The test incubator simulates specific environments through temperature and humidity control, and is used for experiments such as microbial cultivation and seed germination. The chamber is equipped with heating and cooling systems as well as humidity regulation devices to maintain stable preset conditions.
Selection
When selecting, consider a temperature range that covers experimental needs, humidity control accuracy that matches sample characteristics, and chamber volume that accommodates the sample quantity. Pay attention to parameters such as temperature uniformity and fluctuation, as well as materials that are corrosion-resistant and easy to clean.

Terms

Standards

Instruments

Integrated Incubator and Shaker functions, Oscillation Frequency 40~ 300rpm, Temperature range RT + 5~ 65 ℃, 304 stainless steel liner and microcomputer PID control, with UV sterilization and automatic storage setting paraMeters.

$ 1427.00

Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.

$ 2315.00

Integrated Incubator and Shaker functions, small footprint and large bottle capacity; Microcomputer PID control temperature and Oscillation Frequency, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner is easy to clean, supports multi-stage programming and UV sterilization to ensure safe and efficient operation.

$ 1773.00

Mirror stainless steel liner is easy to clean, Temperature range 15~ 45 ℃, Temperature Fluctuation +/- 0.5 ℃, three speed fan to avoid sample volatilization, with independent temperature limit alarm system to ensure safety.

$ 2150.00

Temperature control accuracy of +/- 0.3 ℃, equipped with ultraviolet sterilization system to prevent pollution, support multi-stage programming and independent temperature limit alarm to ensure experimental safety and uniformity, suitable for long-term foster needs.

$ 3107.00

Mirror stainless steel studio easy to clean, Temperature range 0-65 ℃ accuracy +/- 0.5 ℃, equipped with UV sterilization lamp and ultrasonic humidifier, support 1-9999 minutes timing function.

$ 2203.00

Equipped with ultraviolet sterilization system to effectively prevent pollution, temperature control accuracy of +/- 0.3 ℃, support multi-stage programming and independent temperature limit alarm, to ensure the safety and stability of the experiment.

$ 943.00

Unique air duct structure to ensure temperature uniformity +/- 1 ℃, microcomputer intelligent temperature control accuracy of +/- 0.5 ℃, equipped with auxiliary thermostat and leakage protection, liner made of stainless steel for easy cleaning, optional ultraviolet sterilization system.

$ 711.00

The cavity preheating technology implementation of uniform temperature distribution, with the forced convection system to shorten the temperature recovery time. Temperature Uniformity +/- 0.5 ℃, volume 130L, equipped with multiple over-temperature protection and adjustable shelf design.

$ 1216.00

Using fluorine-free refrigeration technology, Temperature range 0~ 60 ℃, Temperature Uniformity +/- 1.5 ℃, equipped with mirror stainless steel liner and microcomputer intelligent temperature control system, support 1-9999 minutes timing function.

$ 877.00

The mirror stainless steel liner is used for easy cleaning, Temperature Fluctuation is only +/- 0.2 ℃, the circulating wind speed is automatically adjusted to avoid sample volatilization, and 7 sets of programs can be preset by supporting multi-stage programming control.

$ 1053.00

Microcomputer intelligent temperature controller, Temperature Fluctuation +/- 0.5 ℃, Temperature Uniformity +/- 1 ℃, duct structure to ensure uniform temperature, liner arc design for easy cleaning, optional ultraviolet sterilization and remote control interface.

$ 554.00

Adopting a fluorine-free refrigeration design, the cooling time is reduced by more than 40% compared to traditional equipment, and the temperature fluctuation is controlled within +/- 0.5 ° C. It is equipped with an ultraviolet sterilization system to effectively prevent pollution and support remote monitoring.

$ 880.00

The mirror stainless steel liner is easy to clean, Temperature range 0~ 60 ℃ and fluctuation +/- 0.5 ℃, three wind speed adjustment to avoid sample volatilization, with independent temperature limit alarm system to ensure safe operation of the experiment.

$ 990.00

Unique air duct structure to ensure temperature uniformity +/- 1 ℃, microcomputer intelligent temperature control accuracy of +/- 0.5 ℃, equipped with auxiliary thermostat and leakage protection device, liner made of stainless steel for easy cleaning.

$ 882.00

Articles

Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Application of Drop Hammer Impact Testing Machine in Evaluating Impact Resistance of Composite Materials
This article introduces how the drop-weight impact testing machine evaluates the impact resistance of composite materials. The test releases a weight to strike the specimen, measuring parameters such as energy absorption, peak load, and damage area, simulating low-velocity impacts like tool drops.
Impact of the Fixture Design of a Drop Hammer Impact Tester on the Plastic Impact Strength Results
This article primarily discusses the impact of the fixture design of a drop-weight impact testing machine on the results of plastic impact strength tests. The geometric parameters of the fixture, clamping method, and contact surface material can alter the stress state and energy transfer of the specimen, thereby affecting the accuracy of the test data.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Application of Tensile Testing Machine in 180-Degree Peel Strength Test for Packaging Tape
This article introduces how a tensile testing machine is used to test the 180-degree peel strength of packaging tape.
Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.