Ammonium Ion Analysis System

The ammonia ion analyzer detects the concentration of ammonium ions in water samples using an ion-selective electrode. The electrode forms a potential difference with a reference electrode, and the potential value has a linear relationship with the logarithm of the ammonia ion concentration. It is used to monitor ammonia nitrogen content in wastewater, soil, and food, and finds applications in environmental monitoring and water quality control.
Selection
When selecting an ammonia ion analyzer, consider whether the detection range matches the sample concentration, electrode lifespan and replacement costs, ease of operation of the interface, data storage and output functions, anti-interference capability for handling complex samples, calibration cycles and maintenance requirements, and instrument portability based on usage scenarios.

Terms

Standards

Instruments

250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.

$ 127.00

Optimized for Ammonium Ion Composite ElectRode, 250ml Encasement meets the needs of routine use, improves ElectRode Response performance by adjusting the ionic strength, and is suitable for a variety of detection environments.

$ 127.00

Designed for ammonium ion detection, providing a stable reference potential, 250ml Encasement meets the needs of long-term use and ensures the accuracy of ion-selective ElectRode measurement.

$ 99.00

Measurement accuracy of 0.5% F.S. with 5 point button calibrating and automatic end point locking technology, support for a variety of Ion concentration Unit switches, built-in 500 data storage and automatic temperature compensation functions.

$ 696.00

Using composite ElectRode design, equipped with special reference filling solution and calibrating solution, Measurement accuracy is high, BNC interface compatibility is strong, suitable for a variety of water quality analysis scenarios.

$ 309.00

Measurement accuracy of 0.5% and automatic temperature compensation, 2 to 5 point calibrated and 500 data storage, backlit display and USB interface for outdoor use.

$ 696.00

Designed for Fluoride Ion Composite ElectRode, 250ml standard Encasement is provided to ensure stable ElectRode performance and reliable measurement data, suitable for a variety of ion analysis scenarios.

$ 110.00

Specially designed for sodium ion detection, 250ml standard Encasement, ElectRode measurement accuracy is ensured by adjusting the ionic strength of the solution, suitable for a variety of water quality analysis scenarios.

$ 127.00

Constant background ion strength, Shielding interfering ions and adjusting sample pH value, capacity 480mL, PTFE bottle Encasement, suitable for a variety of ion measurement environment.

$ 135.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 1% F. S, suitable for a variety of Ion concentration detection.

$ 864.00

Dedicated to lead ion detection system, 250ml standard Encasement, ElectRode potential stability is ensured by adjusting ion strength, and measurement accuracy and Repeatability are improved.

$ 127.00

Using BNC connector design, equipped with 60mL reference filling solution and calibrated solution, provides stable potassium ion selective detection, suitable for laboratory water quality analysis.

$ 309.00

Calcium Ion concentration 1000ppm, PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating, to ensure measurement accuracy.

$ 135.00

With 1% F. S Measurement accuracy and automatic temperature compensation function, it supports 500 sets of Data storage and a variety of Ion concentration unit selection, equipped with large screen backlight display and automatic ElectRode diagnostic system.

$ 696.00

Measurement range of 1~ 2 × 10, using BNC plug design, matching pH and ion Meter, easy operation and fast Response, suitable for accurate Ion concentration detection.

$ 191.00

Articles

Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Heating and blade coating of gel electrolyte films for zinc-ion batteries.
This article introduces the heating doctor-blade coating method for preparing gel electrolyte films in zinc-ion batteries. The method involves spreading a slurry onto a substrate using a doctor blade, followed by heating to evaporate the solvent and form a film.
Uniform coating of lithium-ion battery cathode slurry on aluminum foil.
This article primarily discusses how to uniformly coat the positive electrode slurry onto aluminum foil in lithium-ion battery manufacturing. The slurry itself exhibits shear-thinning properties, making it suitable for coating applications.
The film coater achieves controllable coating of lithium-ion battery anode slurry on copper foil.
This article explores how coating machines control the application process of the negative electrode slurry onto copper foil in the manufacturing of lithium-ion batteries.
The film coater is used for experimental-grade uniform coating of lithium-ion battery cathode slurry on aluminum foil.
This article explores the technique of uniformly coating lithium-ion battery cathode slurry on aluminum foil using a laboratory-grade coating machine.
Heating coating machine is used for the doctor-blade coating of gel electrolyte films in zinc-ion batteries.
This article introduces the blade coating process for preparing gel electrolyte films for zinc-ion batteries using a heated coating mechanism. By controlling parameters such as temperature, coating speed, and gap height, this method enables the fabrication of films with uniform thickness and smooth surfaces.
BET surface area analyzer evaluates the pore structure of ion exchange resins
This article introduces how to use a specific surface area analyzer to evaluate the pore structure of ion exchange resins.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Automatic Potentiometric Titration for Rapid Detection of Chloride Ion Content in Cement
This article introduces a method for rapidly detecting the chloride ion content in cement using an automatic potentiometric titrator. Excessive chloride ions can corrode steel reinforcement and affect the lifespan of concrete, making accurate detection crucial.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Effect of Platform Temperature on Surface Drying Time of Waterborne Polyurethane Coatings in Heated Automatic Film Applicators
This study investigates the influence of the platform temperature of a heated automatic film applicator on the surface drying time of waterborne polyurethane coatings. The experiments reveal that as the platform temperature increases, the surface drying time of the coating significantly decreases, showing a negative correlation between the two.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.