Laboratory High-purity Water Purification System

The laboratory high-purity water system removes impurities from water through pre-treatment, reverse osmosis, ion exchange, and ultrafiltration, producing purified water with a resistivity of up to 18.2 MΩ·cm. It is used for instrument cleaning, reagent preparation, and experimental analysis to avoid interference from ions in water affecting test results.
Selection
Select a primary/secondary pure water or ultrapure water model based on the grade of water required for experiments; determine the storage capacity and distribution unit by considering daily water consumption and water collection methods; match the pretreatment configuration with the quality of the source water; and pay attention to consumable replacement costs and system maintenance convenience.

Terms

Standards

Instruments

The principle of thermal radiation is used to keep the liquid phase temperature below the boiling point, avoid boiling water droplets, and complete gas-liquid separation; the double condensation cycle design improves the extraction efficiency of pure water, the output of pure water reaches 400-500ml/hour, and the Heating power is 800-1000W to ensure that no heavy metals are detected.

$ 432.00

The principle of thermal radiation is used to keep the liquid phase temperature below the boiling point, avoid boiling water droplets, and achieve complete gas-liquid separation; the output of pure water is 800-1000ml/hour, and the Heating power is 1500-2000W to ensure that no heavy metals are detected.

$ 548.00

Measurement range 0.23 nm g/L to 23 g/L, temperature compensation 5~ 50 ℃, suitable for high purity water and industrial drainage sodium ion concentration determination, repeatability error does not exceed 0.03pNa.

$ 262.00

The eight-stage deep purification system ensures that the water quality is pure, the resistivity of the pRoduced water is 18.25MΩ .cm, and it is equipped with an intelligent Control system to realize automatic monitoring and a variety of water intake modes to meet the strict experimental requirements.

$ 4511.00

The principle of thermal radiation is used to keep the liquid temperature below the boiling point and avoid water droplets in the gas. The double condensation cycle design improves the extraction effect of pure water, and the output of pure water reaches 800-1000ml/hour. No heavy metals are detected by flameless atomic absorption analysis.

$ 548.00

The water pRoduction rate reaches 5L/h, the eight-stage purification system includes reverse osmosis (RO) membrane and ultra-pure polishing column, the desalination and sterilization rate is over 99%, supports intelligent control and a variety of water intake modes, suitable for laboratory environment use.

$ 3543.00

The water pRoduction rate is 10L/h, and the eight-stage purification system includes reverse osmosis (RO) membrane and ultra-pure polishing column, providing 18.25MΩ. cm ultra-pure water quality, supporting multiple water intake modes and intelligent control functions.

$ 4027.00

With manual and automatic temperature compensation function, Measurement range 0-6 PCL, resolution up to 0.01 PCL, easy operation and intuitive and accurate digital display, suitable for a variety of water quality monitoring scenarios.

$ 382.00

Measurement principle of hanging water method, density accuracy of 0.001g/cm ³, support one key zero and temperature compensation function, can cycle display K number and purity percentage, and have mixed specific gravity determination and over-limit prompt function.

$ 441.00

Measurement accuracy of 0.001g/cm ³, support temperature compensation and mixed specific gravity measurement, can cycle display K number and purity%, with over-limit prompt function, operation only needs two steps.

$ 338.00

Double shell structure with Air-Cooled system to achieve rapid cooling, 51 program temperature control system to ensure +/- 1 ℃ accuracy, the highest Operating temperature of 1700 ℃ and equipped with corundum tube to ensure high temperature Stability.

$ 3640.00

With 40L/H water pRoduction capacity and 18.2MΩ · cm resistivity, 5.1-inch large screen real-time display of water quality, automatic circulation and disinfection system to extend the life of consumables, support regular quantitative water intake, all-plastic shell rust-proof and durable.

$ 2205.00

Double shell structure with cold air system to achieve rapid cooling, 51 program temperature control system to ensure Temperature control accuracy +/- 1 ℃, the highest Operating temperature of 1400 ℃, support stable operation in a variety of atmosphere environment.

$ 3107.00

The circular stainless steel liner is used to prevent condensation and dripping, the copper tube bell mouth is designed with good air tightness and low water consumption, and the special high temperature foaming material improves the pressure life. It is equipped with a 16L large-capacity water Tank and an automatic water replenishment system.

$ 4269.00

Equipped with 7-inch capacitive Touchscreen, intuitive operation; Integrated four-ring Probe, Measurement range is wide and stable, support a variety of compensation algorithms; Large data recording capacity, support a variety of export methods; Suitable for high-purity water, natural water and other water quality measurement.

$ 2176.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Standard Procedure for Printability Tester in Evaluating Ink Transfer Performance
This article introduces the standard procedure for evaluating ink transfer performance using a printability tester. The transfer performance of ink directly affects print quality, and standardized operations can enhance the reliability of test results.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.