Using split Sensor design, Temperature Measurement range -10~ 50 ℃, Humidity Measurement range 5~ 98% RH, support ℃/F unit conversion, equipped with 9V battery power supply.
The equipment temperature range -40~ 70 ℃, Humidity Measurement range 20%~ 90% RH, temperature error +/- 1 ℃, using the principle of electrical change capacitance or resistance to achieve fast and accurate measurement, portable design only weighs 114g.
With split Probe design, Temperature Measurement range covering -10~ 50 ℃, can be extended to 1000 ℃, Humidity Measurement range 5~ 98% RH, error +/- 1.5 ℃ and +/- 5%, support unit conversion, portable and durable.
Built-in Air Temperature Humidity Sensor and K-Connector, with armored cable and magnetic surface temperature sensor to prevent accidental detachment, supports a variety of optional Probe conversions.
Capacitive polymer film Humidity Sensor and semiconductor temperature sensor, with temperature compensation and nonlinear correction function, can store 8000 sets of data, support USB connection and automatic calculation of average value, MAX Maximum and MIN Minimum, compact and easy to carry.
Humidity measurement range -10~ 60 ℃ and 10~ 95% RH, Sampling time 0.4 seconds, Automatic recording MAX Maximum, MIN Minimum and Final Measured value, Built-in Sensor and support USB data output.
Imported Humidity Sensor and Compressor, temperature control accuracy of +/- 0.5 ℃, humidity deviation +/- 3% RH, equipped with independent temperature limit alarm system and test hole to ensure the safety and reliability of the experiment.
Adopt TMHM equilibrating Conditioning method, temperature control accuracy up to +/- 0.5 ℃, equipped with imported Humidity Sensor and independent temperature limit alarm system, 25mm test hole on the left for easy operation.
Sensor imported, temperature control accuracy of +/- 0.5 ℃, Humidity deviation of +/- 3% RH, equipped with independent temperature limit alarm system and test hole, to ensure safe and stable operation of the experiment.
Humidity controller with dry and wet bulb type or electric kiln type, temperature fluctuation +/- 0.5 ℃, humidity deviation +/- 3% RH; with independent temperature limit alarm, Compressor multiple protection and water shortage protection functions to ensure safe operation.
Using imported Sensor and TMHM equilibrating Conditioning method, temperature control accuracy of +/- 0.5 ℃, humidity control accuracy of +/- 3% RH, with independent temperature limit alarm system to ensure experimental safety.
Temperature range -10~ 70 ℃, Humidity Control Range 40~ 95% RH, using imported Sensor and microcomputer controller, with independent temperature limit alarm system, can be equipped with RS485 interface and test hole.
Using External Sensor, Humidity accuracy of +/- 0.2 ℃ and +/- 2.5% RH respectively, Humidity Response Time as fast as 15 seconds. With Bluetooth wireless setting and download, weatherproof shell, support mobile end real-time viewing and data sharing.
Measurement range, Humidity 10.0-95% RH, Temperature 0.0-60 ℃. High accuracy with film polymer capacitive Sensor. Battery error prevention system for measurement Reliability.
The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.