Water Purifier for Laboratory Use

The laboratory water purification system removes impurities from water, including particulates, ions, and organic matter, through multi-stage filtration and purification technologies. The process involves steps such as pre-treatment, reverse osmosis, ion exchange, and ultrafiltration to ensure water quality meets experimental requirements. It is used for laboratory analysis, reagent preparation, and instrument cleaning, ensuring accurate and reliable test results.
Selection
When selecting a water purification system, consider water quality standards, water consumption, and application scenarios. Determine the required water purity level based on experimental needs, such as ultrapure water or deionized water. Evaluate the system's water production rate, maintenance costs, and frequency of consumable replacement. Check the system's stability and ease of operation to ensure compatibility with existing laboratory conditions.

Terms

Standards

Instruments

Flow velocity 1.5L/min, reverse osmosis (RO) membrane and purification column are used to remove trace ions efficiently, and intelligent microcomputer control realizes automatic operation and online water quality monitoring.

$ 2784.00

Flow velocity 1.5L/min, reverse osmosis (RO) membrane and purification column, intelligent microcomputer control to achieve automatic operation and online water quality monitoring, effective removal of trace ions.

$ 3430.00

The water pRoduction rate reaches 5L/h, the water intake Flow velocity is 0.8L/min, and the RO membrane intelligent anti-scale flushing and automatic domestic circulation system are supported to ensure the stability of ultrapure water quality, which is suitable for a variety of experimental needs.

$ 1897.00

The water pRoduction rate reaches 10L/h, the water intake Flow velocity is 1.0L/min, and the RO membrane intelligent anti-scale washing and automatic domestic circulation system are used to ensure stable water quality and meet the high standard requirements of the laboratory.

$ 2300.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

Water and oil dual-use supports room temperature to 100 ° C, capacity 5L, Temperature Uniformity +/- 0.05 ° C, with domestic circulation system to avoid heat effects, external circulation to establish a second thermostatic field, Safety protection includes power failure and low water level alarm.

$ 435.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, Temperature control accuracy 0.01 ℃, Built-in High Accuracy PT100 Sensor, support external circulation and domestic circulation system, ensure that the flow field and temperature field in the Tank are highly uniform.

$ 869.00

With water and oil dual-use function, Temperature Uniformity +/- 0.05 ℃, Temperature range from room temperature to 200 ℃, domestic circulation system adopts no heat centrifugal pump to avoid affecting the temperature field, support external circulation to establish a second thermostatic field.

$ 924.00

Temperature control accuracy of +/- 0.05 ℃, support room temperature to 300 ℃ range of water and oil dual-use, equipped with high temperature centrifugal pump head 5 Meters, domestic circulation system to achieve uniform temperature field.

$ 825.00

The equipment supports water and oil dual-use, Temperature range from room temperature to 300 ℃, capacity 40L, using PID automatic temperature control and High Accuracy PT100 Sensor to ensure stable and uniform temperature, with domestic circulation system to avoid heat impact, Safety protection function is complete.

$ 1148.00

Temperature range room temperature to 300 ℃, Temperature Fluctuation +/- 0.05 ℃, the use of non-heat centrifugal circulation pump to avoid their own heat impact temperature field, with low water level protection and alarm function.

$ 2061.00

Temperature range Room temperature to 300 ℃, Temperature Fluctuation +/- 0.05 ℃, support water-oil dual-use medium; High temperature centrifugal pump head 5 Meters, to achieve uniform temperature field inside and outside circulation, built-in multiple Safety protection devices.

$ 1166.00

Water and oil dual-use Temperature range Room temperature to 200 ℃, Temperature Uniformity +/- 0.05 ℃, with internal and external circulation system and multiple Safety protection, the use of heat-free centrifugal pump to avoid affecting the temperature field uniformity.

$ 761.00

With dual-use function of water and oil, Temperature Uniformity up to +/- 0.05 ℃, Flow rate of external circulation pump 6L/min, liner with S304 stainless steel, Safety protection including power failure and low water level alarm.

$ 816.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

Articles

Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
UV aging test chamber for evaluating the discoloration degree of resin weather resistance
This article introduces the method of using a UV aging test chamber to examine the degree of weather-induced discoloration in resins.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.
Standards and Equipment Selection for Drop Testing in Mobile Phone Whole-Machine Reliability Testing
Drop test is an important method to test the durability of mobile phones, simulating accidental drops in daily life to examine the impact resistance of components such as the casing and screen. The test must follow international or industry standards, specifying conditions such as drop height and number of times.
Application of Colorimeter and Color Matching Box in Pigment Color Inspection
A colorimeter and a light booth are two primary tools in pigment color inspection. The colorimeter measures color through photoelectric principles, while the light booth provides a standardized light source environment for visual evaluation of color effects, metamerism, and other phenomena.
Analyzing Packaging Design Defects through Drop Tester Selection
This article discusses how the selection of a drop tester during the packaging design process can actually reveal many design issues early on. For example, determining parameters such as drop height, testing standards, and equipment dimensions during the selection process inherently tests the reasonableness of the design.
The rain test chamber simulates heavy rain environments to test the waterproof sealing performance of products.
A rain test chamber is a device that simulates rainfall environments, used to evaluate the waterproof performance of product casings or sealed components. It tests electronic products, automotive parts, and other items in accordance with relevant standards by controlling water flow, water pressure, and spray duration.
Application of Damp Heat Testing in the Environmental Adaptability Verification of Automotive Components
Humidity and heat testing is an accelerated test method that simulates high-temperature and high-humidity environments, used to evaluate the performance changes of automotive components under humid conditions. It primarily examines the insulation and corrosion resistance capabilities of electrical and electronic components, the aging resistance of interior materials, and the corrosion prevention effectiveness of exterior structural parts.