Conductivity Salinity Temperature Controller

The conductivity salinity temperature controller measures the electrical conductivity of a solution via electrodes to calculate salinity, and compensates the readings with a temperature sensor. It is used to monitor water quality, industrial processes, and aquaculture environments, ensuring stable solution parameters.
Selection
When selecting, consider the measurement range matching the sample characteristics, check the temperature compensation accuracy, confirm the electrode material's corrosion resistance, inspect the ease of calibration, and evaluate the output interface compatibility with existing equipment.

Terms

Standards

Instruments

Simultaneous measurement of conductivity, resistivity, TDS, salinity and temperature, support automatic temperature compensation and ElectRode diagnosis, Data storage 450 groups, with IP54 dustproof and waterproof rating, Measurement accuracy up to +/- 1.0% FS.

$ 514.00

Support conductivity, TDS, salinity and resistivity Multi-ParaMeter measurement, conductivity range 0.000 μS/cm to 1000mS/cm, with intelligent end point determination and automatic temperature compensation function.

$ 741.00

With conductivity, TDS, salinity, resistivity four measurement functions, Measurement accuracy of 0.5% F. S, support 1 to 5 point calibrating and automatic temperature compensation, built-in 500 data storage and USB Communication interface to ensure full range accurate measurement.

$ 435.00

Equipped with 7-inch TFT display, support conductivity, TDS, salinity and other 5 paraMeter measurement, Measurement accuracy of 0.5% F.S, with 1000 data storage and automatic temperature compensation function.

$ 677.00

Supports dual paraMeter measurement of conductivity salinity, Measurement accuracy up to 0.5% F. S, with automatic temperature compensation and ElectRode diagnostic functions, can store 500 sets of data and comply with GLP specifications.

$ 323.00

Combined ElectRode can simultaneously measure pH, conductivity, TDS, salinity and temperature, support one-button switching paraMeters; Conductivity Detector ElectRode platinum black to reduce Polarization effect, accuracy of +/- 0.01pH; with automatic temperature compensation and IP67 dustproof and waterproof design.

$ 213.00

Measurement accuracy of 0.5% and automatic temperature compensation, 1 to 5 point calibrated and 500 data storage, ElectRode constant selection and salinity Measurement mode.

$ 435.00

Equipped with 7-inch TFT display, support conductivity, TDS, salinity, resistivity and Conductivity Detector ash 5 kinds of paraMeter measurement, Measurement accuracy of 0.5% F.S, automatic temperature compensation and 1000 groups Data storage function.

$ 593.00

Measurement accuracy 0.5% F.S., Conductivity Detector pool constant K = 0.1/1/10 optional, built-in 500 data storage and automatic temperature compensation to ensure accurate measurement of full scale.

$ 546.00

Platinum ElectRode ensures fast and stable measurement, supports 1-3 point calibrating and automatic temperature compensation, salinity Measurement range 0-80ppt, conductivity covers 100μS/cm to 200mS/cm, with automatic end lock and fully waterproof design.

$ 167.00

Platinum Sensor ensures fast and stable measurement, supports 1-3 point calibrate and 0.1-1 adjustable TDS conversion factor, with automatic temperature compensation and end point locking function, Measurement range covers 0-20mS/cm conductivity and 0-10ppt salinity.

$ 165.00

With 7-inch TFT display and 1000 data storage, it supports Multi-ParaMeter measurement such as conductivity, TDS, salinity, etc., with an accuracy of 0.5% F.S., automatic temperature compensation and calibrated reminder function to ensure measurement Reliability.

$ 566.00

With conductivity 0~ 19.99mS/cm Measurement range, accuracy +/- 1.0%, support TDS conversion factor and temperature compensation settings. Platinum-plated black ElectRode reduces Polarization effect, IP67 Protection Rating is suitable for use in a variety of environments.

$ 155.00

With 5 measurement functions, support 1 to 5 point Conductivity Detector calibrating and automatic temperature compensation, can customize 13 paraMeters, equipped with 500 data storage and USB Communication interface, suitable for a variety of water quality paraMeters accurate measurement.

$ 667.00

Equipped with 3.5-inch TFT color screen and navigation operation, supports conductivity 0~ 2000.0mS/cm automatic segmented measurement, with ElectRode constant optional, manual automatic temperature compensation and 3000 groups of Data storage, using Type-C charging and IP57 protection design.

$ 507.00

Articles

Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.