Fully pneumatic design ensures stable operation, adjustable spray gun settings for precise atomization and film thickness control, and magnetic panel supports multiple substrate tests.
Equipped with double spray guns to achieve uniform lame plating, the lifting range of the spray gun is adjustable from 10-500mm, the integrated air filtrate adjustment system supports magnetic or vacuum panel fixing, and improves the coating test Repeatability.
With intelligent acceleration function, the stirring speed is adjustable from 0 to 1250rpm, the maximum stirring capacity is 2 liters, the Timer Range is 0 to 999 minutes, and the stainless steel panel is durable and easy to clean.
Support 0.1-1 steel plate and 0.1-2 Aluminum Panel test, can complete 0T to 1T multi-stage bending, equipped with pliers pressing device and tape adhesion inspection function, to meet the standard bending test process.
Adapted to NS series ColoriMeter, it can measure liquid, sauce and powder samples, realize color data collection of various forms of materials, and expand the application range of the instrument.
Thickness 0.5mm fillet edge no burr design, surface with anti-rust oil to prevent oxidation, suitable for adhesion, Hardness, Impact and other coating performance test.
Film thickness 0.5mm, rounded edge design without burr, surface with anti-rust oil, suitable for coating adhesion, hardness, Impact and other performance testing experiments.
Film thickness 0.5mm, rounded edges without burr design, surface with anti-rust oil, suitable for adhesion, hardness, Impact and other paint performance testing experiments.
Film thickness 0.5mm fillet edge no burr design, with anti-rust oil to protect the surface, suitable for adhesion, hardness and other paint performance testing experiments, about 120 pieces per kilogram Encasement.
Using D/8 lighting system, Inter-instrument Agreement Delta E * 00 < 0.2, equipped with non-contact automatic whiteboard calibration technology to ensure measurement accuracy, lithium battery supports 12,000 consecutive tests.
Measurement range of +/- 1000mV, equipped with large LCD display with background light, support manual two-point calibrating and automatic diagnostic function, can verify calibrated status and ElectRode status, fail safe alarm system to improve operational Reliability.
The stainless steel working panel has excellent corrosion resistance, the heating power is 1000W, and the temperature range is RT +~ 300 ℃ to meet various experimental needs.
Temperature control accuracy of +/- 0.1 ℃, using fuzzy PID control technology, with over-temperature alarm and temperature self-tuning function, heating material is high purity graphite, panel size 600 * 400mm.
It has a multi-function smart button design, supports more than 30 Color indicators and 28 kinds of observation Illuminants, adopts non-contact automatic whiteboard calibration technology, Inter-instrument Agreement Delta E * 00 is less than 0.2, high measurement Stability, portable and lightweight only 88 grams.
The special forming process heater has no warpage deformation at high temperature, excellent corrosion resistance of the spray panel, uniform working surface temperature, Heating power 2 × 1000KW, rapid and safe heating.