Front temperature measurement instrument

The front furnace thermometer measures the temperature by contacting the molten metal with a thermocouple, converting thermal energy into an electrical signal to display the temperature. It is used for real-time monitoring of molten metal temperature during smelting and casting processes to prevent undercooling or overheating, which could affect the quality of the formed product.
Selection
When selecting, consider a temperature measurement range that covers process requirements, a response speed that matches the operational pace, and probe materials that withstand high-temperature corrosion. Ensure the instrument's protection rating suits the on-site environment and the calibration method facilitates routine maintenance.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Instruments

Support 4 specimens synchronous testing, folding angle 0-45 degrees adjustable, folding speed 80 +/- 5cpm, using LCD counter to achieve accurate counting, to meet the requirements of material refractive performance evaluation.

$ 2741.00

Measurement accuracy, aging resistance and long life, temperature measurement range -10 ℃~ 40 ℃, humidity measurement range 0% RH~ 90% RH.

$ 93.00

Glass transmittance measurement is facilitated by split dual-machine design, integrated UV-IR-VIS 3-in-1 test function, equipped with laser alignment to ensure measurement accuracy +/- 2%, and supports built-in lithium battery power supply.

$ 357.00

With automatic temperature compensation function to ensure accurate pH and ORP measurement in the range of -20.0 - 120.0 ℃; waterproof design to adapt to outdoor humid environment, easy to operate and economical.

$ 706.00

With 0.3~ 45m/s wide range wind speed measurement and 0~ 45 ℃ wind temperature detection capabilities, support multi-unit switching and maximum MIN Minimum recording, equipped with backlight display and low power prompt function, resolution of 0.001m/s.

$ 100.00

Platinum ElectRode ensures fast and stable measurement, supports 1-3 point calibrating and automatic temperature compensation, salinity Measurement range 0-80ppt, conductivity covers 100μS/cm to 200mS/cm, with automatic end lock and fully waterproof design.

$ 167.00

Simultaneous measurement of four paraMeters, Sampling time of only 0.4 seconds, humidity error of 2.5% +/- 1% RH, automatic recording of extreme and final values, anti-interference technology to ensure precise measurement.

$ 282.00

Using vanadium oxidation uncooled infrared focal plane Detector, temperature resolution of 0.1 ℃, with 56 ° × 42.2 ° field of view and focus-free design, support center point temperature measurement and cold hot spot automatic tracking function.

$ 428.00

Conductivity Detector measurement principle, measurement range 0-80%, resolution 0.1%, Response Time 1 second, with temperature and humidity compensation and backlight display, easy to quickly detect on site.

$ 144.00

Simultaneous measurement environment Humidity and surface temperature, accuracy of +/- 0.5 ℃, storage of 20000 readings, support for a variety of K-type Probe extended measurement, with real-time graphics display and wireless transmission function.

$ 1716.00

Measuring temperature, Humidity and dew point at the same time, dewpoint temperature range -40~ 40 ℃, with automatic memory function, digital LCD display ignore the difference, Sampling time is only 0.4 seconds, the structure is sturdy and portable.

$ 282.00

Microcomputer and anti-interference technology implementation of rapid precision measurement, temperature range -10~ 60 ℃ error +/- 0.5 ℃, humidity range 10~ 95% RH error 2.5% +/- 1%, automatic memory MAX Maximum MIN Minimum and final measurement value.

$ 299.00

With multi-range measurement function, covering the range of 0-20mS/cm, using Platinum Sensor to ensure fast and stable measurement, support 1-3 point calibrating and automatic temperature compensation, fully waterproof design for use in harsh environments.

$ 156.00

The main and auxiliary machine split design is convenient for on-site measurement, three independent test units are averaged to improve accuracy, built-in lithium battery power supply is convenient to carry, laser alignment ensures accurate measurement, Measurement accuracy +/- 2%.

$ 357.00

The equipment temperature range -40~ 70 ℃, Humidity Measurement range 20%~ 90% RH, temperature error +/- 1 ℃, using the principle of electrical change capacitance or resistance to achieve fast and accurate measurement, portable design only weighs 114g.

$ 79.00