Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the accuracy of light transmitance and haze display is 0.01%, equipped with thin film magnetic fixture and liquid sample Cup, and supports 2000 sets of data storage.
Based on the principle of flow between parallel plates, it can quickly and accurately measure inks spread under low shear stress. The sample volume is 0.5 +/- 0.003 cubic centiMeters, and the maximum measurement range of the plate is 9cm. It is suitable for inks flowability evaluation.
Parallel light path design can measure 100mm thickness material, accuracy +/- 1%, resolution of 0.001%, support field and fixed station two Measurement mode, suitable for a variety of Optical inspection material detection.
Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the light transmitter and haze measurement accuracy are 0.01%, support U disk storage and USB communication, equipped with thin film magnetic fixture and liquid sample Cup.
Imported linear slide rail to ensure parallel accuracy 0.1 +/- 0.01mm, blade Hardness can be cut steel, sampling thickness 0~ 5mm, special treatment die durable and easy to restore accuracy.
Using parallel illumination hemisphere scattering integrating sphere photoelectric reception mode, light transmitance measurement range 0-100%, haze measurement range 0-99%, with open sample window design, not affected by environment light.
Adopt three-in-one parallel light path design, one measurement of visible light, infrared and ultraviolet transmittance; test aperture 1.3mm, suitable for small size and thick materials; Automatic calibration and large capacity storage function.
Measurement accuracy +/- 2%, equipped with 5 calibrated oils to ensure measurement accuracy, as a special accessory for cone-plate viscoMeter to achieve stability testing.
The shear rate is 2.0N, only 0.5ml sample volume can be completed to complete the test, suitable for a variety of models of Viscometer host, to meet the measurement needs of different viscosity ranges.
The device places the test plate in parallel in the wind tunnel, the wind speed control accuracy is 3 +/- 0.3m/s, the drying time is automatically controlled, and the surface crazing can be visually inspected, which is suitable for the evaluation of coating anti-crack performance.
Range 5-50p, accuracy of +/- 2%, equipped with 5 kinds of special calibrated oil to ensure measurement accuracy, as the core component of cone-plate viscoMeter to ensure test Stability.
Measurement modes: Rotor speed 562rpm, accuracy of +/- 1% F.S. Microprocessor control ensures measurement accuracy and Repeatability, quick release chuck for cleaning and maintenance.
The device provides 3 +/- 0.3m/s wind speed through axial flow fan in wind tunnel, Timer delay range of 0.01 seconds to 99 hours 99 minutes, can automatically control drying time and eye test plate surface crazing, support parallel test.
Shear rate 3.84N, sample size only 0.5ml, suitable for a variety of Viscometer models, ensuring High Accuracy measurement and wide applicability.
Adopt helical tooth bar/helical gear lifting system, add universal joint at connecting rotor, variable gear is high wear-resistant engineering plastic, viscosity range 1~ 2000000mPa.s, Measurement accuracy +/- 5% F.S.