Temperature range -20~ 150 ℃, Temperature Uniformity ≤ +/- 2.0 ℃, using multi-layer conductive film tempered hollow Glass observation window and upper air supply and lower air return mode to ensure stable and reliable test environment.
Temperature range -40~ 150 ℃, Temperature Uniformity ≤ +/- 2.0 ℃, using multi-layer conductive film tempered hollow Glass observation window and upper air supply and lower air return mode to ensure stable and reliable test environment.
Temperature range -70~ 150 ℃, Temperature Uniformity +/- 2 ℃, using multi-layer conductive film observation window and upper air supply and lower air return system, support 120 sets of program settings and continuous PID control, with multiple safety protection mechanisms.
Temperature range -30~ 150 ℃, equipped with multi-layer conductive film tempered hollow Glass observation window and upper air supply and lower air return system, using porcelain frame nickel-chrome wire electric heating device and French Taikang fully enclosed Compressor to ensure Temperature Uniformity ≤ +/- 2.0 ℃.
Temperature range -30~ 150 ℃, studio volume 800L, multi-layer conductive film observation window and independent over-temperature protector, with 120 sets of program settings and continuous PID control function.
Temperature range -30~ 150 ℃, studio volume 500L, using multi-layer conductive film observation window and PID continuous control, with 120 sets of program settings and multiple safety protection systems to ensure stable and reliable testing.
Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.
Temperature range -20~ 150 ℃, Temperature Uniformity ≤ +/- 2 ℃, using PID control and multi-layer observation window design, with 120 sets of program settings and over-temperature protection functions, suitable for component stress screening.
Temperature range -30~ 150 ℃, Temperature Uniformity ≤ +/- 2 ℃, using PID continuous control mode, with 120 sets of program settings and multiple safety protection systems, suitable for temperature gradual change test and stress screening.
Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.
Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high and low temperature cycle change test, suitable for material performance inspection and aging test, equipped with multiple safety protection devices.
Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and aging test, in line with a number of national standards.
Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.
Temperature range -40~ 150 ℃, Temperature Uniformity +/- 2 ℃, using the upper air supply and lower return air mode to ensure uniform temperature, with multi-layer conductive film observation window and independent over-temperature protection system, support 0~ 999 hours timing function.
Temperature range -60~ 150 ℃, studio volume 150L, using the upper air supply and lower air return mode and multi-layer conductive film tempered hollow Glass observation window, equipped with independent over-temperature protector and a variety of Safety protection measures.