Spot ThermoMeter

The point thermometer receives the infrared energy radiated from the surface of an object through an infrared sensor and converts it into a temperature reading. It is used to measure the temperature at a specific point on the surface of an object, such as monitoring the operating temperature of equipment or detecting the drying process of materials in industrial applications.
Selection
When selecting a point thermometer, it is important to consider that the measurement temperature range matches the target object, the response time meets on-site requirements, the measurement distance and spot size align with the actual application scenario, the impact of environmental conditions such as dust or steam, as well as the device's protection rating and calibration requirements.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Standards

Instruments

With 60 ° Measurement Angles and 2 * 2mm small light spot, suitable for surface and small area object measurement; LED long life Illuminant and quartz crystal standard version, the annual change rate is extremely low; a battery can be used continuously for nearly 60 hours.

$ 587.00

With 60 ° Measurement Angles and 36x18mm light spot size, the range is 0-199.9GU, and the built-in rechargeable battery can work for 48 hours to meet the needs of surface Gloss measurement of various materials.

$ 344.00

Adopting ceramic roller synchronous inking technology, the pressure can be adjusted by +/- 2mm, and the material proofing with a thickness of 0.01~ 2mm is supported to achieve accurate repRoduction of solid color and Dot patterns.

$ 8949.00

Pressure adjustable range -1 to + 1mm, proofing speed support 400-700rpm three-speed frequency conversion speed regulation, uniform ink time 15-800 seconds adjustable, fixed structure to ensure proofing Stability.

$ 4592.00

Precise control of ink layer thickness, the minimum Basis Weight unit is 0.01CC, and the usage of Spot Color inks is predicted by calculation, which is suitable for ink contrast and color concentration detection.

$ 332.00

The pressure of 0-700N can be adjusted to adapt to different substrates, the separate transfer system is easy to clean and maintain, supports the calculation function of inks transfer rate, and uses the middle ink extraction method to improve the lateral uniformity.

$ 6528.00

Equipped with High Accuracy Servo Motor, uniform ink speed adjustable 0-300rpm, pressure 0 to 1kpa pneumatic adjustment, using circular embossing method to improve fit, support quick replacement of anilox roller.

$ 7049.00

Adopt circular embossing method to improve the fit, the proofing speed is adjustable from 0-300rpm, equipped with High Accuracy Servo Motor and quick replacement anilox roller system, support a variety of gray scale customization.

$ 7335.00

With penetrating AISI 316 stainless steel Probe, easy to clean and insert semi-solid pRoducts. With CAL Check ™ boot self-check function, temperature accuracy of +/- 0.2 ℃, Measurement range covering -50.0~ 220 ℃.

$ 211.00

The multi-stage color development structure can simultaneously print 4 color strips of different thicknesses or Hue, and the uniform ink speed can be adjusted by 500-800rpm in three gears. With the Basis Weight instrument, the ink layer thickness is precisely controlled, and the operation is simple and durable.

$ 5237.00

Adjustable pressure 0~ 2mm, support three uniform ink speed 650-1000rpm and printing speed 10-20rpm, automatic uniform ink function to ensure stable operation, suitable for different thicknesses of paper and plastic film proofing comparison.

$ 3462.00

Foldable stainless steel probe design, temperature range -49.9~ 49.9 ℃, Accuracy up to +/- 0.5 ℃, equipped with large LCD display and Fahrenheit switching function, easy to high temperature liquid safety measurement.

$ 318.00

Temperature range from -50.0 to 1350 ℃, support dual-line display real-time and maximum MIN Minimum, equipped with automatic shutdown and HOLD locking function, resolution of 0.1 ℃/1 ℃, adapt to a variety of environmental conditions.

$ 332.00

With CAL Check ™ boot Self-check function, temperature measurement accuracy of +/- 0.2 ℃, using penetrating AISI 316 stainless steel Probe, IP65 waterproof, suitable for semi-solid and frozen material temperature measurement.

$ 199.00

With -50~ 900 ℃ wide range and +/- 2% accuracy, 12:1 object distance ratio for non-contact measurement, Response Time 500ms, compact and lightweight only 170g, suitable for high temperature or hazardous environment.

$ 114.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Vicat softening point tester measures the heat deflection temperature of special engineering plastics.
The Vicat softening point tester measures the temperature at which a needle penetrates a plastic sample to a specified depth by heating and applying a load, thereby evaluating the heat deflection temperature of special engineering plastics.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Sealing Tester Measures Leak Points in Flexible Packaging Bags.
This article introduces how a seal tester detects air leak points in flexible packaging bags. It primarily identifies leaks through changes in pressure or vacuum, and the operation involves preparing samples, setting parameters, and conducting standardized testing.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Flash Point Tester Selection: Applicable Scenarios for Closed Cup and Open Cup Methods
This article introduces the differences between the closed-cup method and the open-cup method in flash point testing.