Dyeing Lens Chromatic Aberration Measuring Instrument

The dye lens color difference measuring instrument captures the color data of lenses through optical sensors, compares and analyzes the color difference with standard color samples. It is used to detect the color consistency of dyed lenses, ensuring products meet specifications, and is applied in eyewear manufacturing and quality control processes.

Instruments

The minimum test aperture is 0.5mm, and the three Illuminants share a test hole. Three transmittance data of 550nm, 850nm and 940nm can be obtained for one hole. Real-time dynamic self-Adjustment, Test accuracy +/- 2%.

$ 538.00

Optical inspection system with infinity, equipped with 4X-100X flat field color difference elimination objective lens and WF10X-16X large field of view eyepiece, providing NA1.25 condenser lens and 0.001mm fine-tuning accuracy, support phase contrast observation function, comfortable and convenient operation.

$ 1913.00

Using long working distance flat field color difference elimination objective lens and insert plate phase contrast condenser lens, working distance 30mm, support double-decked mechanical moving stage, adapt to a variety of culture dishes, easy to dynamic microscopic observation and comfortable operation.

$ 2462.00

Dual lens design can switch the viewing direction arbitrarily, equipped with 450,000 pixels and 70 ° field of view, deep tube with anti-corrosion and wear-resistant material, support for photography and video and built-in 8GB storage, battery life of 3-4 hours.

$ 4721.00

Equipped with infinity flat field color difference elimination objective lens and large field of view eyepiece to provide high-quality Optical Properties; using 3W LED cold Illuminant lighting and coaxial coarse fine-tuning system, the fine-tuning grid value reaches 0.001mm, and the operation is comfortable and accurate.

$ 1977.00

Using 60cpm Friction Frequency and 9N Friction Load, the specified number of times of friction can be carried out through the friction head of parcel white cotton cloth, and the sample dyeing Stability can be evaluated according to the gray card comparison.

$ 524.00

Equipped with a long working distance flat-field color difference elimination objective lens and four sets of fluorescence filters, it supports phase contrast observation and fluorescence switching, and the fretting grid value is up to 2 μm, which is suitable for clear imagery of living cells and liquid samples.

$ 10207.00

Optical inspection system with infinity, equipped with 4X-100X flat-field color difference elimination objective lens and WF10X large-field eyepiece, providing 2 μm fretting grid value coaxial focusing system, double-decked mechanical stage moving range of 75 × 50mm.

$ 1913.00

Using 3-in-1 optical path design, one hole can simultaneously measure three wavelengths transmittance. Equipped with 1mm test aperture and Automatic calibration function, support 850nm/940nm infrared and 550nm visible light measurement, accuracy of +/- 2%.

$ 373.00

The dual-station design can simultaneously carry out two sample tests, the friction speed is 30CPM, the friction hammer load is 200g, and it has the power-off memory function to support dry and wet friction and organic solvent friction test.

$ 1053.00

Using reciprocating friction method, friction load 9N, Frequency 60cpm, can be set 0~ 999900 times test, support drying wet white cotton cloth for dyeing fastness evaluation.

$ 1413.00

Illuminant continuous luminance adjustment, equipped with coaxial coarse fretting focusing mechanism, fine-tuning accuracy of 0.002mm, support 40X-1600X magnification range observation, lens barrel can rotate 360 degrees freely.

$ 298.00

Measurement accuracy of +/- 5.0 + L/100μm with 20 million pixel high definition CCD and bilateral telecentric lens, supports automatic identification of multiple workpieces for simultaneous measurement without positioning fixture.

$ 17227.00

With transparent reflection lighting switching function, configure center adjustable non-stress objective lens and rotating stage, fretting grid value 2 μ m, table vertical Travel 30mm, support orthogonal and cone light observation.

$ 3268.00

Automatic image registration does not need to locate the workpiece, can identify multiple measurement pieces at the same time, repeability accuracy 0.001mm, Measurement accuracy +/- 5.0 + L/100μm, equipped with high definition 20 million pixel CCD and bilateral telecentric lens.

$ 15008.00

Articles

The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Colorimeter controls batch color difference in plastic and rubber films.
This article primarily discusses how to use a colorimeter to control color differences in the production of plastic and rubber films. It explains the working principle of the colorimeter, which involves converting colors into numerical values represented by L, a, and b values, and then calculating the color difference.
Colorimeter evaluates the change in yellowing index of transparent resin.
This article introduces how to use a colorimeter to measure the yellowing index changes in transparent resin. Transparent resin can turn yellow over time or due to environmental influences, and the yellowing index can quantify the degree of color change.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
Reflectometer for measuring the hiding power of colored paint coatings
This article introduces the method of using a reflectometer to measure the hiding power of colored paint coatings. Hiding power refers to the ability of a coating to conceal differences in the underlying color. Traditional methods relying on visual judgment are prone to subjective influences, while instrumental measurement offers greater objectivity and accuracy.
Application of Colorimeters in Color Management for Packaging and Printing
This article mainly discusses the application of colorimeters in color management for packaging and printing. A colorimeter is an instrument used to measure color, capable of converting colors into numerical values, such as representing them with L*a*b* values.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.
Application of Colorimeters in Controlling Color Differences in Paint Batches
This article introduces the role of colorimeters in controlling color consistency in paint production. Since human judgment of color is easily influenced by lighting and subjective factors, colorimeters quantify color differences in the CIELAB color space by measuring spectral data, providing an objective basis for production.
Application of Colorimeter and Color Matching Box in Pigment Color Inspection
A colorimeter and a light booth are two primary tools in pigment color inspection. The colorimeter measures color through photoelectric principles, while the light booth provides a standardized light source environment for visual evaluation of color effects, metamerism, and other phenomena.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.