Frequency range 20KHz to 100KHz, Sensitivity indicated by LED and sound, weight of only 140 grams for portable, suitable for a variety of gas and air leak detection scenarios.
Using 40KHz Frequency and 640KHz crystal time base circuit, the weight is only 50 grams and easy to carry, which can accurately detect air leakage sources in various environments.
The equipment has a 15-liter large-capacity water Tank and an 8mm inner diaMeter water pipe, supports 0 to 99 hours of time control, adopts stainless steel structure and automatic control device, and is suitable for coating stain resistance testing.
The stainless steel pendulum pipe is used to achieve +/- 180 degree swing, equipped with 25 water spray holes and 1-4 rpm adjustable turntable, supporting 50-100kpa water pressure adjustment, and the test water can be recycled without additional waterproof treatment.
Impact accuracy is ensured by double-tube guide structure, the maximum impact energy can reach 320J, the impact height error is controlled within +/- 2mm, and the automatic hammer lifting function is equipped to prevent secondary impact.
Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.
Using single chip control technology, the impact height can be preset and automatically positioned, the accuracy is up to +/- 1mm, and the secondary impact can be automatically prevented. The mass range of the hammer body is 0.25-15 kg, and the two test methods of passing method and layer method are supported.
Instantaneous Response Time Less than 6 seconds warm-up, can detect 3 g/year Sensitivity halogen refrigerant, 405 g lightweight design with 5 hours continuous Working time, with automatic warm-up and two-color LED charge indication function.
It can detect halogen gas leaks of less than 0.5 ounces per year, with an instantaneous Response Time and a Warm-Up Time of less than 90 seconds. It features automatic warm-up and battery protection, and a portable design weighing only 480 grams.
Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.
Speed range 300 to 1000rpm, equipped with chilled down water pipe and grinding disc flushing function, leak-proof spindle design to improve bearing life, suitable for wet grinding and a variety of sample processing.
Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.
Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.
Using platinum sheet material, Conductivity Detector cell constant is 1, Measurement range covers 2.0~ 200 µS/cm, suitable for conventional water detection, interface is three-core socket, no temperature compensation function.
The minimum measurable inner diaMeter is 10mm, the maximum sample thickness is 6mm, and the imported special steel crimp and high-strength pointer components are used. It has good Stability and portability and supports Hardness value conversion.