Heating Thermostat

A heating thermostat maintains a stable set temperature by heating through electrical heating elements and using temperature sensor feedback control. It is used for sample heating, reaction insulation, or material testing and is commonly found in equipment such as ovens and water baths.
Selection
Select the model based on the experimental temperature range and accuracy requirements, ensure the sample capacity matches the heating chamber size, pay attention to heating speed and temperature uniformity, check safety protection features such as over-temperature power cutoff, and ensure compatibility with existing power specifications.

Terms

Standards

Instruments

Range 20~ 2000000 mPa · s, repRoducibility +/- 0.5% F. S, support 0.3~ 60rpm multi-speed switching, equipped with Thermostat to achieve temperature stability +/- 0.05~ 0.1K, can display viscosity, speed and torque paraMeters simultaneously.

$ 1235.00

Temperature range + 5~ 95 ℃, pump flow 15L, providing High Accuracy and uniform temperature constant field source, suitable for a variety of laboratory environments.

$ 627.00

Temperature range RT + 5~ 150 ℃, high temperature uniformity, providing 15L large flow cycle, Tank size is 300 * 235 * 200mm, suitable for a variety of experimental needs.

$ 767.00

Temperature range + 5 to 200 ° C, pump flow up to 15L, provides High Accuracy, uniform temperature and controlled constant field source for a variety of experimental environments.

$ 909.00

Automatic dual-drive heating cabin door avoids human interference, 230 ° C limit heating temperature meets most samples, 0.001g High Accuracy weighing and 35cm heating cabin height improve test efficiency.

$ 2333.00

Temperature range -5~ 95 ℃, using Air-Cooled fully enclosed Compressor and overall foaming process, high cooling efficiency, low noise and good thermal insulation performance.

$ 1155.00

Temperature range -30~ 100 ℃, Temperature Fluctuation +/- 0.1 ℃, equipped with powerful pressure suction pump, intelligent microcomputer control, over-temperature and low temperature sound and light alarm and liquid level protection function.

$ 2042.00

Using digital microcomputer thermostat accuracy of 0.1 ℃, equipped with hot air circulation system to make Temperature Uniformity +/- 2.0 ℃, with timing and temperature control protection function, mirror stainless steel liner durable and easy to clean.

$ 649.00

Using Air-Cooled fully enclosed Compressor and overall foaming process, high cooling efficiency and good insulation performance, Temperature range -20~ 95 ℃, Tank size is 300 * 150 * 150mm.

$ 1106.00

Temperature range -10~ 95 ℃, using Air-Cooled fully enclosed Compressor, high cooling efficiency, low noise, the inner Tank is made of stainless steel, and the overall foaming and heat insulation performance of the low temperature Tank is good.

$ 1845.00

Temperature range -20~ 95 ℃, using Air-Cooled fully enclosed Compressor refrigeration, cooling fast low noise, the overall foaming performance of the Tank body is good, the inner Tank is made of stainless steel.

$ 2934.00

Using infrared heating technology, the heating speed reaches 5 ℃/sec, Temperature uniformity 1-3 ℃, supports internal and external temperature sensor switching, equipped with 6 independent stations, Max. stirring Capacity 18L, DC motor runs smoothly.

$ 1663.00

Temperature range -40~ 95 ℃, using Air-Cooled fully enclosed Compressor and overall foaming process, good cooling effect, excellent thermal insulation performance, the inner Tank is made of stainless steel.

$ 2631.00

The thermostat is used to control the heat transfer of the heating tube, the temperature accuracy is +/- 2 ℃, and the heating range is adjustable from room temperature to 250 ℃; it is equipped with light curtain protection device and temperature abnormal alarm function, and the operation is safe and reliable; the parallelism of the upper and lower templates is within 0.05 to ensure uniform pressure.

$ 5237.00

Temperature range -20~ 100 ℃ and accuracy of +/- 0.1 ℃, equipped with a strong pressure suction pump and external Bath connection port, support over-temperature low temperature sound and light alarm and liquid level protection functions to ensure the safety and reliability of the sample.

$ 1400.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Selection Recommendations for Paint Film Cross-Cut Testers Based on Different Adhesion Testing Requirements
This article mainly discusses how to choose the appropriate paint film cross-cut tester based on different adhesion testing requirements.
Evaluation of Coating Adhesion Grade by Cross-Cut Tester Combined with Tape Method
This article introduces the method of evaluating coating adhesion using a paint film cross-cut tester combined with the tape method.