Low Temperature Thermostatic Circulation Bath

The low-temperature constant temperature circulation bath reduces the liquid temperature through a refrigeration system and, in combination with a circulation pump, maintains a uniform and constant low temperature for the liquid inside the bath. It is used in scenarios such as laboratory sample cooling and reactor temperature control to ensure stable testing conditions.
Selection
When selecting, consider that the temperature range must cover experimental needs, the temperature control accuracy matches sample sensitivity, the tank capacity accommodates container sizes, and pay attention to cooling power and heat dissipation requirements, as well as interface compatibility with existing equipment.

Terms

Standards

Instruments

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Adopting 5 inch Touchscreen integrated display, PID intelligent temperature control technology automatically sets paraMeters, Compressor unit cooling and cooling quickly, domestic circulation makes the temperature uniform, external circulation can establish external thermostatic field, slot volume 6L.

$ 985.00

Temperature range of -25~ 200 ℃ and +/- 0.01 ℃ high resolution, support internal and external circulation and horizontal and vertical two-way mixing, equipped with low level protection and Pt100 temperature sensor, suitable for multi-sample thermostatic testing needs.

$ 1752.00

With dual functions of internal and external circulation, Temperature Fluctuation ≤ +/- 0.2 ℃, resolution 0.1 ℃, pump flow rate 6L/min, to ensure temperature uniformity, support connection with external equipment.

$ 306.00

With heating and cooling function, Temperature range -10~ 150 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, Pump Flow rate 12L/min, Support internal and external circulation and remote communication, corrosion resistant design.

$ 974.00

With dual functions of internal and external circulation, Temperature Fluctuation ≤ +/- 0.2 ℃, volume 20L, pump flow 6L/min, improve temperature uniformity and accuracy, suitable for connecting a variety of experimental equipment.

$ 330.00

The use of domestic circulation to ensure uniform and constant temperature, external circulation pump can lead the liquid outside the Tank heating, temperature control accuracy +/- 0.1 ℃, Temperature Fluctuation +/- 1 ℃, LED dual window digital display, insulation layer efficient, Benchtop structure small size.

$ 1080.00

Temperature range -30~ 100 ℃, temperature resolution 0.1 ℃, fully enclosed Compressor refrigeration and overheating overcurrent protection, stainless steel liner for easy cleaning, equipped with high-performance heat-free centrifugal circulation pump.

$ 1493.00

Adopt fully enclosed Compressor refrigeration system, Temperature range -10~ 100 ℃, temperature resolution 0.1 ℃, equipped with non-heat centrifugal circulation pump and overheating overcurrent protection, the side plate can be flexibly disassembled for easy maintenance.

$ 1442.00

Temperature control accuracy of +/- 0.1 ℃, temperature fluctuation of +/- 1 ℃, equipped with domestic circulation to ensure uniform temperature, external circulation pump can lead liquid heating, LED double window digital display easy to operate, thermal insulation material efficient, Benchtop compact structure.

$ 911.00

Temperature range -10~ 100 ℃, temperature control accuracy +/- 0.2 ℃, support multi-stage programming and internal and external circulation, provide over-temperature and low temperature sound and light alarm and liquid level protection.

$ 1450.00

Microcomputer temperature control self-tuning PID adjustment technology, temperature control accuracy of +/- 0.05 ℃, Temperature Fluctuation is small; with internal and external circulation function, pump Flow rate 10L/min, support external system thermostatic control; fully enclosed Compressor refrigeration, low noise efficiency.

$ 4064.00

Using PT100 platinum resistance imported from Japan to measure temperature, the fully enclosed Compressor has low operating noise and high cooling efficiency, Temperature Fluctuation +/- 0.1 ℃, supports internal and external circulation and 4L/min pump Flow rate, stable and reliable temperature control.

$ 948.00

It adopts transparent carbonic acid ester Bath design, with a volume of 6L, equipped with pressure/suction pump and Pt100 temperature sensor, with low liquid level protection and hardware over-temperature protection functions, and supports external circulation temperature control.

$ 1519.00

Water and oil dual-use optional room temperature to 100 ℃ range, external circulation function to establish a second thermostatic field, Temperature Uniformity +/- 0.05 ℃, domestic circulation without heat centrifugal pump to avoid the impact of temperature field, Safety protection including power failure and low water level alarm.

$ 1058.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.