Thermal Humidity Cycle Test Chamber

The constant temperature and humidity alternating test chamber precisely controls temperature and humidity within a sealed space and enables programmed alternating changes through its refrigeration, heating, humidification, and dehumidification systems. It is used to simulate the tolerance of products under different climatic conditions and is commonly applied in environmental adaptability verification for electronic components and coating samples.
Selection
When selecting, consider that the temperature and humidity range must cover the testing standards, with fluctuations controlled within ±0.5℃/±2% RH. Reserve one-third of the chamber volume based on sample dimensions, and ensure it has program editing and historical data export functions. The stainless steel inner chamber should be corrosion-resistant, and the compressor must meet the requirements for continuous alternating cycle operation.

Terms

Instruments

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H, with multi-wing air supply cycle to ensure uniform distribution, improve test reliability.

$ 11079.00

Adopt mirror stainless steel liner and PID Control mode, Temperature range 0~ 60 ℃, Humidity deviation +/- 5~ 8% R.H., 99 cycle programs and independent temperature limit alarm system.

$ 1414.00

Multi-wing air supply cycle to ensure uniform distribution of temperature and humidity, support 120 sets of program control and data export functions, Temperature Fluctuation +/- 0.5 ℃, humidity deviation +/- 2% R.H., with complete fault diagnosis and safety protection mechanism.

$ 5931.00

With -60~ 150 ℃ wide temperature range and 30~ 98% RH humidity control, multi-wing air supply cycle to ensure uniform temperature and humidity, 7.0 inch large screen programmable controller supports 100 sets of programs to improve test efficiency and accuracy.

$ 8142.00

With 1000 segment program capacity and 999 step cycle, temperature control accuracy +/- 1 ℃ humidity control accuracy +/- 2% RH, using cascade refrigeration system and steam humidification method, support reservation start and fault self-diagnosis function.

$ 5043.00

Temperature range -5~ 80 ℃, Humidity deviation +/- 3% RH, mirror stainless steel liner and JAKEL circulating fan to ensure Temperature uniformity, support 99 cycle complex experimental procedures.

$ 4663.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Inner Chamber dimensions 800 * 1000 * 1000mm, temperature range -20~ 150 ℃, humidity range 30~ 98% R.H., using French Taikang Compressor and multi-wing air supply circulation, uniform temperature and humidity distribution, high control accuracy.

$ 9191.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

Multi-wing air supply cycle is used to ensure uniform temperature and humidity, support 120 sets of program control and data export functions, Temperature Fluctuation +/- 0.5 ℃, to meet a variety of industrial standard testing requirements.

$ 3995.00

Using French Taikang fully enclosed Compressor, temperature range -40~ 150 ℃, humidity range 30~ 98% RH, with 100 sets of programs 1000 cycle capacity, 7.0 inch large screen programmable controller.

$ 10401.00

Adopt fluorine-free environmental protection design, Humidity Control Range 35-95% RH, input Power 2300W, with PID automatic calculation function, ensure accurate and stable thermal insulation Humidity control, equipped with multiple Safety protection systems.

$ 5405.00

With 1000 segment program capacity and 999 step cycle, temperature control accuracy +/- 1 ℃, humidity control accuracy +/- 2% R.H., equipped with automatic calculation and fault diagnosis functions, support RS-232 communication interface to achieve remote monitoring.

$ 5011.00

Adopt multi-stage programmable PID controller and TMHM equilibrate Conditioning method, temperature control accuracy +/- 1.0 ℃, humidity control deviation +/- 3% RH, equipped with independent temperature limit alarm system, support 100 sets of programs 1000 cycle steps to ensure the stability and safety of the test process.

$ 10533.00

With 1000 segments program control, each segment can cycle 999 steps, Temperature range 25~ 100 ℃, humidity control range 20~ 98% R.H., support automatic calculation and fault self-diagnosis function.

$ 5173.00

Articles

Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Constant Temperature and Humidity Chamber Testing for Environmental Adaptability of Hot Melt Adhesive
This article introduces the method of testing the environmental adaptability of hot melt adhesive using a constant temperature and humidity chamber. The performance of hot melt adhesive is easily affected by temperature and humidity, and the purpose of the test is to evaluate its stability under different climatic conditions.
Constant Temperature and Humidity Chamber Testing for Ink Environmental Adaptability
This article introduces the method of testing the environmental adaptability of ink using a constant temperature and humidity chamber. Ink is prone to issues such as adhesion, discoloration, or reduced adhesion when exposed to changes in temperature and humidity.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.
The difference between thermal shock test chambers and constant temperature and humidity chambers
This article compares the differences between thermal shock test chambers and constant temperature and humidity chambers in terms of working principles, key performance, and applications.
Application of Constant Temperature and Humidity Chambers in the Electronics Industry
A constant temperature and humidity chamber is a device capable of precisely controlling temperature and humidity, used to simulate various environmental conditions that electronic products may encounter. In the electronics industry, it is primarily employed to test the reliability of components, finished products, and processes, such as evaluating material aging or performance changes through high-temperature and high-humidity tests.
Common Operational Fault Analysis and Daily Maintenance Strategies for Constant Temperature and Humidity Test Chambers
This paper focuses on typical issues faced by constant temperature and humidity test chambers in practical applications, such as temperature deviations, abnormal humidity control, and blockages in the water circuit system. It delves into the underlying causes of these faults and proposes a maintenance framework centered on daily inspections and standardized operations.
Comparison of Humidity Control Methods in Constant Temperature and Humidity Test Chambers: Wet and Dry Bulb Method vs. Electronic Sensor Method
This article will explain the principles, advantages, and disadvantages of these two methods to help you make a more informed decision when selecting equipment.
Technical Selection and Application of Constant Temperature and Humidity Chambers
This article primarily discusses how to select and use a constant temperature and humidity chamber. It is mainly used to test the performance of materials and products under varying temperature and humidity conditions.