Artificial Climate Regulation Chamber

The artificial climate control chamber simulates natural environmental conditions through temperature control, humidity control, and lighting systems. It is used for experiments such as material aging tests, product stability evaluations, and biological cultivation, helping to observe changes in samples under specific environmental conditions.
Selection
When selecting an artificial climate chamber, it is necessary to consider the temperature range, humidity control accuracy, light intensity, chamber size, and energy consumption parameters. These factors should align with the requirements of the experimental samples and spatial conditions to ensure long-term operational stability and ease of maintenance.

Terms

Standards

Instruments

Adopt stainless steel air duct and centrifugal fan, the wind speed is adjustable, the dust concentration is 2.0~ 4.0kg/m ³, support vertical circulation and dust drying, ensure test uniformity and data accuracy.

$ 8093.00

Adopt stainless steel air duct and centrifugal fan, talc concentration 2.0~ 4.0kg/m ³, support dust drying and vibration function, ensure test data accuracy and uniform dispersion.

$ 8674.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, temperature fluctuation is only +/- 0.5 ℃.

$ 12015.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, Temperature Fluctuation control within +/- 0.5 ℃.

$ 16017.00

The heating wire is used to achieve rapid heating, the temperature fluctuation is only +/- 0.5 ℃, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, supports dynamic static test mode, and meets a variety of test needs.

$ 14419.00

Using heating wire and PT100 temperature transducer, Temperature Fluctuation +/- 0.5 ℃, support 0~ 999H light time setting, 360 degree swirl/spin sample holder and imported concentration Analyzer to ensure test accuracy.

$ 11369.00

Using electric heating wire to achieve rapid and uniform heating, equipped with 360-degree swirl/spin sample holder and 12-16mm/s gas flow rate, support 0-9999 hours time setting, with leakage overtemperature multiple safety protection.

$ 13209.00

Adopting stainless steel air duct and centrifugal fan, the wind speed can be adjusted, the dust concentration is 2.0~ 4.0kg/m ³, and it has the function of vertical circulation air flow and dust drying to ensure the accuracy and uniform dispersion of test data.

$ 10353.00

Adopt stainless steel air duct and centrifugal fan, dust concentration 2.0~ 4.0kg/m ³, liner size 1000 * 1500 * 1000mm, support vertical circulation air flow and dust drying function, ensure accurate and reliable test data.

$ 9465.00

Volume 800L, Temperature range 4-50 ℃, light intensity 0-30000LX, support 30 sets of program settings, with independent temperature limit alarm system and mirror stainless steel liner design.

$ 7180.00

Adopt stainless steel air duct and vertical circulation air flow system, equipped with frequency converter to adjust the wind speed, dust concentration 2.0~ 4.0kg/m ³, built-in vibration and drying device to ensure the accuracy of test data.

$ 6334.00

With six-level adjustable light and 0.1 ℃ Temperature resolution, it can simulate the change of day and night temperature and Humidity, and supports 30 sets of program settings to ensure the safe and stable operation of the experiment.

$ 1845.00

Using refractive index Measurement principle, automatic temperature compensation 0-40 ℃, Measurement time of about 1.5 seconds, only 100 μ L sample volume, support PSU, ppt and specific gravity three unit conversion, stainless steel sample Chamber corrosion resistance.

$ 567.00

The 300-liter volume is equipped with a two-sided lighting system, the Illumrination degree can be adjusted to 15000LX, and the mirrored stainless steel liner is easy to clean. It can set 30 sets of programs and support 180 hours of continuous operation.

$ 2229.00

Imported Compressor to achieve high efficiency and low energy consumption operation, equipped with six-stage adjustable lighting system, Temperature range 4~ 50 ℃, mirror stainless steel liner for easy cleaning, support 30 sets of program settings and independent temperature limit alarm.

$ 2052.00

Articles

Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.