Small Low-Temperature Thermostatic Circulating Bath

The small low-temperature constant temperature circulation bath cools down through a compressor or thermoelectric refrigeration system, and works in conjunction with a circulation pump to maintain the liquid inside the bath at the set low temperature. It is used in scenarios such as laboratory sample cooling, reactor temperature control, and low-temperature testing of materials, ensuring that the temperature remains stable within the sub-zero range.
Selection
When selecting, consider the temperature range covering experimental needs, match the cooling power to the required cooling rate, ensure the tank size is compatible with the container dimensions, pay attention to temperature fluctuation accuracy and pump flow parameters, check safety protection features such as liquid level alarms, and choose between air-cooled or water-cooled heat dissipation methods based on the usage environment.

Terms

Standards

Instruments

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

The double Compressor and cascade refrigeration system are used to cool down quickly and have low noise; the overall foaming insulation of the Tank body reduces the loss of cooling capacity, the flow rate of the circulating pump is 10L/min to ensure Temperature uniformity, and the Temperature Fluctuation is only +/- 0.05 ℃.

$ 1653.00

Imported PT100 temperature sensor and double Compressor cascade refrigeration system, high refrigeration efficiency and low noise, Temperature Fluctuation +/- 0.05 ℃, Tank volume 30L, Circulating pump Flow rate 10L/min to ensure Temperature uniformity.

$ 3656.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices including low water level protection and temperature runaway alarm functions.

$ 6347.00

Temperature range -30~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming Tank body to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.

$ 1293.00

Microcomputer temperature control self-tuning PID adjustment technology, temperature control accuracy of +/- 0.05 ℃, Temperature Fluctuation is small; with internal and external circulation function, pump Flow rate 10L/min, support external system thermostatic control; fully enclosed Compressor refrigeration, low noise efficiency.

$ 4064.00

Imported Pt100 temperature sensor, Temperature range -30~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, double Compressor cascade refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.

$ 2575.00

Temperature range -20~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system is used for rapid cooling, the overall foaming and heat insulation of the Tank body reduces the loss of cooling capacity, and circulating stirring ensures Temperature uniformity.

$ 1653.00

The non-heat centrifugal circulating pump is used to ensure uniform insulation field, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices such as low water level anti-dry burning and Compressor overcurrent protection, optional temperature control and external Sensor to enhance application flexibility.

$ 4482.00

Adopt non-heat centrifugal circulating pump to avoid self-heating effect, Temperature Uniformity +/- 0.05 ℃, equipped with multiple Safety protection including low water level anti-dry burning and Compressor over-current protection to ensure the safety and stability of the experiment.

$ 803.00

Temperature range -40~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.

$ 3155.00

The double Compressor refrigeration system is adopted to ensure rapid cooling, the overall foaming and heat insulation of the Tank body reduces the loss of cooling capacity, the flow rate of the circulating pump is 8L/min to ensure the uniformity of the liquid, and the Temperature Fluctuation is only +/- 0.05 ℃.

$ 1492.00

Temperature range -50~ 100 ℃, temperature resolution of 0.01 ℃, fully enclosed Compressor refrigeration and 304 stainless steel liner, equipped with 10L/min circulating pump and removable side panels for easy cleaning and maintenance.

$ 5931.00

Imported Pt100 temperature sensor and dual Compressor refrigeration system, rapid cooling and low noise, Temperature Fluctuation +/- 0.05 ℃, 6L volume Tank with 8L/min circulating pump to ensure Temperature uniformity.

$ 971.00

Temperature range -20~ 100 ℃, temperature resolution 0.1 ℃, fully enclosed Compressor refrigeration and 304 stainless steel liner, equipped with high-performance circulating pump and multiple safety protection devices to ensure stable operation.

$ 1558.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.