Paper Glue Coating Machine

Instruments

Using 470nm wavelength and double-sided LED Illuminant irradiation, equipped with amber filter and 105 * 163mm glue cutting area, accurate fluorescence sample separation operation can be achieved.

$ 201.00

Film Film thickness 22.9μm, Spreader width 30cm, wear-resistant stainless steel material, molding process, suitable for low viscosity glue and thermal glue experimental Spreader.

$ 186.00

The formed pRoduction process ensures that the film is uniform, the film thickness is 22.9μm, the application width is 300mm, which is suitable for low viscosity glue experiment, and the material is wear-resistant stainless steel to prolong the service life.

$ 167.00

Using double-sided LED Illuminant and 400nm wavelength, equipped with amber filter, the glue cutting area is up to 105 * 163mm, which is convenient for accurate separation of fluorescently labeled nucleic acid protein samples.

$ 212.00

Using 365nm wavelength double-sided LED Illuminant, equipped with amber filter, the glue cutting area is up to 105 * 163mm, which can clearly observe the fluorescence and accurately separate the target area.

$ 223.00

Vacuum principle measurement paper breathability performance, Measurement range 0-1000ml/min, test area of 10cm ², suitable for a variety of industrial paper mass detection.

$ 1134.00

Adopting dip coating with double roll extrusion structure, Spreader thickness 0.3-10 mm adjustable, mechanical speed 1.2m/min can be slowly adjusted, built-in glue circulation system to ensure Spreader uniformity.

$ 29120.00

K-shaped cogging bottom design, large tooth spacing, suitable for high viscosity Coating, wet film thickness 300μm, leveling well, suitable for large glue viscosity application scenarios.

$ 120.00

K-shaped cogging design, large tooth spacing, suitable for high viscosity Coating, wet film thickness 100 μ m, leveling, wider cogging bottom, suitable for glue and other viscous materials Spreader.

$ 120.00

K-shaped cogging design, large tooth spacing, suitable for high viscosity Coating, wet film thickness 250μm, leveling well, the bottom of the cogging is wider, suitable for applications with large glue viscosity.

$ 120.00

K shape cogging design, large tooth spacing, suitable for high viscosity Coating, excellent leveling, wet film thickness 80μm, application width 300mm, suitable for the application of high viscosity of glue.

$ 178.00

K-shaped cogging design, large tooth spacing, suitable for high viscosity Coating, wet film thickness of 150 μ m, leveling well, the bottom of the cogging is wider, suitable for large glue viscosity application scenarios.

$ 178.00

Adopting double column diagonal support structure is convenient for disassembly and washing, equipped with five layers of filtrate net to effectively filtrate impurities, equipped with return buffer system to eliminate bubbles, and thermostatic fuel Tank to keep Flow rate stable.

$ 40415.00

K-shaped cogging bottom design, large tooth spacing, suitable for high viscosity Coating, wet film thickness 80 μ m, leveling, suitable for large glue viscosity application scenarios.

$ 120.00

K-shaped cogging, large tooth spacing, suitable for high viscosity Coating, leveling, wet film thickness of 80 μ m, the bottom of the cogging is wider, suitable for applications with high glue viscosity.

$ 157.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
Process optimization of heating coater in lithium battery electrode preparation
This article introduces process optimization methods for heating coaters in the preparation of lithium battery electrodes.
The Stripe Issue Caused by Tension Fluctuations in Roll-to-Roll Laboratory Coaters and Its Solutions
This paper analyzes the causes of and countermeasures for coating streaks resulting from tension fluctuations in roll-to-roll laboratory coaters.
Analysis of Common Defects in Laboratory Coating Machine Blade Coating and Adjustment Methods for Process Parameters
This article introduces common defects in the blade coating process of laboratory coaters, such as streaks, orange peel, bubbles, uneven thickness, and missed coating. It analyzes the causes of these issues, which are primarily related to material properties, operating parameters, and environmental factors.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Using a spray coater to achieve the preparation of functionally graded films.
This paper introduces a method for preparing functionally gradient films using a spray coating machine.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Short Span Compression Strength (SCT) Tester for Analyzing Paper Compression Resistance
The short-span compressive strength (SCT) tester is used to measure the resistance of materials such as paper and cardboard to compression over a short distance, primarily following international standards such as ISO 9895.
IGT Printability Tester Evaluates Paper Surface Pick Resistance
This article introduces how to use the IGT printability tester to evaluate the surface pick resistance of paper. Picking refers to the phenomenon where the tack force of the ink is too high during printing, causing the surface fibers of the paper to be lifted, which affects print quality.
Internal Bond Strength Scott Tester for evaluating interlayer bonding force of paper.
This article introduces the method of evaluating the interlayer bonding strength of paper using a Scott tester. The interlayer bonding strength affects the printing and mechanical properties of paper. During testing, the instrument peels the paper vertically through an adhesive test head, records the energy required for separation, and calculates the internal bond strength.
Tensile strength testing machine measures the tensile properties of paper.
The tensile strength tester is used to determine the tensile properties of paper by simulating the stretching process to obtain key parameters such as tensile strength and elongation at break. The testing follows standards such as ISO and GB to ensure reliable results.