Medium-speed stirrer

The medium-speed stirrer drives the blades to rotate via an electric motor, generating vortices and shear forces in liquids or mixtures to achieve uniform mixing, dissolution, or dispersion. It is commonly used in laboratory sample preparation, paint formulation, and chemical reaction processes to ensure thorough contact and reaction of materials.
Selection
When selecting a medium-speed stirrer, consider matching the rotational speed range with the viscosity of the material, determine the length of the stirring rod based on the container size, check whether the motor power meets the requirements for long-term operation, confirm whether the speed control method supports precise adjustment, and inspect the material's corrosion resistance to adapt to different chemical environments.

Terms

Standards

Instruments

With 70mm diaMeter slurry and 8mm Rod diaMeter design, the mixing performance is mild, suitable for medium and low speed operation, can effectively handle the medium that needs gentle stirring, and avoid excessive turbulence.

$ 99.00

Speed range 30-2200rpm, Max. Torque 60N.cm, supports medium and high viscosity liquid mixing, with automatic torque adjustment and overload protection functions, can run continuously for a long time.

$ 690.00

Speed range 30-2200rpm, Max. Torque 60N.cm, supports medium and high viscosity liquid mixing, with overload protection and automatic torque adjustment function, can operate safely for a long time.

$ 701.00

Speed range 30-2200rpm, Max. Torque 60N.cm, supports medium and high viscosity liquid mixing, with overload protection and automatic torque adjustment function, can run continuously for a long time.

$ 683.00

The stainless steel material ensures durability, and the paddle width of 70mm and Rod length of 350mm are designed for medium and high speed mixing, generating axial flow and local shear force, suitable for a variety of mixing needs.

$ 102.00

Speed range 30-2200rpm, Max. Torque 60N.cm, brushless DC motor can run for a long time, with automatic overload protection and LCD screen display function, suitable for mixing medium and high viscosity samples.

$ 696.00

Speed range 30-2200rpm, Max. Torque 40N.cm, supports medium and high viscosity Sample Handling, with automatic protection function and a variety of Impeller options to adapt to different experimental needs.

$ 583.00

Speed range 30-2200rpm, Max. Torque 60N.cm, supports medium and high viscosity sample mixing, with overload protection and automatic torque adjustment function, can run continuously for a long time and is safe and reliable.

$ 699.00

Speed range 30-2200rpm, Max. Torque 60N.cm, supports medium and high viscosity liquid mixing, with automatic overload protection and self-locking chuck design, can run continuously for a long time and is safe and reliable.

$ 691.00

The stainless steel structure with a blade width of 70mm and a Rod length of 300mm can operate at medium and high speed, generating axial flow from top to bottom and local shear force, which is suitable for mixing various viscous liquids.

$ 101.00

Speed range 30-2200rpm, Max. Torque 40N.cm, DC brushless motor can run for a long time, with overload automatic protection and LCD screen display, suitable for mixing needs of medium and high viscosity samples.

$ 570.00

The blade width is 70mm and the height is 1.5mm, the Rod diaMeter is 6mm and the length is 350mm, the stainless steel material is resistant to corrosion, and the medium and high speed stirring pRoduces axial flow and local shear force.

$ 101.00

The blade width is 70mm, the blade height is 1.8mm, the Rod diaMeter is 6mm, and the Rod length is 300mm; stainless steel material, used at medium and high speed, pRoduces axial flow and local shear force, suitable for a variety of mixed needs.

$ 102.00

The stainless steel material ensures durability, the paddle width is 70mm, and the Rod length is 300mm. The design optimizes the mixing efficiency, and the medium and high speed operation pRoduces axial flow and local shear force, which is suitable for mixing various viscous liquids.

$ 98.00

The stainless steel material ensures durability, the blade width is 70mm, the height is 1.8mm, the Rod diaMeter is 8mm, and the length is 350mm. The medium and high speed operation pRoduces axial flow and local shear force, which is suitable for a variety of mixed needs.

$ 104.00

Articles

Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Application of Drop Hammer Impact Testing Machine in Evaluating Impact Resistance of Composite Materials
This article introduces how the drop-weight impact testing machine evaluates the impact resistance of composite materials. The test releases a weight to strike the specimen, measuring parameters such as energy absorption, peak load, and damage area, simulating low-velocity impacts like tool drops.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Surface Absorbency Tester for Predicting Drying Speed of Printing Ink on Coated Paper
This article explores how the surface absorbency tester predicts the drying speed of ink on coated paper. Traditional methods rely on actual printing tests, which are time-consuming and difficult to quantify.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.