The internal diameter surface thickness gauge uses ultrasonic or eddy current probes to contact the curved inner wall of pipelines or containers, emits detection signals, receives echoes, and calculates the material thickness. It is used to measure the coating and corrosion conditions of the inner walls of pipelines, providing direct thickness data for inner wall surfaces in chemical pipeline maintenance and storage tank inspections.
Selection
When selecting, consider matching the probe principle to the type of material being tested: use eddy current probes for metals and ultrasonic probes for non-metals. Confirm the probe's bending adaptability based on the pipeline's curvature radius, and ensure the measurement range covers the expected thickness. Environmental temperature affects accuracy, so waterproof models are required for humid environments. The operation interface should be simple, and the probe size must match the inspection space.

Terms

Standards

Instruments

It can measure concave-convex surfaces with a radius of curvature greater than 6mm, compatible with planar and cylindrical measurements, with a minimum measurement aperture of 2mm, and a dedicated platform to achieve stable detection.

$ 461.00

Using 5MHZ Frequency and 14mm diaMeter design, support 3.0~ 200mm steel material measurement, minimum pipe diaMeter 30mm, suitable for high temperature environment, temperature measurement range of 450 ℃, to ensure accurate thickness detection.

$ 190.00

Suitable for 300 ℃ high temperature material thickness measurement, range 2.0~ 100mm, diaMeter 14mm, minimum diaMeter 30mm, 5MHz Frequency to achieve accurate measurement.

$ 199.00

Adopt magnetic Induction principle measurement, thickness range 0~ 1000μm, error +/- 3%, with low voltage prompt function, support split Probe and customized range, adapt to different curvature matrix measurement needs.

$ 243.00

Using eddy Current thickness measurement principle, Measurement range 0-1000μm, resolution 0.1μm, minimum measurable convex curvature 3mm, with automatic shutdown and low voltage prompt function.

$ 267.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Using magnetic Induction Measuring method, range 0~ 5mm, error +/- 5%, can measure a variety of non-ferrous magnetic coatings, suitable for different curvature substrate surface.

$ 359.00

Mechanical design for measurement on any surface, using hardened stainless steel, measurement disc diaMeter 50mm, thickness 11mm, equipped with aluminum free swirl/spin rollers, reading accuracy +/- 2μm.

$ 848.00

Measurement range of 3.0-600 mm with 2MHz Frequency and 22mm diaMeter design, high penetration capability, suitable for thickness detection of a variety of good conductor materials.

$ 211.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Measuring methods of magnetic Induction and eddy Current, covering 0-1500 μm range, resolution up to 0.1 μm, support continuous and single Measurement mode, statistical function and 500 sets of data storage, suitable for different curvature radii and substrate Film thickness scenes.

$ 243.00

Measurement range 0~ 1250μm, error +/- 3%, can be one point and two point calibrated, suitable for the minimum F7mm measurement surface and 1.5mm curvature radius of the substrate.

$ 157.00

Measurement range 0-20mm, accuracy 0.01mm, contact pressure 20 +/- 0.5kPa, contact surface diaMeter 35.7mm, suitable for a variety of sheet material thickness detection, to ensure high parallelism and Precision.

$ 493.00

Measurement beam of light diaMeter 1.5mm, measurement window 4mmx2mm, suitable for facet and small curvature surface measurement, low energy consumption single battery can last for more than 58 hours.

$ 428.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.