High and Low Temperature Humidity Thermal Cycling Test Chamber

This device achieves temperature variations from -70℃ to 150℃ through a compressor and electric heating tubes, combined with a humidification system to maintain humidity levels between 20% and 98%. It simulates the resistance of materials under alternating temperature and humidity conditions. It is used to test the adhesion of coatings, plastic embrittlement, paper deformation, and other factors, commonly employed during product quality verification stages.
Selection
When selecting, pay attention to the matching of the workspace size with the sample specifications, determine the temperature range based on the actual regional climate of use, and set the humidity control precision according to the testing standard requirements. The brand of the compressor affects low-temperature stability, and stainless steel inner liners offer better corrosion resistance. It is also necessary to verify the compatibility of the equipment's power supply with the site conditions.

Terms

Standards

Instruments

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.

$ 12579.00

Temperature range -20~ 150 ℃, humidity control 30~ 98% R.H., stainless steel liner and ultra-fine Glass insulation cotton, equipped with independent over-temperature protection and multi-layer conductive film observation window to ensure stable and reliable testing.

$ 7771.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H, with multi-wing air supply cycle to ensure uniform distribution, improve test reliability.

$ 11079.00

Temperature range -40~ 150 ℃, humidity control 30~ 98% R. H, Temperature Uniformity ≤ +/- 2 ℃, using PID control solid state relay and steam boiler humidification to ensure stable and reliable operation.

$ 12579.00

Temperature range -70~ 150 ℃, humidity uniformity +/- 2% -3% R.H., multi-layer conductive film observation window anti-frost design, equipped with independent over-temperature protector to ensure safe operation of the equipment.

$ 9384.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

Studio volume 100L, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, stainless steel liner and ultra-fine Glass cotton insulation, equipped with independent over-temperature protection and multi-layer conductive film observation window.

$ 7771.00

Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., equipped with multi-wing air supply circulation system to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.

$ 11482.00

Temperature range -30~ 150 ℃, Humidity Control Range 30~ 98% R.H., using PID control solid state relay and steam boiler humidification, equipped with multi-layer conductive film observation window and multiple safety protection systems.

$ 11627.00

With -60~ 150 ℃ wide temperature control and 30~ 98% RH humidity range, using French Taikang Compressor and multi-wing air supply circulation to ensure uniform distribution of temperature and humidity and improve test reliability.

$ 10401.00

With -40~ 150 ℃ wide temperature control and 30~ 98% humidity range, using French Taikang Compressor and multi-wing air supply circulation, high temperature and humidity uniformity, support 100 groups of program editing, improve test efficiency.

$ 14112.00

Using French Taikang fully enclosed Compressor, equipped with multi-wing air supply circulation system to ensure uniform distribution of temperature and humidity, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2-3% R.H, improve test accuracy and efficiency.

$ 7754.00

Adopt stainless steel liner and ultra-fine Glass cotton insulation structure, equipped with multi-layer conductive film observation window and silicone rubber sealing. Temperature control accuracy +/- 0.5 ℃, humidity fluctuation +/- 2% RH, with PID control and safety protection system.

$ 8739.00

Adopt stainless steel liner and ultra-fine Glass cotton insulation, equipped with multi-layer conductive film observation window and frost protection device. Temperature control accuracy +/- 0.5 ℃, humidity fluctuation +/- 2% RH, with PID control and multiple safety protection to ensure stable and reliable testing.

$ 8900.00

Articles

Application of Drop Hammer Impact Testing Machine in Evaluating Impact Resistance of Composite Materials
This article introduces how the drop-weight impact testing machine evaluates the impact resistance of composite materials. The test releases a weight to strike the specimen, measuring parameters such as energy absorption, peak load, and damage area, simulating low-velocity impacts like tool drops.
Impact of the Fixture Design of a Drop Hammer Impact Tester on the Plastic Impact Strength Results
This article primarily discusses the impact of the fixture design of a drop-weight impact testing machine on the results of plastic impact strength tests. The geometric parameters of the fixture, clamping method, and contact surface material can alter the stress state and energy transfer of the specimen, thereby affecting the accuracy of the test data.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Shore Durometer Selection: Matching Principles of Hardness Models and Measurement Ranges
This article introduces the selection method for Shore durometers, with the core focus on ensuring that the hardness type matches the material's hardness range and rebound characteristics. When selecting, the principle that the measured value falls within 20% to 80% of the full scale should be followed to avoid data distortion.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Selection of abrasion testing machine is based on the wear form, choosing between linear or rotational types.
When selecting a wear testing machine, the first step is to determine based on the primary wear forms the material actually encounters.
Friction and wear testing machine evaluates the wear resistance of self-lubricating polymer materials.
This article introduces how to use a friction and wear testing machine to evaluate the wear resistance of self-lubricating polymer materials. It explains the working principles of the testing machine, including the basic formulas for measuring the friction coefficient and wear rate.
Melt flow index instrument controls the flowability and stability of polypropylene injection molding process.
This article explores how to assess and regulate the stability of polypropylene's flowability in injection molding processes by measuring its melt flow rate. It explains the principles behind characterizing flowability and analyzes the impact of factors such as material batch variations and process parameters on stability.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Differential Scanning Calorimetry measures the phase transition temperature of liquid crystal polymers.
This article introduces the method of determining the phase transition temperature of liquid crystal polymers using a differential scanning calorimeter. The differential scanning calorimeter analyzes the phase transition behavior of materials by comparing the heat difference between the sample and a reference material, recording the heat flow curve during temperature changes.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.