Built-in Air Temperature Humidity Sensor and K-Connector, with armored cable and magnetic surface temperature sensor to prevent accidental detachment, supports a variety of optional Probe conversions.
With split Probe design, Temperature Measurement range covering -10~ 50 ℃, can be extended to 1000 ℃, Humidity Measurement range 5~ 98% RH, error +/- 1.5 ℃ and +/- 5%, support unit conversion, portable and durable.
Humidity controller with dry and wet bulb type or electric kiln type, temperature fluctuation +/- 0.5 ℃, humidity deviation +/- 3% RH; with independent temperature limit alarm, Compressor multiple protection and water shortage protection functions to ensure safe operation.
The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.
Simultaneous measurement environment Humidity and surface temperature, accuracy of +/- 0.5 ℃, storage of 20000 readings, support for a variety of K-type Probe extended measurement, with real-time graphics display and wireless transmission function.
Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.
Equipped with fixed K-type stainless steel penetration Probe, Response Time 20 seconds, IP65 waterproof standard, with CAL Check ™ calibrate inspection and battery error prevention system to ensure accurate and reliable measurement.
Built-in Probe design, surface temperature Measurement range -40~ 80 ℃, air temperature accuracy +/- 0.5 ℃, Humidity range 0~ 100% RH, providing stable and reliable dew point monitoring.
Microcomputer temperature and humidity controller, Temperature Fluctuation +/- 0.5 ℃, humidity fluctuation +/- 5% RH, with over-temperature protection, independent temperature limit alarm system to ensure safe and stable operation of the experiment.
Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H, with multi-wing air supply cycle to ensure uniform distribution, improve test reliability.
Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.
Adopt wet and dry ball or electric kiln type temperature and Humidity controller to achieve multi-stage programmable control, Temperature Uniformity +/- 2 ℃, equipped with independent temperature limit alarm system and Compressor overheating protection, built-in water Tank can be pulled out to facilitate operation and maintenance.
Sensor imported, temperature control accuracy of +/- 0.5 ℃, Humidity deviation of +/- 3% RH, equipped with independent temperature limit alarm system and test hole, to ensure safe and stable operation of the experiment.
Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.
Response Time of only 4 seconds, temperature range of -50.0 to 300 ℃, equipped with replaceable ultra-fast Response K stainless steel penetration Probe, with CAL Check ™ calibrate inspection and automatic shutdown function.