Ion Multi-ParaMeter Detector

Ion multi-parameter detectors measure the concentrations of various ions in solutions, such as pH, sodium, and potassium, through electrodes. They are used in water quality monitoring and industrial process control to help obtain real-time data and ensure operations comply with standards.
Selection
When selecting an ion-selective multi-parameter detectors, considerations include the measurement parameter range, accuracy, electrode type, and calibration methods. It is essential to match the requirements of the application scenario, such as laboratory or field use, ensuring instrument stability and ease of maintenance.

Terms

Standards

Instruments

Built-in three measurement units can simultaneously detect pH, Conductivity Detector and dissolved oxygen, support automatic temperature compensation and ElectRode diagnosis, with IP54 Protection Rating, data storage capacity of 500 groups, support GLP specification to achieve data traceability.

$ 1142.00

High Accuracy Sensor for Multi-ParaMeter simultaneous measurement, Measurement speed up to 0.4 seconds, temperature error +/- 0.5 ℃, with backlight display and automatic shutdown function, portable design for on-site rapid detection.

$ 252.00

Measurement range up to 320μm, support Multi-ParaMeter such as Ra, Rz, etc., with automatic range switching and real-time waveform display function, Continuous Operating Time over 20 hours.

$ 835.00

Adopt DSP chip to realize fast data processing, support Multi-ParaMeter measurement such as Ra, Rz, etc., equipped with TYPE C and Bluetooth interface for data transmission, Continuous Operating Time exceeds 20 hours, and stores 100 sets of data.

$ 683.00

With pH/ORP/Temperature Multi-ParaMeter monitoring, Adjustable peristaltic pump Flow rate 0.5-3 L/h, Support automatic temperature compensation and dose consent function, Data recording interval of 10 seconds can be stored for 60 days.

$ 3015.00

Combined ElectRode can simultaneously measure pH, conductivity, TDS, salinity and temperature, support one-button switching paraMeters; Conductivity Detector ElectRode platinum black to reduce Polarization effect, accuracy of +/- 0.01pH; with automatic temperature compensation and IP67 dustproof and waterproof design.

$ 213.00

Support three-channel simultaneous measurement, equipped with 5.5-inch high definition touch screen, pH Measurement accuracy of +/- 0.002pH, with automatic temperature compensation and end point locking function, suitable for fast and accurate detection in a variety of environments.

$ 922.00

Equipped with 5.5 inch high definition touch screen, supports dual channel simultaneous measurement of 8 paraMeters, pH accuracy of +/- 0.002, with automatic temperature compensation and end point locking function, built-in GPS positioning and real-time data transmission.

$ 695.00

It can simultaneously measure pH, ORP, Ion concentration and other 9 paraMeters, equipped with Automatic calibration reminder and ElectRode diagnostic function, built-in 500 data storage capacity, support USB Communication interface to transmit data.

$ 909.00

Equipped with capacitive Touchscreen and color display, it supports five-point pH automatic identification calibrating and four-point EC calibrating. The data storage capacity reaches 100 groups, each group has 50,000 data points, and meets the USP- < 645 > conductivity analysis standard, which is especially suitable for pure water measurement applications.

$ 2552.00

Explosion-proof enclosure design ensures stable operation in harsh environments, can simultaneously monitor multiple particle size dust concentration without changing the cutter, Measurement range 0.01-100 mg/m ³, built-in protective gas curtain to prevent Optical inspection system contamination.

$ 5043.00

It can simultaneously read up to 8 water quality parameters, equipped with a 9000mAh large-capacity battery, supports Sensor address modification and temperature, zero point, slope calibrating, which is convenient for long-term operation and Facility Management on site.

$ 2526.00

It can simultaneously measure 16 water quality paraMeters, IP67 waterproof design, equipped with fluorescent DO Probe and automatic temperature compensation, data storage capacity of 45,000 pieces, support Bluetooth data transmission and GLP calibrated recording.

$ 5153.00

Integrate 8 water quality paraMeter measurement functions, support automatic temperature compensation and calibrated reminders, equipped with 500 sets of data storage capacity, and adopt multi-mode power supply scheme to ensure long-term outdoor use.

$ 909.00

With 5 measurement functions, support 1 to 5 point Conductivity Detector calibrating and automatic temperature compensation, can customize 13 paraMeters, equipped with 500 data storage and USB Communication interface, suitable for a variety of water quality paraMeters accurate measurement.

$ 667.00

Articles

Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Heating and blade coating of gel electrolyte films for zinc-ion batteries.
This article introduces the heating doctor-blade coating method for preparing gel electrolyte films in zinc-ion batteries. The method involves spreading a slurry onto a substrate using a doctor blade, followed by heating to evaporate the solvent and form a film.
Uniform coating of lithium-ion battery cathode slurry on aluminum foil.
This article primarily discusses how to uniformly coat the positive electrode slurry onto aluminum foil in lithium-ion battery manufacturing. The slurry itself exhibits shear-thinning properties, making it suitable for coating applications.
The film coater achieves controllable coating of lithium-ion battery anode slurry on copper foil.
This article explores how coating machines control the application process of the negative electrode slurry onto copper foil in the manufacturing of lithium-ion batteries.
The film coater is used for experimental-grade uniform coating of lithium-ion battery cathode slurry on aluminum foil.
This article explores the technique of uniformly coating lithium-ion battery cathode slurry on aluminum foil using a laboratory-grade coating machine.
Heating coating machine is used for the doctor-blade coating of gel electrolyte films in zinc-ion batteries.
This article introduces the blade coating process for preparing gel electrolyte films for zinc-ion batteries using a heated coating mechanism. By controlling parameters such as temperature, coating speed, and gap height, this method enables the fabrication of films with uniform thickness and smooth surfaces.
BET surface area analyzer evaluates the pore structure of ion exchange resins
This article introduces how to use a specific surface area analyzer to evaluate the pore structure of ion exchange resins.
Automatic Potentiometric Titration for Rapid Detection of Chloride Ion Content in Cement
This article introduces a method for rapidly detecting the chloride ion content in cement using an automatic potentiometric titrator. Excessive chloride ions can corrode steel reinforcement and affect the lifespan of concrete, making accurate detection crucial.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.