Optical Transmittance Tester

An optical transmittance tester measures the transmittance of a sample by irradiating it with a light source and detecting the ratio of transmitted light intensity to incident light intensity. It is used to evaluate the optical properties of transparent or translucent materials, such as plastics and glass, in quality control and research and development.

Instruments

The three-in-one optical path design can simultaneously measure the transmittance of blue light at 430nm, purple light at 395nm and visible light, and the test aperture Φ 1mm is suitable for large thickness materials. Real-time dynamic self-Adjustment ensures accurate data.

$ 373.00

The three-in-one optical path measures the transmittance of three wavelengths at one time, the test aperture is 1mm to adapt to small-sized materials, and the parallel light design ensures stable measurement of thick materials, with an accuracy of +/- 2% and a resolution of 0.1%.

$ 361.00

Using 3-in-1 optical path design, one hole can simultaneously measure three wavelengths transmittance. Equipped with 1mm test aperture and Automatic calibration function, support 850nm/940nm infrared and 550nm visible light measurement, accuracy of +/- 2%.

$ 373.00

Adopt three-in-one parallel light path design, one measurement of visible light, infrared and ultraviolet transmittance; test aperture 1.3mm, suitable for small size and thick materials; Automatic calibration and large capacity storage function.

$ 361.00

It adopts parallel light path design, supports 47mm Film thickness material test, and can simultaneously measure ultraviolet 365nm, infrared 940nm and visible light transmittance. It has real-time self-calibrating function, and the operation is simple and fast to display three results.

$ 341.00

The three Illuminants share a test hole, and the 380nm-760nm visible light, 940nm infrared and 365nm ultraviolet transmittance can be obtained in one measurement. The parallel light design can test large thickness materials, and the 1mm test aperture is suitable for small size samples.

$ 373.00

Repeatability and accuracy are ensured with dual optical path sensing arrays and UV reinforced silicon photodiodes with 0.0001 resolution, 0-200% Transmittance Measurement range and support for APHA/PtCo, Gardner and Saybolt chroma scales.

$ 1687.00

Compact and easy to carry, resolution up to 0.01, Repeatability ≤ 0.02. Adopts dual light path design, supports three Standard light sources and multiple measurement calibers, and data can be stored in the cloud through the mobile phone Mini Program.

$ 719.00

The three-in-one optical path design can simultaneously measure four sets of data, the test aperture of 1.3mm supports small-size material detection, with Automatic calibration and large-capacity storage functions. Measurement accuracy of +/- 2% ensures stable and reliable results.

$ 361.00

Utilizing a 360-780nm composite full-spectrum LED light source, equipped with a 256-pixel CMOS detector and a concave grating, it achieves spectral acquisition at 10nm intervals, supporting micro-transmittance measurements and a variety of optical index tests.

$ 6851.00

Using photoelectric detection and microcomputer servo system, high Sensitivity, minimum reading +/- 0.005 °, Repeatability ≤ 0.007 °, low optical rotation samples with measurable transmittance ≥ 10%, no reading error.

$ 1098.00

Compact and portable, supports three Standard light sources and dual light path design, measurement resolution up to 0.01, Repeatability ≤ 0.02, data cloud storage can be connected through the mobile phone Mini Program.

$ 557.00

Using 360~ 780nm composite full Light spectrum LED Illuminant, equipped with 256 pixel CMOS Detector, measurement wavelength range of 360~ 780nm, interval of 10nm, to achieve haze, transmittance, chroma and other Optical inspection indicators of accurate testing.

$ 6980.00

Optical inspection components imported, measurement range 0.0-99%, accuracy ≤ 2%, with single and continuous two measurement modes, support MAX Maximum, MIN Minimum, average statistics, can store 800 sets of data and connect to computer communication.

$ 344.00

The minimum test aperture is 0.5mm, and the three Illuminants share a test hole. Three transmittance data of 550nm, 850nm and 940nm can be obtained for one hole. Real-time dynamic self-Adjustment, Test accuracy +/- 2%.

$ 538.00

Articles

Application of Laboratory Coating Machines in the Coating of Optical-Grade PET Anti-Reflection Coatings
This article discusses the application of laboratory coating machines in the preparation of anti-reflective coatings on optical-grade PET substrates. By controlling parameters such as coating speed and gap, the coating machine enables precise adjustment of coating thickness, thereby enhancing light transmittance and reducing reflection.
Haze Transmittance Meter for Evaluating Optical Clarity of Contact Lenses
This article introduces how a haze transmittance meter is used to evaluate the optical clarity of visual correction products such as contact lenses. Haze refers to the blurriness caused by light scattering, while transmittance reflects the material's ability to transmit light. Together, these two factors determine clarity.
Haze and transmittance integrated machine measures the quality of functional films.
This article introduces how an integrated haze and transmittance meter measures the quality of functional films. Haze refers to the degree to which a material scatters light, while transmittance reflects its overall ability to transmit light.
Transmittance Tester Measures the Clarity of Optical Films
This article introduces how to use a transmittance tester to measure the clarity of optical films. Clarity refers to the fidelity of imaging after light passes through the film. The tester is based on the principle of light transmission, calculating the clarity value using a formula by measuring the intensity of parallel transmitted light and scattered light.
Haze meter measures light transmission and scattering in agricultural film.
This article introduces how a haze meter measures the light transmittance and the proportion of scattered light in agricultural films. Haze is the percentage of scattered light in the total transmitted light, while light transmittance is the ratio of transmitted light to incident light.
Transmittance Meter Selection Guide: Principles for Matching Light Sources and Samples
This article introduces how to select the light source for a transmittance meter based on sample characteristics. The types of light sources include halogen tungsten lamps, LEDs, and lasers, which are suitable for wide-band, monochromatic, or high-precision measurements, respectively.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
Haze meter for detecting haze and light transmittance of optical-grade resin
This article introduces the basic concepts, measurement principles, and practical applications of haze and light transmittance in optical-grade resin materials.
Haze meter measures the haze and light transmittance of transparent coatings.
This article introduces the method of measuring the haze and light transmittance of transparent coatings using a haze meter. Haze refers to the degree of light scattering after passing through a material, while light transmittance reflects the amount of light directly transmitted.