Portable Ammonia Nitrogen Water Quality Detector

The portable ammonia nitrogen water quality detector adopts the Nessler's reagent spectrophotometric method. Ammonia nitrogen in the water sample reacts with the reagent to form a yellow-brown complex, and the ammonia nitrogen concentration is calculated by measuring the absorbance. It is used for rapid on-site detection of ammonia nitrogen content in water bodies and is suitable for fields such as wastewater treatment, aquaculture, and environmental monitoring.
Selection
When selecting, ensure the detection range covers actual needs and the precision meets usage standards. Check whether the instrument features automatic temperature compensation and calibration functions. Confirm reagent storage conditions and shelf life. Consider the instrument's protection rating to suit the usage environment, and note that the simplicity of the operation interface affects detection efficiency. Compare the cost and supply stability of consumables across different brands.

Terms

Standards

Instruments

Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.

$ 164.00

Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.

$ 209.00

Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.

$ 1806.00

Colorimetric digestion integrated tube operation, no liquid transfer; water samples for more than 10 measurements to take the average value; ammonia nitrogen detection limit of 0.01mg/L, measurement error ≤ +/- 5%, data storage 30,000.

$ 1493.00

Optical inspection system using imported cold Illuminant and narrow band interference, Optical inspection stability is less than 0.002A/20min, digestion temperature accuracy +/- 0.5 ℃, support COD and ammonia nitrogen dual paraMeter measurement, can save multiple standard Linear dispersion and data.

$ 1548.00

It can simultaneously detect 9 paraMeters such as residual chlorine, chlorine dioxide, ammonia nitrogen, etc., with a resolution of 0.001mg/L. It adopts high-intensity long-life Illuminant and micro-processing technology to ensure long-term stable operation.

$ 877.00

Measurement range 0.00~ 9.99 ppm, accuracy +/- 0.05 ppm, LED Illuminant 470 nm, automatic shutdown function, compact and portable design.

$ 217.00

With 12 water quality paraMeter detection capabilities, resolution of 0.001mg/L, Repeatability 2%, micro-processing technology and long-life Illuminant, support custom Linear dispersion calibrating and data smoothing.

$ 1058.00

Optical inspection Colorimetric detection principle, eliminate human error, measurement resolution of 0.1mg/L, Repeatability ≤ 2%, suitable for indoor and outdoor water quality testing environment.

$ 240.00

Colorimetric measurement based on Nasler method, Measurement range 0.00-10 mg/L, providing 100 tests, accurate determination of ammonia nitrogen concentration by Color intensity change.

$ 212.00

Microprocessing technology and Reliability IC, with 0.001mg/L resolution and +/- 5% FS Indication Error, support custom Linear dispersion calibrating and data smoothing functions to ensure long-term stable operation.

$ 356.00

The imported cold light source has a lifespan of 100,000 hours, a detection limit of 0.05mg/L, supports continuous measurement and standard Measurement mode, and has 4000 sets of data storage and various transmission interfaces.

$ 816.00

Adopting digestion Colorimetric integrated tube design, the detection process is safer and more convenient; the minimum display value is 0.001mg/L, and the Sensitivity is high; it supports a variety of detection paraMeter expansion to meet different water quality testing needs.

$ 4688.00

Measurement range 0.02~ 25mg/L, resolution 0.01mg/L, Repeatability ≤ 3%, Linearity +/- 3% FS, eliminating human error.

$ 262.00

Digestion instrument and measuring instrument separation design to ensure measurement accuracy, using PID automatic temperature control technology, temperature range to 180 ℃, temperature control accuracy +/- 0.5 ℃, support 4 water sample batch processing, Optical inspection stability is better than 0.002A/20min.

$ 1753.00

Articles