Dual-chamber temperature shock test chamber

The two-zone thermal shock test chamber rapidly switches between the high-temperature chamber and the low-temperature chamber, enabling instantaneous transition of samples between extreme temperatures. Its principle involves utilizing independent temperature zones and a sample transfer mechanism to simulate environments with sudden temperature changes. Its purpose is to test the thermal expansion and contraction properties of materials as well as structural stability. It is applied in validating the temperature resistance performance of products such as electronic components, coatings, and plastic products.
Selection
When selecting a two-zone thermal shock test chamber, it is essential to consider that the temperature range should cover the testing requirements, with the transition time typically chosen to be within 5 seconds. The sample area dimensions must match the volume of the test objects. Attention should be paid to the corrosion resistance of the inner chamber material, and the control system should include temperature calibration and fault recording functions. Confirm the temperature recovery time and uniformity parameters according to the testing standards, and select the appropriate power based on the actual load.

Terms

Standards

Instruments

The two-box mobile structure is adopted, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. It is equipped with HFC environmentally friendly refrigerant and binary ultra-low temperature freezing system, which has high cooling speed and efficiency. It supports paperless recording and real-time Linear dispersion display function.

$ 16840.00

The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.

$ 21858.00

Using two-box mobile Impact structure, Thermal Shock mechanism moves within 10 seconds, temperature recovery time ≤ 5 minutes, equipped with rigid polyurethane foam insulation material, effective energy saving and waterproof and moisture proof.

$ 23682.00

Adopt two-box mobile structure, air pressure drive test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL and other international test standards.

$ 19809.00

Using three-box equipment structure, the temperature conversion time does not exceed 10 seconds, the temperature control accuracy reaches +/- 0.5 ℃, and the air circuit switching method realizes fast Thermal Shock, which is suitable for material physical and chemical change testing.

$ 38156.00

With three-box structure design, the temperature conversion time is only 10 seconds, the temperature control accuracy is up to +/- 0.5 ℃, and it is equipped with touch graphic operation interface and air passage switching system to achieve fast and stable Thermal Shock testing.

$ 36381.00

The three-box structure design is adopted, the temperature conversion time does not exceed 10 seconds, the temperature control accuracy is up to +/- 0.5 ℃, the Thermal Shock test is realized through the air circuit switching, and the touch graphic operation interface is equipped to simplify the operation process.

$ 16759.00

The use of PWM cold control technology implementation of low temperature energy-saving operation, can reduce 40% energy consumption; equipped with programmable color screen controller, the experiment cycle, 5 days defrost only 2 hours.

$ 15403.00

Adopting a three-box structure design, the temperature recovery time does not exceed 5 minutes, and the temperature conversion is completed within 10 seconds. It is equipped with a touch-sensitive graphic operation interface and an air path switching system to achieve fast and stable Thermal Shock testing.

$ 12660.00

Two-box mobile structure, air pressure driven test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL, IEC and other specifications, with paperless recording and real-time Linear dispersion display function.

$ 17985.00

Using a two-box mobile Impact structure, the air pressure drives the test object to move up and down, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. Equipped with HFC environmentally friendly refrigerant and ultra-low temperature freezing system, the cooling is fast and efficient.

$ 16840.00

Temperature range from -40 ° C to + 150 ° C, supports 120 program edits. Dual Compressor design, Temperature Fluctuation +/- 0.5 ° C, data collection and remote monitoring.

$ 11982.00

With three-box structure design, the temperature conversion time is only 10 seconds, the temperature control accuracy is up to +/- 0.5 ℃, and it is equipped with touch graphic operation interface and dual Compressor chill down system to ensure stable and efficient testing.

$ 55261.00

With automatic dual range dual accuracy function, support 0.01g Minimum Weight, adjustable six-level shock filter, built-in temperature display and a variety of unit conversion, suitable for High Accuracy weighing requirements in complex environments.

$ 441.00

With automatic dual range dual accuracy function, support 0.01g accuracy and six-level shock filter, provide a variety of unit conversion and weighing mode, built-in temperature display and Stabilization time adjustable.

$ 377.00