Contact Moisture Meter

The contact moisture analyzer measures moisture content by contacting the sample with a probe and utilizing changes in resistance or capacitance. It is used for rapid detection of moisture in solid or powdered materials and is suitable for routine moisture monitoring in production sites and laboratories.
Selection
When selecting a contact moisture meter, consider matching the probe type to the material form, ensuring the measurement range covers the sample's moisture content, the calibration function adapts to different materials, the robust structure suits the usage environment, and the ease of operation meets the user's skill level.

Terms

Standards

Instruments

Using electromagnetic wave scanning technology, high frequency scanning depth 50mm, Measurement range 0-99.9%, Response Time 1 second, no contact can be measured without damage to the internal moisture content of the object.

$ 225.00

Baseline and droplet contours are automatically recognized by machine vision, and contact angles are calculated based on Laplace equation quadratic Linear dispersion fitting. Measurement range is 0-180 °, accuracy is 0.1 °, and dynamic contact angle measurement and surface energy calculation are supported.

$ 3462.00

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Measurement range 0-4mm, contact pressure 100 +/- 10kPa, contact area 200 +/- 5mm ², measurement plane parallelism ≤ 0.0005mm, suitable for a variety of sheet material thickness accurate determination.

$ 403.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Measurement range 0-4mm, contact pressure 100kPa, contact area 2cm ², equipped with digital dial Meter to achieve accurate thickness measurement.

$ 688.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Ring quartz tungsten halogen infrared lamp is used for internal heating, with a unique temperature control system to achieve uniform heating, with 120g Capacity and 0.02% moisture readability, real-time monitoring of moisture changes and support for multiple sets of data storage.

$ 359.00

Ring quartz tungsten halogen infrared Heating mode is used to directly heat from the inside of the material, and a unique temperature control system is used to achieve uniform heating. With 0.02% moisture Readability and 50g weighing capacity, real-time monitoring of moisture changes ensures accurate results.

$ 330.00

Measurement range 0-4mm, contact pressure 100kPa, equipped with dial indicator mechanism, can achieve accurate thickness detection, suitable for a variety of sheet materials.

$ 535.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

CCD camera system to achieve 1280 × 1024 resolution image analysis, support 0~ 180 ° contact angle and 0~ 400mN/m surface tension measurement, with dynamic contact angle analysis and solid surface energy estimation function.

$ 4077.00

The static drop method, droplet method and inclined plate method are used for measurement of dynamic contact angle, with automatic sampling, automatic surface tension analysis and automatic contact angle analysis functions. Degree of automation is high and Measurement accuracy is high.

$ 6205.00

Articles

Roughness Measurement Instrument Selection: Contact vs. Non-Contact
This article introduces the differences between contact and non-contact methods when selecting a roughness measuring instrument.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Principles and Selection of Film Thickness Measurement Instruments
This article introduces the principles and selection methods of thin film thickness measurement instruments. The measurement principles are mainly divided into contact and non-contact methods, which calculate thickness by detecting the differences in the thin film's response to physical signals.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.