Constant Temperature Heating Apparatus

The constant temperature heating device generates heat through electric heating elements, with a temperature control system maintaining the set temperature. It is used for laboratory operations such as sample heating, drying, and reactions, providing a stable thermal environment for processes like material curing and solution evaporation.
Selection
Select the heating platform area based on the sample container size, match the heating power according to the temperature range, and consider temperature control accuracy and uniformity. Take into account corrosion-resistant materials and safety protection functions, and choose the corresponding brand and model within the budget.

Terms

Standards

Instruments

With dual functions of refrigeration and heating, Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.2 ℃, support multi-stage programming and internal and external circulation, equipped with over-temperature alarm and liquid level protection.

$ 1648.00

Temperature range -10~ 100 ℃, Temperature Stability +/- 0.02 ℃, using imported Compressor and SUS304 stainless steel heating device, support internal and external circulation, can accommodate 500ml beaker directly inserted into use.

$ 1361.00

Glass sealing barrel wall thickness of 15mm, automatic constant pressure gas without manual operation, vacuum accuracy level 1, support 0~ -100kPa range, suitable for a variety of Encasement sealing test.

$ 764.00

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

Temperature control accuracy of +/- 0.1 ℃, temperature range -5~ 100 ℃, stainless steel corrosion resistance, compact structure to save space, suitable for a variety of experimental environment auxiliary heating.

$ 903.00

Using French Taikang fully enclosed Compressor refrigeration, Temperature Uniformity ≤ +/- 2 ℃, equipped with 7-inch large screen controller, independent temperature limit alarm system to ensure safety, multi-wing air supply circulation to avoid temperature dead angle.

$ 5076.00

Adopt 7.0 inch large screen controller, temperature control accuracy +/- 0.1 ℃, humidity control accuracy +/- 1% R.H., equipped with independent temperature limit alarm system, support multi-wing air supply cycle to ensure uniform temperature.

$ 6157.00

The use of air circulation heating makes the temperature distribution uniform, the temperature fluctuation range is less than 0.5 ° C, the internal non-uniformity is about 1.0 ° C. It has PID adjustment and thermostatic timing functions, and the temperature control is accurate and stable.

$ 2333.00

Maximum stirring capacity 5 liters, Heating power 550 watts, Microcomputer control technology to ensure constant Rotation speed, external Temperature Sensor accurate control of solution temperature, with temperature deviation protection and anti-corrosion design.

$ 388.00

The maximum heating temperature is 300 ° C, the stirring speed is 0~ 1250rpm, the stirring time and thermostatic temperature can be set, and the external temperature sensor automatically controls the temperature to prevent the stirringRod from stalling.

$ 240.00

Adopt French Taikang Compressor refrigeration system, Temperature Uniformity ≤ +/- 2 ℃, equipped with independent temperature limit alarm and double-decked Glass observation window, support 0~ 9999 minutes timing and 50mm test hole.

$ 8820.00

The use of air circulation heating makes the temperature distribution uniform, the temperature fluctuation is less than 0.5 ℃, the internal non-uniformity is about 1.0 ℃, equipped with brushed stainless steel liner for easy cleaning, and supports thermostatic timing function.

$ 1816.00

Maximum heating temperature 400 ° C, stirring speed 0~ 1250rpm, support external temperature sensor automatic thermostatic, key Rotation speed setting to prevent stirringRod stall, large screen LCD display temperature and stirring status.

$ 259.00

Using high temperature non-alkali fiberglass insulation material, the highest temperature 380 ℃, with internal and external dual Sensor temperature measurement function, large heating area and rapid heating, excellent thermal insulation effect.

$ 151.00

Tack testing to assess adhesion by measurement of displacement or peeling time under specified weight. With thermostatic test chamber, multi-national standards are supported and the operation process is clear.

$ 2090.00

Articles

Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Heating and blade coating of gel electrolyte films for zinc-ion batteries.
This article introduces the heating doctor-blade coating method for preparing gel electrolyte films in zinc-ion batteries. The method involves spreading a slurry onto a substrate using a doctor blade, followed by heating to evaporate the solvent and form a film.
Heating coating machine is used for the doctor-blade coating of gel electrolyte films in zinc-ion batteries.
This article introduces the blade coating process for preparing gel electrolyte films for zinc-ion batteries using a heated coating mechanism. By controlling parameters such as temperature, coating speed, and gap height, this method enables the fabrication of films with uniform thickness and smooth surfaces.
The heating film coater applies thick-film resistor paste onto the ceramic substrate.
The heating coating machine is used to apply thick film resistor paste on ceramic substrates. It reduces the viscosity of the paste through a heating platform and ensures uniform coating in conjunction with the coating head.
Vicat Softening Point Tester evaluates the heat deformation resistance of resins.
The Vicat softening point tester is used to measure the thermal deformation resistance of resins. It heats and applies pressure to the specimen until it deforms by 1 millimeter, recording the temperature at that point as the softening point.
Muffle furnace is used for the determination of coating loss on ignition and ash content.
A muffle furnace is a laboratory heating device used to determine the loss on ignition and ash content of coating materials. By incinerating the sample at high temperatures, the organic components decompose and volatilize, leaving behind inorganic residues as ash.
Thermogravimetric Analyzer for Determining the Solid Content of Varnish
The principle of determining the solid content of varnish using a thermogravimetric analyzer is as follows: when the sample is heated, volatile solvents and moisture evaporate, leading to a decrease in mass, while the remaining solid mass stabilizes. The solid content is calculated by comparing the initial and final mass ratios.
Effect of Platform Temperature on Surface Drying Time of Waterborne Polyurethane Coatings in Heated Automatic Film Applicators
This study investigates the influence of the platform temperature of a heated automatic film applicator on the surface drying time of waterborne polyurethane coatings. The experiments reveal that as the platform temperature increases, the surface drying time of the coating significantly decreases, showing a negative correlation between the two.
Application of Vacuum Heating Integrated Coating Machine in the Preparation of High-Temperature Curing Coating Samples
This article introduces the application of the vacuum heating integrated film coater in the preparation of samples for high-temperature curing coatings. The equipment reduces bubbles in the coating by creating a vacuum environment and integrates programmable heating and curing functions, enabling precise temperature control to promote the chemical cross-linking of the coating and form a uniform film.