Ultra-microBalance

Ultra-micro balances operate on the principle of electromagnetic force compensation, calculating minute mass by measuring changes in current. They are used for weighing samples in the range of 0.1 μg to 0.1 mg and play a role in microscopic measurements such as material surface adsorption and mass per unit length of fibers.
Selection
When selecting, pay attention to the matching of the actual weighing range and division value requirements, and check the environmental vibration and airflow isolation devices. Consider the compatibility of sample containers, and confirm the temperature stability compensation function. Verify the traceability documents of calibration weights, and evaluate whether the operation interface aligns with usage habits.

Terms

Standards

Instruments

With 18.25MΩ · cm ultra-pure water output and 20L/H water pRoduction capacity, 7-inch color touch screen to achieve animation control, support for water inlet, RO water, UP water three-way water quality online monitoring and automatic reminder of consumables.

$ 3753.00

With 18.2MΩ · cm ultra-pure water output and 10L/H water pRoduction capacity, 7-inch touch screen real-time display of water quality paraMeters, support for automatic circulation and consumables reminders, improve experimental efficiency and water quality Reliability.

$ 3491.00

With 80L/H water pRoduction capacity and 18.2MΩ · cm ultra-pure water quality, it supports regular automatic circulation and consumable life monitoring. It can disinfect and display three-way water quality with one click, prolong the service life of the ultra-pure water bag, and achieve efficient online monitoring.

$ 2834.00

12.7Mm ultra-thin body and 250g lightweight design for easy portability; CAL-CHECK system can prompt ElectRode contamination and buffer information; Support 1000 sets of Data storage and USB interface transmission; Automatically identify ElectRode type and enter Measurement mode, suitable for a variety of environments.

$ 848.00

Temperature range -50 to 300 ° C, Response Time of only 4 seconds, equipped with replaceable ultra-fast Response stainless steel penetration Probe, with CAL Check ™ Adjustment and battery error prevention system to ensure accurate and reliable measurement.

$ 309.00

Viscosity range 0.6~ 6000000mPa · s, repRoducibility +/- 0.5% F. S, supports continuously variable speed and liquid crystal display of various paraMeters, suitable for ultra-low viscosity sample measurement.

$ 1255.00

Equipped with 18.25MΩ · cm ultra-pure water quality and 100L/H water pRoduction capacity, 7-inch color touchscreen displays three-way water quality and temperature in real time, supports consumables failure reminder and automatic circulation system to ensure stable water quality.

$ 5195.00

Using eddy Current thickness measurement principle, equipped with ultra-thick coating special Probe, Measurement range 0~ 13000 μm, error +/- 3%, can read more than 180 data per minute, support 250,000 Measured value storage.

$ 1760.00

Using clutter flying technology implementation of 0.15mm ultra-thin parts measurement, the highest resolution of 0.001mm, support through coating measurement and Bluetooth communication, with voice broadcast and LED backlight function.

$ 993.00

Using 0.06mm ultra-fine steel wire, soft bristles, effective cleaning of anilox rollers and Mayer Rods, to avoid surface damage, handmade to ensure mass.

$ 146.00

Response Time of only 4 seconds, temperature range of -50.0 to 300 ℃, equipped with replaceable ultra-fast Response K stainless steel penetration Probe, with CAL Check ™ calibrate inspection and automatic shutdown function.

$ 309.00

Adopt stepper motor direct drive to ensure accurate speed, equipped with RTD temperature probe real-time monitoring, Measurement accuracy of +/- 1% F. S, with ultra-low viscosity adapter to extend Measurement range to 1mPa · s.

$ 1075.00

Using stepper motor direct drive to ensure accurate speed, Measurement range 1~ 2000000mPa · s, with RS232 interface and RTD temperature probe, support ultra low viscosity liquid measurement.

$ 1180.00

Adopt 16-bit microcomputer processor and stepper motor drive to achieve continuously variable speed of 0.1~ 200rpm; standard L0 ultra-low viscosity adapter, only 25~ 30mL sample can accurately measure ultra-low viscosity, repRoducibility up to +/- 0.5% F.S.

$ 2110.00

Ultra-high rigidity gantry frame structure, Accuracy grade 0.5, maximum test force 20kN, equipped with piecewise linear correction and high-speed processor to ensure High Accuracy and Stability, support a variety of deformation measurement.

$ 4850.00

Articles

A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Summary of Balance Selection for Different Application Scenarios
This article discusses how to choose a balance based on usage needs. First, you need to understand the basic parameters of a balance, such as its maximum capacity and precision.
Grade classification of balances based on different repeatability indicators
The repeatability of a balance refers to the consistency of multiple weighing results for the same load under identical conditions, which is a key indicator for evaluating the performance of a balance. It is typically expressed as the standard deviation or range, with smaller values indicating greater stability and reliability of the balance.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Selection Considerations for Balances with Different Weighing Pan Materials
When selecting the material of the balance weighing pan, it is necessary to comprehensively consider the sample properties, measurement environment, and operational requirements.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Which one to choose: built-in calibration or external calibration balance?
This article primarily compares the two calibration methods for balances: internal calibration and external calibration.
Differences in the Selection of Analytical Balances and Precision Balances
Analytical balances and precision balances are both high-precision weighing instruments commonly used in laboratories, but they differ primarily in terms of accuracy and application scenarios.
Repetibility Test Method and Weights for Semi-micro Balances
This article discusses the method for repeatability testing of semi-micro balances and the use of weights. Repeatability refers to the consistency of the balance's results when weighing the same object multiple times under the same conditions, which is crucial for the reliability of experimental data.
Laboratory Application Scenarios of Milligram Precision Balances
The milligram precision balance can accurately weigh up to 0.001 grams, primarily utilizing electromagnetic force compensation technology, and its performance is related to parameters such as repeatability and linearity error.
Analysis of Causes for Excessive Repetition Error in Microbalances
Microbalance repeatability out-of-tolerance refers to the situation where the results of multiple weighings of the same object exceed the allowable range of variation.
Oven combined with analytical balance for determination of solid content
This article introduces a method for determining the solid content of samples in the laboratory by combining an oven and an analytical balance.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.