of application environments.

$ 2287.00

Adopt proportional refrigeration and PID control technology, temperature control accuracy of 0.05K, support 30 program settings, equipped with maintenance-free pressure pump and multiple Safety protection system, working noise is less than 45 decibels.

$ 2163.00

With proportional refrigeration and PID control technology, temperature control accuracy of 0.05K, support 30-stage program control. Adopt maintenance-free pressure pump, maximum Flow rate 22L/min, integrated multiple Safety protection system.

$ 2050.00

Temperature range -20 ℃ to 150 ℃, equipped with pressure/suction pump and Pt100 Sensor, supports multi-stage program control and external temperature sensor, with hardware over-temperature protection and multiple safety modes.

$ 977.00

Temperature range -20 ℃ to 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1K, equipped with pressure/suction pump and hardware over-temperature protection, supports multi-stage program control and external Sensor interface.

$ 909.00

Can work at room temperature to 300 ℃ range, using high temperature centrifugal jet circulation pump, head up to 5 Meters, equipped with PID automatic temperature control, digital resolution 0.01 ℃, Temperature Fluctuation +/- 0.05 ℃, domestic circulation system to achieve a high degree of uniform temperature field.

$ 914.00

It can precisely control the temperature in the range of room temperature to 300 ° C, Temperature Fluctuation +/- 0.05 ° C, equipped with high temperature centrifugal jet circulation pump, head 5 Meters, support the internal and external circulation system, and achieve a highly uniform temperature field.

$ 672.00

Temperature range -20 ℃ to 150 ℃, Temperature Fluctuation +/- 0.05~ 0.1K, using pressure/suction pump and Pt100 Sensor, support multi-stage program control and external Communication interface.

$ 1090.00

Temperature range -20 ℃ to 150 ℃, temperature control accuracy +/- 0.05~ 0.1K, equipped with pressure/suction pump and Pt100 Sensor, support multi-stage program control and external temperature sensor.

$ 887.00

Temperature range Room temperature to 300 ℃, Temperature Fluctuation +/- 0.05 ℃, support water-oil dual-use medium; High temperature centrifugal pump head 5 Meters, to achieve uniform temperature field inside and outside circulation, built-in multiple Safety protection devices.

$ 1166.00

Adopt pressure suction pump to automatically adapt to external load, maximum Flow rate 12L/min; support multi-stage program control, each section is up to 999 hours; with hardware over-temperature protection and liquid level protection functions, in line with safety standards.

$ 841.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Melt flow index tester measures the processing fluidity of high-temperature engineering plastics.
This article introduces how a melt flow indexer measures the processing fluidity of high-temperature engineering plastics. It first explains the working principle of the instrument, which involves measuring the rate at which molten plastic passes through a standard die under specific temperature and pressure conditions to obtain the melt flow rate value.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.