Glass Constant-Temperature Water Tank

The glass constant temperature water bath maintains a constant temperature of the liquid inside the tank through heating elements and temperature sensors. It is used for constant temperature processing of laboratory samples, temperature control of reactors, viscosity testing, and other applications.
Selection
When selecting, pay attention to the temperature range and fluctuation index, match the tank volume with the size of the experimental container, note the corrosion resistance of the material, ensure the flow rate of the circulation pump meets heat transfer requirements, and balance safety protection with ease of daily maintenance.

Terms

Standards

Instruments

Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.

$ 185.00

Temperature range -5~ 95 ℃, accuracy +/- 0.05 ℃, Tank volume 15L, pump flow 6L/min, providing uniform and constant temperature field source, suitable for a variety of test needs.

$ 1505.00

Temperature range -40~ 95 ℃, temperature accuracy +/- 0.1 ℃, Tank volume 15L, providing uniform and constant temperature field source, suitable for a variety of test needs.

$ 2936.00

Temperature range -10 ℃, Tank volume 10L, using fully enclosed Compressor unit and circulating water pump, energy saving and prevent scaling pollution of circulating water, protect the normal operation of the instrument.

$ 1379.00

Water Bath, water temperature box and boiling disinfection box three functions, Temperature range from room temperature to 100 ℃, Tank size 42 * 18 * 20cm, to meet a variety of experimental heating and disinfection needs.

$ 180.00

Using digital temperature control technology, Temperature range RT +~ 100 ℃, Tank size 300 * 300mm, combined design operation is more convenient, suitable for long-term stable operation.

$ 277.00

Temperature control range -10~ 95 ℃, accuracy up to +/- 0.05 ℃, equipped with 6L/min circulating pump to ensure uniform temperature, Tank volume 7.5L to meet the needs of multi-sample testing.

$ 1429.00

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

Temperature range -20~ 95 ℃, temperature accuracy +/- 0.05 ℃, Tank volume 15L, equipped with 6L/min circulating pump to ensure uniform and stable temperature, suitable for a variety of experimental needs.

$ 1726.00

Suitable for ultra-low conductivity water sample measurement, Glass grinder liquid interface design, pH Measurement range 0-11, Temperature range 0-80 ℃, support can add liquid reference solution.

$ 273.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, Temperature control accuracy 0.01 ℃, Built-in High Accuracy PT100 Sensor, support external circulation and domestic circulation system, ensure that the flow field and temperature field in the Tank are highly uniform.

$ 869.00

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

Temperature range -40~ 95 ℃, temperature control accuracy +/- 0.1 ℃, Tank volume 7.5L, circulating pump flow 6L/min, providing a uniform and constant temperature environment.

$ 2089.00

Temperature range -20 ℃, Tank volume 10L, using fully enclosed Compressor unit and circulating water pump, energy saving and anti-scaling, protect precision instruments in high temperature environment stable operation.

$ 1900.00

Temperature range -50~ 100 ℃, accuracy +/- 0.02 ℃, equipped with imported Compressor and circulating pump, support multi-stage programming and data processing interface, with over-temperature alarm and liquid level protection function.

$ 3335.00

Articles

Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
DSC analyzer measures the glass transition of degradable films.
This article explains how to use a differential scanning calorimeter to measure the glass transition temperature of a degradable film. It first clarifies that the glass transition is the process by which a material changes from a glassy state to a highly elastic state, which appears as a baseline shift on the curve.
The film coater applies a conductive film onto transparent substrate test pieces.
This article introduces a method for uniformly coating conductive films on transparent substrates such as glass or plastic films using a film applicator.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
The polymer film is formed by blade coating on a glass substrate using a film applicator.
This article introduces the technique of using a film applicator to doctor-blade polymer films onto glass substrates.
Differential scanning calorimetry for determining the glass transition temperature of epoxy resin
Differential scanning calorimetry analyzes the thermal properties of materials by measuring the heat flow difference between the sample and a reference material.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Differential Scanning Calorimetry for Determining the Melting Point and Glass Transition Temperature of Hot Melt Adhesives
This article introduces the method of determining the melting point and glass transition temperature of hot-melt adhesives using a differential scanning calorimeter. Differential scanning calorimetry analyzes the thermal transition characteristics of materials by measuring the energy difference between the sample and a reference material.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.