Gas leak detectors use sensors to detect the concentration of specific gases in the air. When the concentration exceeds the set threshold, they trigger audible and visual alarms. They are used in chemical plants, gas facilities, and other locations to monitor leaks of flammable or toxic gases, ensuring personnel safety.
Selection
When selecting, confirm the type of gas to be detected, determine the explosion-proof level and protection standard based on the usage environment, refer to the sensor lifespan and calibration cycle, check the alarm recording function and response time, and match the installation method with the power supply requirements.

Terms

Standards

Instruments

Supports 4-20mA signal input, compatible with two-wire and three-wire devices, provides 6 passive switches and RS485 interfaces, with two-level alarm settings, operating temperature 0-40 ℃, suitable for gas safety detection.

$ 212.00

Support 16 4-20mA signal input, 4.3 inch color screen display, can store 20000 alarm records, with two-level alarm and four sets of relay output, suitable for multi-point centralized control of Gas detection.

$ 259.00

Support 4-20mA/RS485 signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching quantities, two-level alarm can be freely set, suitable for gas safety detection.

$ 259.00

Support 4-20mA signal input and RS485 upload, with 2-level alarm and 2 relay output, compatible with two-wire and three-wire equipment, fast response speed and high measurement accuracy, suitable for a variety of Gas detection scenarios.

$ 140.00

Support 4-20mA signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching and sound and light alarm functions, operating temperature 0-40 ℃, suitable for a variety of Gas detection scenarios.

$ 183.00

Using Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, shell explosion-proof structure, 4-20mA standard signal output, can detect a variety of gas concentrations and have sound and light alarm function.

$ 267.00

Explosion-proof structure design, Response Time is less than 30 seconds, with 4-20mA standard signal output, can detect a variety of gas concentrations and set high and low alarm points to ensure industrial environment safety monitoring.

$ 267.00

Using Semiconductor Sensor, Response Time T90 is less than 10 seconds, detecting a variety of combustible gases, range 0~ 50% LEL, with sound and light alarm and LED large screen display.

$ 141.00

ABS + PC shell is sturdy and durable, equipped with 2.0 inch 320 * 240 resolution display screen, supports methane, O2, H2S, CO four Gas detection, Response Time is the fastest 20 seconds, battery life is 8 hours, with sound and light vibration triple Alarm mode.

$ 344.00

Support 4-20mA and RS485 signal input, compatible with two-wire and three-wire devices, provide 6 passive switching control ports, with two-level alarm setting and alarm record query function, temperature operation range 0-40 ℃.

$ 183.00

Using 8-bit micro control technology, Response Time is less than 60 seconds, equipped with 12864 point array LCD display gas concentration, with sound, light and vibration triple Alarm mode, Protection Rating up to IP65.

$ 235.00

Electrochemical sensor, Response Time less than 30 seconds, Measurement accuracy +/- 3% FS, 4-20mA standard signal output and passive relay control port, suitable for a variety of Gas detection needs.

$ 267.00

Test voltage 100-600V adjustable, short circuit current 1A +/- 0.1A, using platinum ElectRode high temperature corrosion resistance, drop height 30-40mm adjustable, time interval 30 +/- 1 seconds, automatically cut off the unqualified current.

$ 1542.00

Two-channel split design supports multi-point centralized control, with 4-20mA signal input and two-level alarm settings, microprocessor to ensure accurate monitoring, relay output can drive external equipment linkage, Operating temperature range -10~ 50 ℃.

$ 140.00

Support 8 channels of 4-20mA signal input, can store 20,000 alarm records, with two-level alarm settings and relay output, suitable for multi-point centralized control to prevent explosions and fire accidents.

$ 212.00

Articles

Sealing tester measures the pressure resistance and leakage of composite film bags.
This article introduces how to use a seal tester to evaluate the pressure resistance and leakage performance of composite film bags. The test primarily involves applying controlled pressure inside the packaging and observing pressure changes or leakage to assess the quality of the seal.
Positive pressure method seal tester evaluates packaging pressure resistance
This article introduces how the positive pressure method sealing tester evaluates the pressure resistance of packaging. The instrument simulates actual pressure conditions by injecting compressed air into the packaging and then monitors pressure changes to determine if there is any leakage.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Sealing Tester Measures Leak Points in Flexible Packaging Bags.
This article introduces how a seal tester detects air leak points in flexible packaging bags. It primarily identifies leaks through changes in pressure or vacuum, and the operation involves preparing samples, setting parameters, and conducting standardized testing.
Differential pressure method gas permeameter measures oxygen transmission rate of films.
This article introduces the method of measuring the oxygen transmission rate of films using the differential pressure gas permeation apparatus.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Sheffield Smoothness Tester for Analyzing Paper Printing Surface
This article introduces how the Sheffield smoothness tester analyzes the printing surface of paper. The instrument quantifies paper smoothness by measuring the air leakage time, with a longer time indicating a smoother surface.
Negative Pressure Method Sealing Tester for Detecting Leakage in Food Packaging
The negative pressure method seal tester creates a pressure difference inside and outside the packaging by evacuating air to detect leaks in food packaging. If there is a leak in the packaging, water will enter the packaging or produce continuous bubbles under the pressure difference, thereby determining the seal integrity. The test requires controlling parameters such as vacuum level and time, and should be conducted in accordance with relevant standards.
Principle and Application of Vacuum Decay Leak Testing Equipment
The vacuum decay leak tester is a non-destructive detection device that quantitatively detects leaks by monitoring minute pressure changes in the test chamber after vacuum evacuation.