Two-channel split design supports multi-point centralized control, with 4-20mA signal input and two-level alarm settings, microprocessor to ensure accurate monitoring, relay output can drive external equipment linkage, Operating temperature range -10~ 50 ℃.
Support 4-20mA signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching and sound and light alarm functions, operating temperature 0-40 ℃, suitable for a variety of Gas detection scenarios.
ABS + PC shell is sturdy and durable, equipped with 2.0 inch 320 * 240 resolution display screen, supports methane, O2, H2S, CO four Gas detection, Response Time is the fastest 20 seconds, battery life is 8 hours, with sound and light vibration triple Alarm mode.
Support 8 channels of 4-20mA signal input, can store 20,000 alarm records, with two-level alarm settings and relay output, suitable for multi-point centralized control to prevent explosions and fire accidents.
Supports 4-20mA signal input, compatible with two-wire and three-wire devices, provides 6 passive switches and RS485 interfaces, with two-level alarm settings, operating temperature 0-40 ℃, suitable for gas safety detection.
Semiconductor Sensor to detect halogen gas leaks of less than 0.5 oz/year, Response Time ≤ 1 second, Sensitivity adjustable, Portable design weighing 250g, up to 9 hours of operation.
Support 16 4-20mA signal input, 4.3 inch color screen display, can store 20000 alarm records, with two-level alarm and four sets of relay output, suitable for multi-point centralized control of Gas detection.
Support 4-20mA/RS485 signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching quantities, two-level alarm can be freely set, suitable for gas safety detection.
Support 4-20mA signal input and RS485 upload, with 2-level alarm and 2 relay output, compatible with two-wire and three-wire equipment, fast response speed and high measurement accuracy, suitable for a variety of Gas detection scenarios.
Detect NH3 gas, range 0~ 100ppm, resolution 0.1ppm, Response Time T90 ≤ 120s, support sound and light alarm, Operating temperature -10~ 50 ℃, Working time for more than 60 hours, Portable design weighs only 170 grams.
Using Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, shell explosion-proof structure, 4-20mA standard signal output, can detect a variety of gas concentrations and have sound and light alarm function.
Explosion-proof structure design, Response Time is less than 30 seconds, with 4-20mA standard signal output, can detect a variety of gas concentrations and set high and low alarm points to ensure industrial environment safety monitoring.
Using Semiconductor Sensor, Response Time T90 is less than 10 seconds, detecting a variety of combustible gases, range 0~ 50% LEL, with sound and light alarm and LED large screen display.
Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, with explosion-proof structure, support 4-20mA and RS485 output, suitable for a variety of Gas detection.
Using 8-bit micro control technology, Response Time is less than 60 seconds, equipped with 12864 point array LCD display gas concentration, with sound, light and vibration triple Alarm mode, Protection Rating up to IP65.