Programmable High Temperature Chamber

The programmable high-temperature chamber heats through electric heating elements and, in conjunction with temperature sensors and controllers, enables automatic operation according to preset temperature curves. It is used for material heat resistance testing, heat treatment process simulation, and simulating high-temperature environments in scenarios such as electronic component aging and paint curing.
Selection
Determine the inner chamber volume based on the test material dimensions, select the heating capacity according to the experimental temperature range, and choose the heating rate and program steps in combination with process requirements. Pay attention to temperature uniformity indicators, consider the corrosion resistance of the chamber material, and verify the power interface and safety protection function configurations.

Terms

Standards

Instruments

Adopt multi-stage programmable PID controller and TMHM equilibrate Conditioning method, temperature control fluctuation high temperature +/- 0.5 ℃, humidity control deviation +/- 3% RH, with independent temperature limit alarm and 100 group program storage function.

$ 5799.00

Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.

$ 7871.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, support multi-stage programmable control and independent temperature limit alarm system to ensure safe and stable operation of the experiment.

$ 3335.00

Temperature range -60~ 130 ℃, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control and independent temperature limit alarm system, support data export and remote monitoring functions.

$ 10829.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with 120 groups of programmable control and independent temperature limit alarm system to ensure safe and accurate testing.

$ 3235.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with multi-stage programmable control and independent temperature limit alarm system, support Interface to realize remote monitoring.

$ 8461.00

Temperature range -20~ 130 ℃, Temperature Uniformity +/- 2 ℃, equipped with fluorine-free environmental protection refrigeration system, supports multi-stage programmable control, with independent temperature limit alarm and a variety of Safety protection functions.

$ 11025.00

Adopt multi-stage programmable PID controller and TMHM equilibrate Conditioning method, temperature control accuracy +/- 1.0 ℃, humidity control deviation +/- 3% RH, equipped with independent temperature limit alarm system, support 100 sets of programs 1000 cycle steps to ensure the stability and safety of the test process.

$ 10533.00

Using multi-stage programmable PID controller and equilibrate Conditioning method, temperature control fluctuation high temperature +/- 0.5 ℃, humidity control deviation +/- 3% RH, with independent temperature limit alarm and a variety of protection functions.

$ 3630.00

Temperature range -40~ 100 ℃, Temperature resolution 0.1 ℃, using multi-stage programmable PID controller and TMHM equilibrating Conditioning method, equipped with independent temperature limit alarm system and 100 group program capacity to ensure accurate and safe operation.

$ 7377.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with 120 groups of programmable control and a variety of Safety protection functions, support data export and remote monitoring.

$ 4024.00

Adopt multi-stage programmable PID controller to achieve accurate temperature and Humidity control, with small fluctuations; unique air duct circulation system to ensure uniform temperature and Humidity; with 100 sets of programs and 1000 segments capacity, support RS-232 or RS-485 communication interface, easy data monitoring and remote operation.

$ 9152.00

Temperature range RT + 20~ 250 ℃, Fluctuation +/- 0.5 ℃, equipped with low speed swirl/spin turntable to ensure test uniformity, support multi-stage programmable control and ventilation regulation, easy data recording and fault diagnosis.

$ 2447.00

Temperature range -40~ 150 ℃ and Humidity control 30~ 95% R. H, using programmable multi-stage control and independent temperature limit alarm system, equipped with test holes and can be pulled out of the water Tank for easy operation.

$ 9843.00

Unique air duct circulation system is used to ensure that the wind is uniform and does not hurt the seedlings, supports 30-stage temperature and Humidity light programmable control, temperature fluctuation +/- 0.5 ℃, can simulate day and night temperature changes and multi-directional Illuminant environment.

$ 1655.00

Articles

Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
The impact of temperature, humidity, and vibration coupling in a three-environmental test chamber on the structural fatigue of products.
This article explores the impact of the coupled effects of temperature, humidity, and vibration in a three-comprehensive test chamber on the structural fatigue of products. It explains how such a coupled environment accelerates the degradation of material performance, such as high temperature and humidity reducing the material's fatigue limit, while vibration promotes crack propagation.
Temperature gradient control in high-temperature ovens during thermal resistance testing.
The heat resistance test simulates the performance of materials under high temperatures using a high-temperature oven, and the accuracy of its results is highly dependent on the uniformity of temperature inside the oven. If the temperature gradient is poorly controlled, it can lead to uneven heating of samples from the same batch, compromising the validity of the test.
Application of Constant Temperature and Humidity Chambers in the Electronics Industry
A constant temperature and humidity chamber is a device capable of precisely controlling temperature and humidity, used to simulate various environmental conditions that electronic products may encounter. In the electronics industry, it is primarily employed to test the reliability of components, finished products, and processes, such as evaluating material aging or performance changes through high-temperature and high-humidity tests.