Aluminum Phosphide (AIP) Fumigant Detector

The aluminum phosphide gas detector generates electrical signals through the reaction of its sensor with the gas, measuring the concentration of aluminum phosphide in the environment. It is used to monitor leaks during fumigation for pest control, ensuring operational safety. In grain storage and cargo quarantine, it helps prevent personnel poisoning.
Selection
Ensure the detection range covers 0-1000 ppm when selecting, with an electrochemical sensor lifespan of approximately two years. It should feature audible and visual alarms, data logging capabilities, and explosion-proof certification suitable for warehouse environments. Compare probe response times and calibration cycles, and consider whether portable or fixed installation is required.

Terms

Standards

Instruments

Operating temperature up to 1700 ℃, Furnace volume 80L, aluminum oxide fiber Furnace and double chill down system, support inert and reducing atmosphere environment material sintering treatment.

$ 7867.00

Maximum temperature up to 1700 ℃, Furnace volume 36L, using aluminum oxide fiber material and silicon molybdenum Rod heating element, equipped with a chill down system to ensure sealing performance, support inert or reducing gas environment sintering.

$ 6851.00

The highest temperature is 1400 ℃, the Furnace volume is 4.5L, and the aluminum oxide fiber Furnace and silicon carbon Rod heating elements are used to support the inert gas environment and ensure the uniform and stable sintering of the material.

$ 3720.00

The device uses 1200-1500lx Illumrination degree, achieves 80x magnification and 0.01mm resolution through scale Microscope, and can measure the maximum aperture of 2mm, suitable for aluminum foil pinholing light transmission observation.

$ 554.00

Measurement range 0.000~ 0.3mg/L, can be 100 measurements, supporting special instruments to achieve fast and accurate water quality aluminum ion detection, including a variety of Reagent solutions.

$ 164.00

The activated aluminum oxide ball is used as the adsorption medium, which can adsorption water vapor and chemical corrosion harmful gases, and the oil blocking rate is more than 99%.

$ 146.00

Linear dispersion surface is processed by cold extrusion technology, no risk of wire loosening, support 2um ultra-thin film Spreader, smooth and easy to clean surface, suitable for 250mm length.

$ 101.00

Enclosed aluminum silicate Furnace and nickel-chromium-aluminum alloy heating wire are used to reduce volatile gas corrosion; three-sided heating method combined with PID control, Temperature Fluctuation +/- 5%, accurate and stable temperature control.

$ 1138.00

It can measure the minimum inner diaMeter of 6mm aluminum tube and 8mm thickness profile, Indication Error 0.5HW, using high strength pointer and special steel pressure needle, support Hardness value multi-standard conversion.

$ 1219.00

Operating temperature up to 1400 ℃, Furnace volume 80L, using aluminum oxide fiber Furnace and silicon carbon Rod heating, with double chill down system and accurate Gas flow rate control, support inert atmosphere sintering process.

$ 6012.00

Equipped with high light transmitance Glass liner, transmission Illumrination degree 1000Lux, reading Microscope magnification 100X, can accurately measure pinholing size and quantity.

$ 677.00

Operating temperature of 1400 ℃, Furnace volume of 36 liters, aluminum oxide fiber Furnace and double chill down system, support material sintering process in inert gas environment.

$ 4914.00

Using titanium anodic oxidation aluminum material, the filter is stainless steel, the diaMeter of the flow hole is 4.1mm, the viscosity range is 70-370cSt, the Cup mouth is designed with an anti-spill groove, and each Cup is engraved with a unique serial number.

$ 497.00

Three-sided heating method with aluminum silicate Furnace, high thermal efficiency and uniform temperature. PID control combined with K-type Thermocouple, temperature control accuracy +/- 5%, support 0~ 9999 minutes timing and phased heating.

$ 606.00

Made of titanium anodic oxidation aluminum, the diaMeter of the flow hole is 2.5mm, and each Cup is engraved with an independent serial number, which is suitable for accurate measurement of liquid viscosity in the laboratory.

$ 438.00

Articles