Desktop Particle Size Analyzer

The desktop particle size analyzer measures the size distribution of particles in a sample using laser diffraction or dynamic light scattering principles. The instrument emits a laser beam through a suspension and calculates particle size based on changes in the scattering angle or intensity of light. It is used for quality control in industries such as coatings and inks, monitoring the uniformity of pigments and filler particles to ensure product stability.
Selection
When selecting, consider the measurement range covering common sample particle sizes, with precision meeting industry standards. Focus on the compatibility of the sample dispersion system with liquids or powders and the simplicity of the operation interface. Verify the instrument calibration methods, maintenance costs, and compatibility of data output formats with existing processes. Environmental adaptability, such as corrosion-resistant designs for chemical laboratories, should also be considered.
Optical inspection principle
test principle
Special purpose

Terms

Standards

Instruments

Measurement range 0.5-3000 μm, maximum resolution 0.1μm, support more than 30 image analysis functions, Particle size distribution and morphology analysis.

$ 5237.00

The image method is used to analyze the particle morphology and particle size, the test range is 1~ 3500 μ m, the system magnification is 4000 times, the automatic segmentation success rate exceeds 93%, and paraMeters such as length-diaMeter ratio and sphericity can be counted.

$ 5366.00

100L/min Sampling flow rate and six particle size channel detection, equipped with long life laser Illuminant and imported air pump, support Touchscreen operation and USB data export function.

$ 10578.00

Using 50L/min Sampling flow rate and six particle size channel synchronous detection, equipped with semiconductor laser Illuminant and Touchscreen control, built-in thermal printer supports real-time data output, Continuous Operating Time up to 5 hours.

$ 8461.00

Test range 0.5~ 3000μm, Maximum magnification 4000 times, can analyze the number of particles, area, circumference, diaMeter, aspect ratio and other distribution data, support a variety of formats of test report output.

$ 6205.00

Using light scattering principle to detect 0.3-10 μ m particle size, Sampling flow rate 28.3L/min, built-in lithium battery supports 6 hours of work, can directly save data to U disk, equipped with thermal printer for on-site output.

$ 3922.00

With six-channel particle size detection and 2.83L/min Sampling flow rate, using laser Illuminant life of over 30,000 hours, support UCL calculation and Built-in Printer, AC-DC dual-use can work continuously for more than 6 hours.

$ 848.00

With 6-channel synchronous detection capability, maximum sampling concentration of 35000 pcs/L, using semiconductor laser Illuminant life of 10 years, built-in battery life of more than 5 hours and support data export printing.

$ 1501.00

With six-channel particle size detection capability, Sampling flow rate 2.83L/min, using long-life laser Illuminant to ensure Stability, built-in thermal printer and support AC and DC power supply, can work continuously for more than 6 hours.

$ 1171.00

Explosion-proof enclosure design ensures stable operation in harsh environments, can simultaneously monitor multiple particle size dust concentration without changing the cutter, Measurement range 0.01-100 mg/m ³, built-in protective gas curtain to prevent Optical inspection system contamination.

$ 5043.00

Image segmentation technology is used to process overlapping dust and maintain particle prototype; Measurement range is 0.1~ 3000μm, repeatability error ≤ +/- 1%; support custom particle size classification and various image processing methods.

$ 9998.00

With six particle size channel detection capability, sampling capacity of 2.83L/min, built-in lithium battery supports 6 hours of continuous operation, using semiconductor laser Illuminant and color Touchscreen design.

$ 2510.00

The image method is used for particle morphology analysis, the measurement range is 0.1~ 3000μm, the total magnification is 8000 times, and the automatic segmentation and measurement of various geometric paraMeters are supported, and the operation is efficient.

$ 8949.00

Made of hardened stainless steel with an accuracy of 2μm, with a range of 0 to 5000μm and a groove length of 120mm, to ensure the accuracy and durability of particle size measurement.

$ 2442.00

Spreader accuracy of +/- 0.05mm, Spreader thickness range of 0~ 10mm, coating speed 5~ 180mm/s adjustable, support automatic feeding and UV solid content and other customized functions to meet the needs of laboratory precision Moulding.

$ 8142.00

Articles

How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Laser particle size analyzer measures the particle size distribution of spray powder.
Laser particle size analyzers measure the particle size distribution of sprayed powder based on the principle of light scattering, which is critical for coating uniformity and adhesion. During measurement, the powder must be dispersed in a suitable medium to avoid agglomeration, and tests should be repeated to ensure accuracy.
Operating Specifications and Result Interpretation of Paint Fineness Gauges
The fineness gauge is used to measure the dispersion of particles in paint. During operation, the sample should be applied to the groove under standard conditions, and a scraper is used to spread it evenly to form a wet film. The particle visibility is then observed under appropriate lighting, and the fineness value is read from the corresponding scale.
Laser particle size analyzer analyzes particle size distribution of paint pigments.
This article introduces the application of laser particle size analyzers in analyzing the particle size distribution of paint pigments. It mentions that the particle size distribution of pigments affects the optical properties, stability, and rheological characteristics of coatings.
Blue-style grinder achieves efficient grinding of ink fineness.
The basket mill is a type of wet grinding equipment used in fine chemical fields such as ink production. It utilizes a high-speed rotating impeller to drive grinding media, generating shear and impact forces on the slurry, thereby dispersing pigment particles and reducing their fineness.
Application of High-Speed Disperser in the Preparation of Water-Based Inks
This article introduces the application of a high-speed disperser in the preparation of water-based inks. It first explains the working principle of the equipment, which involves generating shear forces through high-speed rotation to disperse particles.
Ink fineness gauge measures the dispersion degree of pigment particles.
The fineness of grind gauge is a method used to evaluate the dispersion level of pigment particles in ink.
Which is more accurate for measurement: the scattering method or the transmission method in turbidimeters?
The article compares two methods for measuring turbidity: the scattering method and the transmission method. The choice of method depends on the turbidity range of the sample, particle characteristics, and measurement standards. Both methods have their respective applicable scenarios, and accuracy depends on the actual application conditions.
Core Differences and Selection Guide for Pulpers and Refiners
Both the beater and the refiner are equipment for processing materials, but their core functions differ. When selecting the appropriate machine, it should be based on the characteristics of the material: choose a beater for fiber treatment and a refiner for particle refinement, while also taking into account process requirements and operational costs.
Sieve Residue Analyzer and Sieve Analysis for Determining Pigment Particle Size Distribution
This article introduces how the sieve residue analyzer measures the particle size distribution of pigments through mechanical sieving.
Scraper Fineness Gauge for Determining the Fineness of Paste Inks
The Scraper Fineness Gauge is used to measure the dispersion degree of pigment particles in products such as paste inks. Its principle involves scraping a film on a scraper plate with wedge-shaped grooves and observing the scale at which particles appear to assess the fineness, with the result expressed in micrometers.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Porosity Control in the Preparation of Porous Coatings During the Blade Coating Process
Doctor blade coating is a wet coating technique widely used for preparing functional coatings, which involves uniformly applying a slurry containing solid particles (such as ceramics, polymers, or metal oxides) onto a substrate, followed by drying and heat treatment to form the coating.
The main issue with using a Ubbelohde viscometer is that 90% of capillary blockages are caused by inadequate sample filtration.
More than 90% of capillary blockage in Ubbelohde viscometers during measurement is due to inadequate sample filtration. Minute particles or gels in the sample tend to adhere to or become trapped when flowing through the narrow capillary, leading to abnormal flow rates and affecting measurement accuracy.