DIN Standard Viscosity Cup

The DIN viscosity cup determines the viscosity of coatings by measuring the time required for the coating to flow out from a small hole at the bottom of the cup. It is used for rapid detection of flowability in coating production and application, helping to control coating uniformity. It is suitable for Newtonian fluids such as paints and inks.
Selection
When selecting a DIN viscosity cup for coatings, consider the viscosity range of the material being tested to match the aperture size of the cup. Choose brass or stainless steel based on the standard operating environment. Ensure the cup body is free from deformation and the orifice is smooth. Verify that the product complies with the DIN 53211 standard.

Terms

Standards

Instruments

Outflow aperture 1.9mm, viscosity measurement range of 10~ 35cSt, aluminum alloy Cup body and stainless steel pore structure durable, in line with ASTM D1200 standard.

$ 167.00

Flow hole diaMeter 6mm, Cup height 74mm, stainless steel material, in line with international standards, suitable for Newtonian or near newtonian fluid, providing accurate viscosity assessment.

$ 587.00

Outflow aperture 3.4mm, viscosity measurement range 49~ 220cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

The filter diaMeter of 1-8mm can be freely replaced, the Cup mouth annular groove is designed to store overflow liquid, titanium anodic oxidation aluminum Cup body with stainless steel filter positioner, the distance between the outflow hole and the liquid level should be greater than 100mm.

$ 436.00

1-8Mm pore diaMeter stainless steel filter can be replaced to meet different viscosity range tests; Cup mouth annular groove design can store overflowing liquid; Cup body is made of titanium anodic oxidation aluminum material, durable and easy to clean.

$ 422.00

The 1mm-8mm pore size filter can be replaced to meet the viscosity range test of 96~ 683cSt; the annular groove of the Cup mouth is designed to store overflowing liquids, and the Cup body is easy to clean without sinkage. It is equipped with a stainless steel filter positioner.

$ 403.00

Aperture 4.12mm, viscosity measurement range of 70~ 370cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

DiaMeter 1mm outflow hole design, in line with DIN53211 standard, using stainless steel material to improve Abrasion Resistance and rust resistance performance, suitable for testing requirements of different viscosity Coatings.

$ 154.00

Adopt replaceable filter design, support 1-8mm aperture selection; Cup annular groove can store overflowing liquid, Cup wall has no clean dead angle; comply with DIN53211 standard, with unique serial number for easy tracking.

$ 441.00

Using stainless steel aperture 5.20mm, viscosity measurement range of 200~ 1200cSt, aluminum alloy Cup body sturdy and durable, in line with ASTM D1200 standard, suitable for laboratory accurate measurement of fluid viscosity.

$ 170.00

Conform to DIN 53211 standard, evaluate viscosity by measuring 100ml liquid outflow time, pore size 8mm, applicable viscosity range 1200~ 3000cst, outflow time 25~ 150s.

$ 130.00

Conform to DIN 53211 standard, evaluate viscosity by measuring 100ml liquid outflow time, 4mm pore size design is suitable for 112~ 685cSt viscosity range, outflow time is 25~ 150 seconds, anodic oxidation aluminum alloy Cup body corrosion resistance.

$ 130.00

In line with DIN 53211 standard, the outflow time is 25~ 150s, the viscosity range is 15~ 30cSt, and the aluminum alloy Cup body and stainless steel nozzle are used to quickly test low viscosity liquids.

$ 135.00

Replaceable 1-8mm aperture stainless steel filter, Cup mouth annular groove design to store overflow liquid, Cup body made of titanium anodic oxidation aluminum, outflow hole diaMeter 6mm, easy to clean and equipped with a unique serial number.

$ 420.00

Made of stainless steel, filter diaMeter 4mm, viscosity measurement range 96~ 683cSt, outflow time 25~ 150 seconds, equipped with a unique serial number to ensure traceability, in line with international standards.

$ 749.00

Articles

Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.