Metal Magnetic Thickness Probe

The metal magnetic thickness probe is based on the principle of magnetic induction. The probe generates a magnetic field, and when it approaches a non-magnetic coating on a ferromagnetic substrate, the change in the magnetic field is proportional to the coating thickness. It is used to measure the thickness of coatings on iron-based materials, such as paint or plating, ensuring coating uniformity in industrial quality inspections.
Selection
When selecting a metal magnetic thickness measurement probe, consider whether the substrate material is ferromagnetic, the coating type such as non-magnetic or conductive properties, ensure the measurement range matches the coating thickness, the accuracy meets the application requirements, the probe size fits the shape of the workpiece, account for environmental factors like temperature that may affect performance, and refer to standard calibration methods.

Terms

Standards

Instruments

Measurement range of 0~ 1250μm using magnetic Induction principle, with +/- 3% error accuracy and 0.1μm resolution, supports single continuous two Measurement mode, equipped with wear-resistant metal probe to ensure measurement Stability.

$ 320.00

Adopting the principle of magnetic Induction Thickness Measurement range 0~ 1250 microns, suitable for LEEB242 models, can be connected to the printer output data, suitable for nonmagnetic Coating thickness detection on magnetic metal substrates.

$ 219.00

Using magnetic Induction principle, Measurement range of 0-10000 μ m, support one and two point calibrating, split structure design can adapt to a variety of Probe types, to meet different Coating thickness measurement needs.

$ 340.00

Adopt magnetic Induction principle to measure 0-3000μm Film thickness, equipped with wear-resistant Ruby Probe and IP65 Protection Rating, Probe with LED status indicator light, support electronic calibrated certificate.

$ 946.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Adopt magnetic Induction technology for measurement in the range of 0-1500 μm, error +/- 1%, equipped with 90 ° Probe for easy operation in confined spaces, with color Touchscreen and USB interface to display data in real time.

$ 1602.00

Using magnetic Induction principle, automatically identify magnetic metal substrate, high wear-resistant carbide Probe service life of more than 500,000 times, with zero point, single point, five point Adjustment, can store 1600 measurement data and connect to computer software.

$ 311.00

Measurement principle using magnetic method, thickness range 0-3000μm, error +/- 3%, with split Probe structure, support single and continuous Measurement mode, equipped with RS-232C interface.

$ 461.00

Adopt magnetic Induction principle measurement Coating thickness, Measurement range 0-1250μm, resolution up to 0.1μm, with automatic identification Probe, Data storage and upper and lower limit alarm function, aluminum shell is sturdy and durable.

$ 296.00

Magnetic surface temperature measurement Probe through strong magnetic adsorption on the workpiece, small volume and light mass, Sensor and magnet insulation to ensure measurement accuracy, the highest temperature 480 ℃, especially suitable for circular workpiece surface.

$ 666.00

Measurement range 0~ 1250μm, error +/- 3%, minimum measurement surface F7mm, suitable for complex structure right angle measurement scene.

$ 469.00

Detachable built-in Probe design, support one-handed operation, Measurement range 0~ 13mm, accuracy +/- 3%, suitable for Coating thickness detection of different metal substrates.

$ 932.00

Adopting the principle of magnetic thickness measurement, the range can reach 13000 μm, the error range is +/- 3%, with two methods of continuous measurement and single measurement, supporting large-capacity storage and upper and lower limit alarm functions, and the wear-resistant alloy probe is sturdy and durable.

$ 743.00

Measurement range 0~ 1500 microns, error +/- 1%, support magnetic Induction principle, IP65 Protection Rating and 250 reading storage, suitable for ferrous metal substrate nonmagnetic coating environment.

$ 890.00

Adopt magnetic Induction principle measurement, thickness range 0~ 1000μm, error +/- 3%, with low voltage prompt function, support split Probe and customized range, adapt to different curvature matrix measurement needs.

$ 243.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Brinell hardness tester is used for hardness testing of plastics and soft metal coatings.
This article introduces how a Brinell hardness tester is used to measure the hardness of plastics and soft metal coatings.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Controllable Coating of Composite Separator Coatings for Lithium Metal Batteries
This article primarily explores the controllable coating technology for composite separator coatings in lithium metal batteries.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.