Sulfur Hexafluoride Gas Alarm

The sulfur hexafluoride gas alarm detects the concentration of SF6 in the environment through electrochemical or infrared sensors and triggers audible and visual alarms when gas leakage exceeds the set threshold. It is used in places such as electrical equipment rooms and laboratories to monitor the leakage of insulating gases, preventing equipment failures and safety hazards.
Selection
When selecting, consider the detection range covering the equipment's operating concentration, confirm the sensor lifespan and calibration cycle, check the protection rating to suit the installation environment, evaluate the alarm recording function, compare response time and false alarm rate, and ensure compliance with local safety standards.

Terms

Standards

Instruments

Measurement principle of cold mirror to eliminate system inertia error, accuracy of +/- 0.2 ° C, built-in electronic flowMeter to monitor 15-60L/h gas flow, system stability without repeability calibration.

$ 14371.00

Using Infrared NDIR Detection Principle, Range 0-100ppm, Response Time ≤ 30S, Flameproof Structure and Various Signal Outputs, Support Remote Monitoring and Intelligent Sensor Technology, Ensure High Accuracy and Stability.

$ 590.00

Using Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, shell explosion-proof structure, 4-20mA standard signal output, can detect a variety of gas concentrations and have sound and light alarm function.

$ 267.00

Support simultaneous detection of 4 kinds of gases, integrated temperature Humidity detection function, physical + software double revisit Humidity compensation, Response Time T90 ≤ national standard, detection accuracy ≤ +/- 3% FS, with a variety of alarm and remote monitoring capabilities.

$ 658.00

8Mm thick PVC reinforced rigid plastic plate box, sulfur dioxide concentration adjustment range of 600~ 10000ppm, equipped with corrosion-resistant silicone airway and alkali solution exhaust gas treatment system, temperature control accuracy +/- 0.5 ℃.

$ 15823.00

Using electrochemistry principle to detect 0-100ppm sulfur dioxide, with 4G/WIFI wireless communication, IP66 Protection Rating, four Alarm modes and 12-55 hours battery life, support remote paraMeter configuration and temperature compensation algorithm.

$ 588.00

Designed with flameproof and explosion-proof structure, Response Time is less than 30 seconds, accuracy +/- 3% FS, can detect 0-20ppm sulfur dioxide concentration, support 4-20mA and RS485 signal output, suitable for harsh industrial environments.

$ 251.00

Support 4 kinds of gas simultaneous detection, integrated temperature Humidity monitoring, physical + software double revisit Humidity compensation, with zero automatic correction function, Response Time T90 ≤ national standard, detection accuracy ≤ +/- 3% FS.

$ 1050.00

Supports 4-20mA signal input, compatible with two-wire and three-wire devices, provides 6 passive switches and RS485 interfaces, with two-level alarm settings, operating temperature 0-40 ℃, suitable for gas safety detection.

$ 212.00

Support 16 4-20mA signal input, 4.3 inch color screen display, can store 20000 alarm records, with two-level alarm and four sets of relay output, suitable for multi-point centralized control of Gas detection.

$ 259.00

Support 4-20mA/RS485 signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching quantities, two-level alarm can be freely set, suitable for gas safety detection.

$ 259.00

Support 4-20mA signal input and RS485 upload, with 2-level alarm and 2 relay output, compatible with two-wire and three-wire equipment, fast response speed and high measurement accuracy, suitable for a variety of Gas detection scenarios.

$ 140.00

Electrochemical sensor, sulfur dioxide detection range 0-20ppm, resolution 0.1ppm, with IP65 Protection Rating and 12864 point matrix display, support sound, light, vibration triple Alarm mode.

$ 235.00

Support 4-20mA signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching and sound and light alarm functions, operating temperature 0-40 ℃, suitable for a variety of Gas detection scenarios.

$ 183.00

Explosion-proof structure design, Response Time is less than 30 seconds, with 4-20mA standard signal output, can detect a variety of gas concentrations and set high and low alarm points to ensure industrial environment safety monitoring.

$ 267.00