Chloride Ion Titrator

The chloride ion meter detects the concentration of chloride ions in a solution using the electrode potential method. The electrode reacts with chloride ions to generate a potential difference, and the instrument measures this potential and converts it into a concentration value. It is used for water quality monitoring, food salt content detection, and industrial process control to ensure that chlorine levels comply with standards.
Selection
When selecting, consider that the measurement range should cover the sample concentration, and the accuracy should meet the detection requirements. The electrode type should be suitable for liquid or solid samples, and automatic temperature compensation ensures stable results. The operation interface should be simple, the maintenance cycle should align with usage frequency, and the cost of consumables should match the budget.

Terms

Standards

Instruments

Adopt automatic potential Titrimetric method, built-in standard method to directly read the results, support silver nitrate (AgNO3) calibration and blank experiment, data management can store 200 sets of results, titration analysis Repeatability of 0.20%.

$ 3667.00

Designed for chloride ion composite ElectRode, provides stable calibrating performance, Encasement size 250ml, to ensure long-term use Reliability and measurement conformity.

$ 110.00

Specially designed for lead chloride ion composite ElectRode, providing stable reference potential to ensure the accuracy of ion measurement, Encasement capacity 250ml, suitable for routine laboratory testing.

$ 99.00

1000Pppm standard concentration to ensure the accuracy of calibrating, PTFE material solution bottle effectively prevent contamination, 480mL capacity to meet the needs of conventional use, universal design for a variety of ion measurement scenarios.

$ 135.00

With manual and automatic temperature compensation function, Measurement range 0-6 PCL, resolution up to 0.01 PCL, easy operation and intuitive and accurate digital display, suitable for a variety of water quality monitoring scenarios.

$ 382.00

With 5 point Adjustment, Measurement accuracy 0.5% F.S., Support automatic temperature compensation and end point locking, can store 500 sets of data and comply with GLP specifications, provide a variety of concentration unit selection.

$ 696.00

ElectRode composite design, Measurement range, Response fast and stable, equipped with special reference filling solution and calibrated solution to ensure measurement accuracy, suitable for a variety of water quality analysis scenarios.

$ 273.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 1% F. S, suitable for a variety of Ion concentration detection.

$ 864.00

Concentration 1000ppm of copper ion standard solution, PTFE bottle Encasement, capacity 480mL, suitable for daily ion calibrating applications.

$ 135.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 0.5% F. S, suitable for a variety of Ion concentration detection.

$ 864.00

Universal ion standard solution concentration 1000ppm, suitable for daily ion calibrating, PTFE bottle Encasement, capacity 480mL, to ensure calibrating accuracy and Stability.

$ 135.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ElectRode, Measurement accuracy +/- 0.5% F.S., can store 1000 sets of data, suitable for a variety of Ion concentration detection.

$ 864.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, expands memory to store 1000 sets of data, Measurement accuracy of +/- 1% F.S.

$ 864.00

Measurement range of 1~ 2 × 10, using BNC plug design, matching pH and ion Meter, easy operation and fast Response, suitable for accurate Ion concentration detection.

$ 191.00

General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.

$ 135.00

Articles

Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Automatic Potentiometric Titration for Rapid Detection of Chloride Ion Content in Cement
This article introduces a method for rapidly detecting the chloride ion content in cement using an automatic potentiometric titrator. Excessive chloride ions can corrode steel reinforcement and affect the lifespan of concrete, making accurate detection crucial.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Key operational points for determining chloride ion content in water using automatic potentiometric titrators
This article introduces a method for measuring chloride ions in water using an automatic potentiometric titrator. It is based on silver nitrate titration, where the endpoint is automatically determined by a sharp change in electrode potential, offering greater accuracy and higher automation compared to traditional methods.