With split Probe design, Temperature Measurement range covering -10~ 50 ℃, can be extended to 1000 ℃, Humidity Measurement range 5~ 98% RH, error +/- 1.5 ℃ and +/- 5%, support unit conversion, portable and durable.
Simultaneous measurement environment Humidity and surface temperature, accuracy of +/- 0.5 ℃, storage of 20000 readings, support for a variety of K-type Probe extended measurement, with real-time graphics display and wireless transmission function.
Using split Sensor design, Temperature Measurement range -10~ 50 ℃, Humidity Measurement range 5~ 98% RH, support ℃/F unit conversion, equipped with 9V battery power supply.
Adopt equilibrating Conditioning Control system, Temperature range -60 ℃~ + 150 ℃, Humidity range 20~ 98% R.H., with energy saving function and comprehensive protection system to ensure long-term accurate and stable operation.
Humidity controller with dry and wet bulb type or electric kiln type, temperature fluctuation +/- 0.5 ℃, humidity deviation +/- 3% RH; with independent temperature limit alarm, Compressor multiple protection and water shortage protection functions to ensure safe operation.
The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.
Adopt equilibrating Conditioning Control system, Temperature range -20~ 150 ℃, humidity control 20~ 98% R.H., with multi-stage heating pipe and circular split humidifier, with energy-saving regulating valve to achieve segmented control, ensure uniform and stable heat preservation Humidity.
Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.
Using split Sensor design, the temperature range covers -50~ 70 ℃, Humidity Measurement range 20%~ 99% RH, supports ℃/F unit conversion, which is convenient for indoor and outdoor environment monitoring.
Using split Sensor design, Temperature Measurement range -10~ 50 ℃, Humidity Measurement range 5~ 98% RH, support ℃/F unit conversion, resolution up to 0.1 ℃ and 1% RH.
Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.
Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H, with multi-wing air supply cycle to ensure uniform distribution, improve test reliability.
Microcomputer temperature and humidity controller, Temperature Fluctuation +/- 0.5 ℃, humidity fluctuation +/- 5% RH, with over-temperature protection, independent temperature limit alarm system to ensure safe and stable operation of the experiment.
Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.
With -60~ 150 ℃ wide temperature control and 30~ 98% RH humidity range, using French Taikang Compressor and multi-wing air supply circulation to ensure uniform distribution of temperature and humidity and improve test reliability.