The EX concentration detector measures the absorption intensity of light at specific wavelengths by the substance being tested through sensors, and calculates the concentration value based on the Lambert-Beer law. It is used for real-time monitoring of changes in the content of substances such as solvents and pigments during production processes, ensuring stable ratios in scenarios like paint formulation and printing ink quality control.
Selection
When selecting, consider that the measurement range covers the actual sample concentration, the detection accuracy meets the allowable process error, and the probe material is resistant to corrosion by the measured medium. Environmental temperature effects need to be compensated for, and regular calibration with standard solutions is required. The interface should be compatible with the existing control system, and maintenance parts should be readily available.

Terms

Standards

Instruments

With wireless 4G/WIFI networking function, support remote monitoring and Data storage; Adopt diffusion gas circuit design, Response Time T90 ≤ national standard; With LED, sound, vibration and screen flash four Alarm modes, IP66 Protection Rating.

$ 231.00

Modular design with low power consumption, intelligent Sensor detection technology, Explosion-proof level Ex db IIC T6 Gb, Protection Rating IP66, support 4-20mA, RS485 and switching signal output, Response Time ≤ 30S, suitable for a variety of industrial environments.

$ 835.00

Modular design with low power consumption, intelligent Sensor detection technology, Explosion-proof level Ex db IIC T6 Gb, Protection Rating IP66, support for multiple signal output and wireless transmission.

$ 887.00

Pump suction sampling, detection of CO, H2S, O2, EX four gases, accuracy ≤ +/- 3%, equipped with 4000mAh large capacity battery and 2.4 inch color screen, support Data storage and export, Protection Rating IP65.

$ 469.00

Using catalytic combustion Sensor, range 0~ 100% LEL adjustable, with infrared remote control debugging and 4~ 20mA output, support alarm record query and automatic temperature compensation, suitable for hazardous environment.

$ 152.00

Pump suction sampling, detection accuracy ≤ +/- 3%, Response Time T90 ≤ 20s, built-in 4000mAh battery to support long-term work, with Data storage and export functions, Protection Rating IP65 to adapt to harsh environments.

$ 432.00

Pump suction sampling, detection accuracy ≤ +/- 3%, Response Time T90 ≤ 20 seconds, built-in 4000mAh large capacity battery, support data storage and export, with IP65 Protection Rating.

$ 393.00

Using catalytic combustion detection principle, the range covers 0-100% LEL, Response Time ≤ 30 seconds, with flameproof structure and a variety of signal output, support remote monitoring and infrared remote control operation, through a number of international safety certifications.

$ 190.00

Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.

$ 106.00

It can simultaneously detect 4 kinds of gases and integrate temperature and humidity monitoring, support diffusion and pump sampling methods, with a 10-Meter visual distance high definition color screen, realize remote monitoring and paraMeter configuration through the Internet of Things, and adapt to the working environment of -40~ 55 ℃.

$ 393.00

Sensor imported to ensure high Sensitivity and stability, Response Time ≤ 15 seconds, with 6000 alarm record query function, providing sound and light vibration triple alarm and super high waterproof design.

$ 122.00

Modular design with low power consumption, Explosion-proof level Ex db IIC T6 Gb, Protection Rating IP66, support 4-20mA, RS485 and switching output, Response Time ≤ 30 seconds, can detect NH3, CL2, CO2 and EX gases.

$ 1054.00

Pump suction sampling, Response Time T90 ≤ 20s, can store 120000 sets of data, equipped with 2.4 inch color screen display concentration value, support Humidity detection and data export function.

$ 545.00

Using electrochemistry principle to detect 0~ 30% VOL oxygen concentration, with 4G/WIFI wireless communication function, support temperature compensation algorithm and a variety of filtering algorithms, Response fast and accurate data.

$ 282.00

Using catalytic combustion Sensor, range 0~ 100% LEL adjustable, with automatic zero correction and temperature compensation function, support 4~ 20mA and RS485 output, infrared remote control safety adjustment.

$ 122.00

Articles

How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Selection Basis for Karl Fischer Titration: Volumetric vs. Coulometric Methods
There are two methods for Karl Fischer moisture titrators: volumetric and coulometric. The volumetric method calculates moisture by measuring the volume of a reagent with a known concentration that is consumed, making it suitable for samples with higher moisture content, such as those in the range of a few thousandths or more.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Valley Beater in Pulp Laboratory Beating
The Valley beater is a device used in laboratories to simulate industrial beating processes. It modifies the morphology of pulp fibers through mechanical action, thereby influencing paper properties. During operation, parameters such as beating pressure, pulp consistency, and beating time must be controlled, with the beating degree serving as a quantitative measure of the effect.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
The role of a reflection densitometer in controlling printing ink concentration.
The reflection densitometer measures the light reflectance of the ink layer and converts it into a density value, thereby objectively reflecting the thickness and concentration of the ink layer. In printing, it is used to monitor solid density, ensuring stable ink supply, replacing subjective judgment, and enabling data-driven control.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
Application of Salt Spray Test Chambers in Corrosion Resistance Testing of Automotive Components
The salt spray test chamber simulates a salty and humid environment to accelerate the testing of the corrosion resistance of automotive components. Its principle is based on electrochemical corrosion, allowing for the control of key parameters such as salt concentration and temperature.
If the standard disintegrator procedure for fiber dissociation is not done correctly, the first step of paper strength testing is already compromised.
Fiber disintegration is the first step in paper strength testing. If the operation is not standardized, such as inaccurate concentration, excessive time, or incorrect rotational speed, it can lead to fiber breakage or uneven dispersion, resulting in inaccurate strength data for the prepared hand sheets.