Using circulating water as the working fluid, the maximum Vacuum Level is -0.098Mpa, the pumping rate is 80L/min, the special fluid muffler reduces the noise, the double tap design can be used alone or in combination, and the ABS engineering plastic shell is resistant to corrosion.
Two-stage pump structure is equipped with PTFE material pump head, strong corrosion resistance, maximum Flow rate 125L/min, Ultimate vacuum degree 15-20mbar, no pollution and maintenance, low noise and low temperature rise.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway alarm to ensure the stability and reliability of the experimental process.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with multiple Safety protection devices including power-off protection and temperature runaway alarm to ensure the safety and stability of the experimental process.
Using PTFE pump head material and coating diaphragm, suitable for strong corrosive gases, pumping speed 20L/min, Ultimate vacuum degree 3~ 8mbar, with pressure relief and cleaning functions, good air tightness and noise less than 58dB.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with large-screen LCD display, with multiple Safety protection functions such as power-off protection and temperature alarm.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway alarm to ensure stable and reliable operation.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with multiple Safety protection devices such as power-off protection and temperature alarm to ensure stable operation of the equipment.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with large-screen LCD display and PID automatic temperature control to ensure stable and safe operation.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway alarm to ensure the stability and reliability of the experimental process.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with six safety devices such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.
Using PTFE pump head and diaphragm material, resistant to strong corrosive gases. Pumping speed 60L/min, Ultimate vacuum degree 3-8mbar, with pressure relief and cleaning functions, good air tightness, operating noise less than 58dB.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with multiple Safety protection devices including power-off protection and temperature alarm function.
The built-in vacuum pump realizes 0~ -80kPa Vacuum Level, the fully transparent vacuum Chamber can hold 12 samples, the program control supports 80 sets of paraMeter storage, and the vacuum cycle operation is automatically completed.